H.B. 310

             1     

CONSTRUCTION CODE AMENDMENTS

             2     
2013 GENERAL SESSION

             3     
STATE OF UTAH

             4     
Chief Sponsor: Brad R. Wilson

             5     
Senate Sponsor: Curtis S. Bramble

             6     
             7      LONG TITLE
             8      General Description:
             9          This bill modifies the State Construction Code.
             10      Highlighted Provisions:
             11          This bill:
             12          .    adopts the 2012 edition of certain nationally recognized building codes;
             13          .    modifies certain statewide amendments to the State Construction Code; and
             14          .    repeals certain local amendments to the State Construction Code.
             15      Money Appropriated in this Bill:
             16          None
             17      Other Special Clauses:
             18          This bill takes effect on July 1, 2013.
             19      Utah Code Sections Affected:
             20      AMENDS:
             21          15A-2-103, as last amended by Laws of Utah 2012, Chapter 76
             22          15A-2-104, as enacted by Laws of Utah 2011, Chapter 14
             23          15A-3-102, as enacted by Laws of Utah 2011, Chapter 14
             24          15A-3-103, as enacted by Laws of Utah 2011, Chapter 14
             25          15A-3-104, as enacted by Laws of Utah 2011, Chapter 14
             26          15A-3-105, as enacted by Laws of Utah 2011, Chapter 14
             27          15A-3-107, as enacted by Laws of Utah 2011, Chapter 14


             28          15A-3-108, as last amended by Laws of Utah 2012, Chapter 76
             29          15A-3-110, as enacted by Laws of Utah 2011, Chapter 14
             30          15A-3-112, as enacted by Laws of Utah 2011, Chapter 14
             31          15A-3-113, as last amended by Laws of Utah 2012, Chapters 76 and 219
             32          15A-3-202, as last amended by Laws of Utah 2012, Chapter 62
             33          15A-3-204, as enacted by Laws of Utah 2011, Chapter 14
             34          15A-3-205, as enacted by Laws of Utah 2011, Chapter 14
             35          15A-3-206, as enacted by Laws of Utah 2011, Chapter 14
             36          15A-3-302, as enacted by Laws of Utah 2011, Chapter 14
             37          15A-3-303, as enacted by Laws of Utah 2011, Chapter 14
             38          15A-3-304, as enacted by Laws of Utah 2011, Chapter 14
             39          15A-3-305, as enacted by Laws of Utah 2011, Chapter 14
             40          15A-3-306, as enacted by Laws of Utah 2011, Chapter 14
             41          15A-3-307, as enacted by Laws of Utah 2011, Chapter 14
             42          15A-3-308, as enacted by Laws of Utah 2011, Chapter 14
             43          15A-3-309, as enacted by Laws of Utah 2011, Chapter 14
             44          15A-3-310, as enacted by Laws of Utah 2011, Chapter 14
             45          15A-3-313, as enacted by Laws of Utah 2011, Chapter 14
             46          15A-3-314, as enacted by Laws of Utah 2011, Chapter 14
             47          15A-3-401, as enacted by Laws of Utah 2011, Chapter 14
             48          15A-3-501, as enacted by Laws of Utah 2011, Chapter 14
             49          15A-3-601, as last amended by Laws of Utah 2012, Chapter 76
             50          15A-3-801, as enacted by Laws of Utah 2011, Chapter 14
             51      REPEALS:
             52          15A-4-302, as enacted by Laws of Utah 2011, Chapter 14
             53          15A-4-304, as enacted by Laws of Utah 2012, Chapter 76
             54          15A-4-305, as enacted by Laws of Utah 2012, Chapter 76
             55          15A-4-306, as enacted by Laws of Utah 2012, Chapter 76
             56          15A-4-307, as enacted by Laws of Utah 2012, Chapter 76
             57     
             58      Be it enacted by the Legislature of the state of Utah:


             59          Section 1. Section 15A-2-103 is amended to read:
             60     
CHAPTER 2. ADOPTION OF STATE CONSTRUCTION CODE

             61     
Part 1. General Provisions

             62           15A-2-103. Specific editions adopted of construction code of a nationally
             63      recognized code authority.
             64          (1) Subject to the other provisions of this part, the following construction codes are
             65      incorporated by reference, and together with the amendments specified in Chapter 3, Statewide
             66      Amendments to International Plumbing Code, and Chapter 4, Local Amendments Incorporated
             67      as Part of State Construction Code, are the construction standards to be applied to building
             68      construction, alteration, remodeling, and repair, and in the regulation of building construction,
             69      alteration, remodeling, and repair in the state:
             70          (a) the [2009] 2012 edition of the International Building Code, including Appendix J,
             71      issued by the International Code Council;
             72          (b) the [2009] 2012 edition of the International Residential Code, issued by the
             73      International Code Council;
             74          (c) the [2009] 2012 edition of the International Plumbing Code, issued by the
             75      International Code Council;
             76          (d) the [2009] 2012 edition of the International Mechanical Code, issued by the
             77      International Code Council;
             78          (e) the [2009] 2012 edition of the International Fuel Gas Code, issued by the
             79      International Code Council;
             80          (f) the 2011 edition of the National Electrical Code, issued by the National Fire
             81      Protection Association;
             82          (g) the 2009 edition of the International Energy Conservation Code, issued by the
             83      International Code Council;
             84          (h) subject to Subsection 15A-2-104 (2), the HUD Code;
             85          (i) subject to Subsection 15A-2-104 (1), Appendix E of the [2009] 2012 edition of the
             86      International Residential Code, issued by the International Code Council; and
             87          (j) subject to Subsection 15A-2-104 (1), the 2005 edition of the NFPA 225 Model
             88      Manufactured Home Installation Standard, issued by the National Fire Protection Association.
             89          (2) Consistent with Title 65A, Chapter 8, Management of Forest Lands and Fire


             90      Control, the Legislature adopts the 2006 edition of the Utah Wildland Urban Interface Code,
             91      issued by the International Code Council, with the alternatives or amendments approved by the
             92      Utah Division of Forestry, as a construction code that may be adopted by a local compliance
             93      agency by local ordinance or other similar action as a local amendment to the codes listed in
             94      this section.
             95          Section 2. Section 15A-2-104 is amended to read:
             96           15A-2-104. Installation standards for manufactured housing.
             97          (1) The following are the installation standards for manufactured housing for new
             98      installations or for existing manufactured or mobile homes that are subject to relocation,
             99      building alteration, remodeling, or rehabilitation in the state:
             100          (a) The manufacturer's installation instruction for the model being installed is the
             101      primary standard.
             102          (b) If the manufacturer's installation instruction for the model being installed is not
             103      available or is incomplete, the following standards apply:
             104          (i) Appendix E of the [2009] 2012 edition of the IRC, as issued by the International
             105      Code Council for installations defined in Section AE101 of Appendix E; or
             106          (ii) if an installation is beyond the scope of the [2009] 2012 edition of the IRC as
             107      defined in Section AE101 of Appendix E, the 2005 edition of the NFPA 225 Model
             108      Manufactured Home Installation Standard, issued by the National Fire Protection Association.
             109          (c) A manufacturer, dealer, or homeowner is permitted to design for unusual
             110      installation of a manufactured home not provided for in the manufacturer's standard installation
             111      instruction, Appendix E of the [2009] 2012 edition of the IRC, or the 2005 edition of the
             112      NFPA 225, if the design is approved in writing by a professional engineer or architect licensed
             113      in Utah.
             114          (d) For a mobile home built before June 15, 1976, the mobile home shall also comply
             115      with the additional installation and safety requirements specified in Chapter 3, Part 8,
             116      Installation and Safety Requirements for Mobile Homes Built Before June 15, 1976.
             117          (2) Pursuant to the HUD Code Section 604(d), a manufactured home may be installed
             118      in the state that does not meet the local snow load requirements as specified in Chapter 3, Part
             119      2, Statewide Amendments to IRC, except that the manufactured home shall have a protective
             120      structure built over the home that meets the IRC and the snow load requirements under Chapter


             121      3, Part 2, Statewide Amendments to IRC.
             122          Section 3. Section 15A-3-102 is amended to read:
             123     
CHAPTER 3. STATEWIDE AMENDMENTS INCORPORATED AS PART OF STATE

             124     
CONSTRUCTION CODE

             125     
Part 1. Statewide Amendments to IBC

             126           15A-3-102. Amendments to Chapters 1 through 3 of IBC.
             127          (1) IBC, Section 106, is deleted.
             128          (2) (a) In IBC, Section 110, a new section is added as follows: "110.3.5,
             129      Weather-resistant exterior wall envelope. An inspection shall be made of the weather-resistant
             130      exterior wall envelope as required by Section 1403.2, and flashing as required by Section
             131      1405.4 to prevent water from entering the weather-resistive barrier."
             132          (b) The remaining sections of IBC, Section 110, are renumbered as follows: 110.3.6,
             133      Lath or gypsum board inspection; 110.3.7, Fire- and smoke-resistant penetrations; 110.3.8,
             134      Energy efficiency inspections; 110.3.9, Other inspections; 110.3.10, Special inspections; and
             135      110.3.11, Final inspection.
             136          (3) IBC, Section 115.1, is deleted and replaced with the following: "115.1 Authority.
             137      Whenever the building official finds any work regulated by this code being performed in a
             138      manner either contrary to the provisions of this code or other pertinent laws or ordinances or is
             139      dangerous or unsafe, the building official is authorized to stop work."
             140          (4) In IBC, Section 202, the [definition for "Assisted Living Facility" is deleted and
             141      replaced with the following: "ASSISTED LIVING FACILITY. See Section 308.1.1.]
             142      following definition is added for Ambulatory Surgical Center: "AMBULATORY SURGICAL
             143      CENTER. A building or portion of a building licensed by the Utah Department of Health
             144      where procedures are performed that may render patients incapable of self preservation where
             145      care is less than 24 hours. See Utah Administrative Code R432-13."
             146          (5) In IBC, Section 202, the definition for ["Child Care Facilities" is deleted and
             147      replaced with the following: "CHILD CARE FACILITIES. See Section 308.3.1."] Foster Care
             148      Facilities is modified by changing the word "Foster" to "Child."
             149          (6) In IBC, Section 202, the definition for "[F]Record Drawings" is modified by
             150      deleting the words "a fire alarm system" and replacing them with "any fire protection system".
             151          (7) In IBC, Section 202, the following definition is added for Residential


             152      Treatment/Support Assisted Living Facility: "RESIDENTIAL TREATMENT/SUPPORT
             153      ASSISTED LIVING FACILITY. See Section 308.1.2."
             154          (8) In IBC, Section 202, the following definition is added for Type I Assisted Living
             155      Facility: "TYPE I ASSISTED LIVING FACILITY. See Section 308.1.2."
             156          (9) In IBC, Section 202, the following definition is added for Type II Assisted Living
             157      Facility: "TYPE II ASSISTED LIVING FACILITY. See Section 308.1.2."
             158          [(6)] (10) In the list in IBC, Section 304.1, the following words are added after the
             159      words "Ambulatory [health] care facilities" [is deleted and replaced with "Ambulatory health
             160      care facilities with four or fewer surgical operating rooms."]: "where four or more care
             161      recipients are rendered incapable of self preservation."
             162          [(7)] (11) In IBC, Section 305.2, [is deleted and replaced with the following: "305.2
             163      Day care. The use of a building or structure, or portion thereof, for educational, supervision,
             164      child day care centers, or personal care services of more than four children shall be classified as
             165      a Group E occupancy. See Section 424 for special requirements for Group E child day care
             166      centers.] the words "child care centers," are inserted after the word "supervision," and the
             167      following sentence is added at the end of the paragraph: "See Section 425 for special
             168      requirements for Day Care."
             169      [Exception: Areas used for child day care purposes with a Residential Certificate or a Family
             170      License, as defined in Utah Administrative Code, R430-90, Licensed Family Child Care, may
             171      be located in a Group R-2 or R-3 occupancy as provided in Section 310.1 or shall comply with
             172      the International Residential Code in accordance with Section 101.2. Areas used for Hourly
             173      Child Care Centers, as defined in Utah Administrative Code, R430-60, or Out of School Time
             174      Programs, as defined in Utah Administrative Code, R430-70, may be classified as accessory
             175      occupancies."]
             176          [(8) In IBC, Section 308, the following definitions are added: "308.1.1 Definitions. The
             177      following words and terms shall, for the purposes of this section and as used elsewhere in this
             178      code, have the meanings shown herein.]
             179          (12) In IBC, Section 305.2.2 and 305.2.3, the word "five" is deleted and replaced with
             180      the word "four" in both places.
             181          (13) A new IBC Section 305.2.4 is added as follows: "305.2.4 Child Day Care --
             182      Residential Certificate or a Family License. Areas used for child day care purposes with a


             183      Residential Certificate R430-50 or a Family License, as defined in Utah Administrative Code,
             184      R430-90, Licensed Family Child Care, may be located in a Group R-2 or R-3 occupancy as
             185      provided in Section 310.5 or shall comply with the International Residential Code in
             186      accordance with Section R101.2."
             187          (14) A new IBC Section 305.2.5 is added as follows: "305.2.5 Child Care Centers.
             188      Areas used for Hourly Child Care Centers, as defined in Utah Administrative Code, R430-60,
             189      Child Care Center as defined in Utah Administrative Code, R430-100, or Out of School Time
             190      Programs, as defined in Utah Administrative Code, R430-70, may be classified as accessory
             191      occupancies."
             192          (15) A new IBC Section 308.2.1 is added as follows: "308.2.1 Assisted living facilities
             193      and related occupancies. The following words and terms shall, for the purposes of this section
             194      and as used elsewhere in this code, have the meanings shown herein.
             195      TYPE I ASSISTED LIVING FACILITY. A residential facility licensed by the Utah
             196      Department of Health that provides a protected living arrangement for ambulatory,
             197      non-restrained persons who are capable of achieving mobility sufficient to exit the facility
             198      without the assistance of another person.
             199      Occupancies. Limited capacity, type I assisted living facilities with two to five residents shall
             200      be classified as R-3 occupancies. Small, type I assisted living facilities with six to sixteen
             201      residents shall be classified as R-4 occupancies. Large, type I assisted living facilities with
             202      over sixteen residents shall be classified as I-1 occupancies.
             203      TYPE II ASSISTED LIVING FACILITY. A residential facility licensed by the Utah
             204      Department of Health that provides an array of coordinated supportive personal and health care
             205      services to residents who meet the definition of semi-independent.
             206      Semi-Independent. A person who is:
             207      A. Physically disabled but able to direct his or her own care; or
             208      B. Cognitively impaired or physically disabled but able to evacuate from the facility with the
             209      physical assistance of one person.
             210      Occupancies. Limited capacity, type II assisted living facilities with two to five residents shall
             211      be classified as R-4 occupancies. Small, type II assisted living facilities with six to sixteen
             212      residents shall be classified as I-1 occupancies. Large, type II assisted living facilities with
             213      over sixteen residents shall be classified as I-2 occupancies.


             214      RESIDENTIAL TREATMENT/SUPPORT ASSISTED LIVING FACILITY. A residential
             215      treatment/support assisted living facility which creates a group living environment for four or
             216      more residents licensed by the Utah Department of Human Services, and provides a protected
             217      living arrangement for ambulatory, non-restrained persons who are capable of achieving
             218      mobility sufficient to exit the facility without the physical assistance of another person."
             219          [(9) In IBC, Section 308.2, the words "Assisted living facilities" are deleted and
             220      replaced with "Type I Assisted living facilities."]
             221          [(10)] (16) In IBC, Section 308.3, [is deleted and replaced with the following: "308.3
             222      Group I-2. This occupancy shall include buildings and structures used for medical, surgical,
             223      psychiatric, nursing, or custodial care on a 24-hour basis of more than three persons who are
             224      not capable of self-preservation. This group shall include, but not be limited to the following:
             225      hospitals, nursing homes (both intermediate care facilities and skilled nursing facilities), mental
             226      hospitals, detoxification facilities, ambulatory surgical centers with five or more operating
             227      rooms where care is less than 24 hours, and type II assisted living facilities. Type II assisted
             228      living facilities with five or fewer persons shall be classified as a Group R-4. Type II assisted
             229      living facilities as defined in 308.1.1 with at least six and not more than sixteen residents shall
             230      be classified as a Group I-1 facility."] the words "(see Section 308.2.1)" are added after the
             231      words "assisted living facilities".
             232          [(11)] (17) In IBC, Section 308.3.1, [the definition for "CHILD CARE FACILITIES" is
             233      deleted and replaced with the following: "CHILD CARE FACILITIES. A child care facility, as
             234      licensed by the Utah Department of Human Services in Utah Administrative Code, R501, that
             235      provides care on a 24-hour basis to more than four children 2 1/2 years of age or less shall be
             236      classified as Group I-2."] all of the words after the first International Residential Code are
             237      deleted.
             238          [(12) IBC, Section 308.5, is deleted and replaced with the following: "308.5 Group I-4,
             239      day care facilities. This group shall include buildings and structures occupied by persons of
             240      any age who receive custodial care less than 24 hours by individuals other than parents or
             241      guardians, relatives by blood, marriage, or adoption, and in a place other than the home of the
             242      person cared for. A facility such as the above with four or fewer persons shall be classified as
             243      an R-3 or shall comply with the International Residential Code in accordance with Section
             244      101.2. Places of worship during religious functions and Group E child day care centers are not


             245      included."]
             246          [(13) IBC, Section 308.5.2, is deleted.]
             247          [(14) In IBC, Section 310.1, in the subsection designated as R-1, at the end of the
             248      sentence beginning with "Congregate living facilities" the following is added: "or shall comply
             249      with the International Residential Code."]
             250          [(15) In IBC, Section 310.1, in the subsection designated as R-2, at the end of the
             251      sentence beginning with "Congregate living facilities" the following is added: "or shall comply
             252      with the International Residential Code."]
             253          [(16) In IBC, Section 310.1, the following is added at the end of the subsection
             254      designated as R-3: "Areas used for day care purposes may be located in a residential dwelling
             255      unit under all of the following conditions:]
             256      [1. Compliance with the Utah Administrative Code, R710-8, Day Care Rules, as enacted under
             257      the authority of the Utah Fire Prevention Board.]
             258      [2. Use is approved by the Utah Department of Health, as enacted under the authority of the
             259      Utah Code, Title 26, Chapter 39, Utah Child Care Licensing Act, and in any of the following
             260      categories:]
             261      [a. Utah Administrative Code, R430-50, Residential Certificate Child Care.]
             262      [b. Utah Administrative Code, R430-90, Licensed Family Child Care.]
             263      [3. Compliance with all zoning regulations of the local regulator."]
             264          [(17) In IBC, Section 310.1, the subsection designated as R-4 is deleted and replaced
             265      with the following: "R-4: Residential occupancies shall include buildings arranged for
             266      occupancy as Type I Assisted Living Facilities or Residential Treatment/Support Assisted
             267      Living Facilities including more than five but not more than 16 residents, excluding staff.]
             268      [Group R-4 occupancies shall meet the requirements for construction as defined for Group R-3
             269      except as otherwise provided for in this code."]
             270          [(18) In IBC, Section 310.2, the definition for "Residential Care/Assisted Living
             271      Facilities" is deleted and replaced with the following: "Assisted Living Facilities, see Section
             272      308.1.1".]
             273          (18) In IBC, Section 308.4, the following changes are made:
             274          (a) The words "five persons" are deleted and replaced with the words "three persons."
             275          (b) The words "foster care facilities" are deleted and replaced with "child care


             276      facilities."
             277          (c) The words "(both intermediate care facilities and skilled nursing facilities)" are
             278      added after "nursing homes."
             279          (d) The words "Ambulatory Surgical Centers with five or more operating rooms" are
             280      added to the list.
             281          (19) In IBC, Section 308.4.1, the word "five" is deleted and replaced with the word
             282      "three" in both places.
             283          (20) In IBC, Section 308.6, the word "five" is deleted and replaced with the word
             284      "four".
             285          (21) In IBC, Section 308.6.1, the following changes are made:
             286          (a) The word "five" is deleted and replaced with the word "four".
             287          (b) The words "2 ½ years or less of age" are deleted and replaced with "under the age
             288      of two".
             289          (c) The following sentence is added at the end: "See Section 425 for special
             290      requirements for Day Care."
             291          (22) In IBC, Sections 308.6.3 and 308.6.4, the word "five" is deleted and replaced with
             292      the word "four" in both places and the following sentence is added at the end: "See Section 425
             293      for special requirements for Day Care."
             294          (23) In IBC, Section 310.5, the words "and single family dwellings complying with the
             295      IRC" are added after "Residential occupancies".
             296          (24) In IBC, Section 310.5.1, the words "other than Child Care" are inserted after the
             297      word "dwelling" in the first sentence and the following sentence is added at the end: "See
             298      Section 425 for special requirements for Child Day Care."
             299          (25) A new IBC Section 310.5.2 is added as follows: "310.5.2 Child Care. Areas used
             300      for child care purposes may be located in a residential dwelling unit under all of the following
             301      conditions and Section 425:
             302      1. Compliance with Utah Administrative Code, R710-8, Day Care Rules, as enacted under the
             303      authority of the Utah Fire Prevention Board.
             304      2. Use is approved by the Utah Department of Health, as enacted under the authority of the
             305      Utah Code, Title 26. Chapter 39, Utah Child Care Licensing Act, and in any of the following
             306      categories:


             307      a. Utah Administrative Code, R430-50, Residential Certificate Child Care.
             308      b. Utah Administrative Code, R430-90, Licensed Family Child Care.
             309      3. Compliance with all zoning regulations of the local regulator."
             310          (26) In IBC, Section 310.6, the words "(see Section 308.2.1)" are added after "assisted
             311      living facilities".
             312          Section 4. Section 15A-3-103 is amended to read:
             313           15A-3-103. Amendments to Chapters 4 through 6 of IBC.
             314          (1) [Section] IBC[,] Section 403.5.5[,] is deleted.
             315          [(2) In IBC, Section 422.1, the words "Sections 422.1 to 422.6" are replaced with
             316      "Sections 422.1 to 422.7".]
             317          [(3) In IBC, Section 422, a new section is added as follows: "422.7 Separation.
             318      Occupancies classified as Group B Ambulatory Health Care Facilities shall be separated from
             319      all surrounding tenants and occupancies in accordance with Table 508.4 but not less than
             320      one-hour fire barrier when the suite is capable of providing care for four or more care recipients
             321      who are incapable of self preservation."]
             322          [(4) A new IBC, Section 424, is added as follows: "Section 424 Group E Child Day
             323      Care Centers. Group E child day care centers shall comply with Section 424.]
             324      [424.1 Location at grade. Group E child day care centers shall be located at the level of exit
             325      discharge.]
             326      [Exception: Child day care spaces for children over the age of 24 months may be located on the
             327      second floor of buildings equipped with automatic fire protection throughout and an automatic
             328      fire alarm system.]
             329      [424.2 Egress. All Group E child day care spaces with an occupant load of more than 10 shall
             330      have a second means of egress. If the second means of egress is not an exit door leading
             331      directly to the exterior, the room shall have an emergency escape and rescue window
             332      complying with Section 1029.]
             333      [424.3 All Group E Child Day Care Centers shall comply with Utah Administrative Code,
             334      R430-100, Child Care Centers."]
             335          (2) IBC Section (F)406.5.8 is deleted and replaced with the following: "(F)406.5.8
             336      Standpipe system. An open parking garage shall be equipped with an approved Class I manual
             337      standpipe system when fire department access is not provided for firefighting operations to


             338      within 150 feet of all portions of the open parking garage as measured from the approved fire
             339      department vehicle access.
             340      Exception: Open parking garages equipped throughout with an automatic sprinkler system in
             341      accordance with Section 903.3.1.1 and a standpipe system is not required by Section 905.3.1."
             342          (3) A new IBC Section (F)406.5.8.1 is added as follows: "(F) 406.5.8.1 Installation
             343      requirements. Class I manual standpipe shall be designed and installed in accordance with
             344      Section 905 and NFPA 14. Class I manual standpipe shall be accessible throughout the
             345      parking garage such that all portions of the parking structure are protected within 150 feet of a
             346      hose connection."
             347          (4) In IBC, Section 422.2, a new paragraph is added as follows: "422.2 Separations:
             348      Ambulatory care facilities licensed by the Utah Department of Health shall be separated from
             349      adjacent tenants with a fire barrier having a minimum one hour fire-resistance rating. Any
             350      level below the level of exit discharge shall be separated from the level of exit discharge by a
             351      horizontal assembly having a minimum one hour fire-resistance rating.
             352      Exception: A fire barrier is not required to separate the level of exit discharge when:
             353      1. Such levels are under the control of the Ambulatory Care Facility.
             354      2. Any hazardous spaces are separated by horizontal assembly having a minimum one hour
             355      fire-resistance rating."
             356          (5) A new IBC Section 425, Day Care, is added as follows:
             357      "425.1 Detailed Requirements. In addition to the occupancy and construction requirements in
             358      this code, the additional provisions of this section shall apply to all Day Care in accordance
             359      with Utah Administrative Code R710-8 Day Care Rules.
             360      425.2 Definitions.
             361      425.2.1 Authority Having Jurisdiction (AHJ): State Fire Marshal, his duly authorized deputies,
             362      or the local fire enforcement authority code official.
             363      425.2.2 Day Care Facility: Any building or structure occupied by clients of any age who
             364      receive custodial care for less than 24 hours by individuals other than parents, guardians,
             365      relatives by blood, marriage or adoption.
             366      425.2.3 Day Care Center: Providing care for five or more clients in a place other than the home
             367      of the person cared for. This would also include Child Care Centers, Out of School Time or
             368      Hourly Child Care Centers licensed by the Department of Health.


             369      425.2.4 Family Day Care: Providing care for clients listed in the following two groups:
             370      425.2.4.1 Type 1: Services provided for five to eight clients in a home. This would also
             371      include a home that is certified by the Department of Health as Residential Certificate Child
             372      Care or licensed as Family Child Care.
             373      425.2.4.2 Type 2: Services provided for nine to sixteen clients in a home with sufficient
             374      staffing. This would also include a home that is licensed by the Department of Health as
             375      Family Child Care.
             376      425.2.5 R710-8: Utah Administrative Code, R710-8, Day Care Rules, as enacted under the
             377      authority of the Utah Fire Prevention Board.
             378      425.3. Family Day Care.
             379      425.3.1 Family Day Care units shall have on each floor occupied by clients, two separate
             380      means of egress, arranged so that if one is blocked the other will be available.
             381      425.3.2 Family Day Care units that are located in the basement or on the second story shall be
             382      provided with two means of egress, one of which shall discharge directly to the outside.
             383      425.3.2.1 Residential Certificate Child Care and Licensed Family Child Care with five to eight
             384      clients in a home, located on the ground level or in a basement, may use an emergency escape
             385      or rescue window as allowed in IFC, Chapter 10, Section 1029.
             386      425.3.3 Family Day Care units shall not be located above the second story.
             387      425.3.4 In Family Day Care units, clients under the age of two shall not be located above or
             388      below the first story.
             389      425.3.4.1 Clients under the age of two may be housed above or below the first story where
             390      there is at least one exit that leads directly to the outside and complies with IFC, Section 1009
             391      or Section 1010 or Section 1026.
             392      425.3.5 Family Day Care units located in split entry/split level type homes in which stairs to
             393      the lower level and upper level are equal or nearly equal, may have clients housed on both
             394      levels when approved by the AHJ.
             395      425.3.6 Family Day Care units shall have a portable fire extinguisher on each level occupied by
             396      clients, which shall have a classification of not less than 2A:10BC, and shall be serviced in
             397      accordance with NFPA, Standard 10, Standard for Portable Fire Extinguishers.
             398      425.3.7 Family Day Care units shall have single station smoke detectors in good operating
             399      condition on each level occupied by clients. Battery operated smoke detectors shall be


             400      permitted if the facility demonstrates testing, maintenance, and battery replacement to insure
             401      continued operation of the smoke detectors.
             402      425.3.8 Rooms in Family Day Care units that are provided for clients to sleep or nap, shall
             403      have at least one window or door approved for emergency escape.
             404      425.3.9 Fire drills shall be conducted in Family Day Care units quarterly and shall include the
             405      complete evacuation from the building of all clients and staff. At least annually, in Type I
             406      Family Day Care units, the fire drill shall include the actual evacuation using the escape or
             407      rescue window, if one is used as a substitute for one of the required means of egress.
             408      425.4 Day Care Centers.
             409      425.4.1 Day Care Centers shall comply with either I-4 requirements or E requirements of the
             410      IBC, whichever is applicable for the type of Day Care Center.
             411      425.4.2 Emergency Evacuation Drills shall be completed as required in IFC, Chapter 4, Section
             412      405.
             413      425.4.3 Location at grade. Group E child day care centers shall be located at the level of exit
             414      discharge.
             415      425.4.3.1 Child day care spaces for children over the age of 24 months may be located on the
             416      second floor of buildings equipped with automatic fire protection throughout and an automatic
             417      fire alarm system.
             418      425.4.4 Egress. All Group E child day care spaces with an occupant load of more than 10 shall
             419      have a second means of egress. If the second means of egress is not an exit door leading
             420      directly to the exterior, the room shall have an emergency escape and rescue window
             421      complying with Section 1029.
             422      425.4.5 All Group E Child Day Care Centers shall comply with Utah Administrative Code,
             423      R430-100 Child Care Centers, R430-60 Hourly Child Care Centers, and R430-70 Out of
             424      School Time.
             425      425.5 Requirements for all Day Care
             426      425.5.1 Heating equipment in spaces occupied by children shall be provided with partitions,
             427      screens, or other means to protect children from hot surfaces and open flames.
             428      425.5.2 A fire escape plan shall be completed and posted in a conspicuous place. All staff shall
             429      be trained on the fire escape plan and procedure."
             430          [(5)] (6) In IBC, Section 504.2, a new section is added as follows: "504.2.1


             431      Notwithstanding the exceptions to Section 504.2, Group I-2 Assisted Living Facilities shall be
             432      allowed to be two stories of Type V-A construction when all of the following apply:
             433      1. All secured units are located at the level of exit discharge in compliance with Section
             434      1008.1.9.3 as amended;
             435      2. The total combined area of both stories shall not exceed the total allowable area for a
             436      one-story building; and
             437      3. All other provisions that apply in Section 407 have been provided."
             438          [(6) In IBC, Table 508.4, a new footnote g is added as follows: "g. See Section 422.7
             439      for additional requirements of Group B Ambulatory Health Care Facilities."]
             440          Section 5. Section 15A-3-104 is amended to read:
             441           15A-3-104. Amendments to Chapters 7 through 9 of IBC.
             442          [(1) In IBC, Section 707.5.1, a new exception 4 is added as follows: "4. Group B
             443      Ambulatory Health Care Facilities."]
             444          [(2) In IBC, Section (F)902, the definition for record drawings is deleted and replaced
             445      with the following: "(F) RECORD DRAWINGS. Drawings ("as builts") that document all
             446      aspects of a fire protection system as installed."]
             447          (1) IBC, Section (F)901.8, is deleted and replaced with the following: "(F)901.8 Pump
             448      and riser room size. Fire pump and automatic sprinkler system riser rooms shall be designed
             449      with adequate space for all installed equipment necessary for the installation and to provide
             450      sufficient working space around the stationary equipment. Clearances around equipment shall
             451      be in accordance with manufacturer requirements and not less than the following minimum
             452      elements:
             453      901.8.1 A minimum clear and unobstructed distance of 12-inches shall be provided from the
             454      installed equipment to the elements of permanent construction.
             455      901.8.2 A minimum clear and unobstructed distance of 12-inches shall be provided between
             456      all other installed equipment and appliances.
             457      901.8.3 A clear and unobstructed width of 36-inches shall be provided in front of all installed
             458      equipment and appliances, to allow for inspection, service, repair or replacement without
             459      removing such elements of permanent construction or disabling the function of a required
             460      fire-resistance-rated assembly.
             461      901.8.4 Automatic sprinkler system riser rooms shall be provided with a clear and


             462      unobstructed passageway to the riser room of not less than 36-inches, and openings into the
             463      room shall be clear and unobstructed, with doors swinging in the outward direction from the
             464      room and the opening providing a clear width of not less than 34-inches and a clear height of
             465      the door opening shall not be less than 80 inches.
             466      901.8.5 Fire pump rooms shall be provided with a clear and unobstructed passageway to the
             467      fire pump room of not less than 72-inches, and openings into the room shall be clear,
             468      unobstructed and large enough to allow for the removal of the largest piece of equipment, with
             469      doors swinging in the outward direction from the room and the opening providing a clear width
             470      of not less than 68-inches and a clear height of the door opening shall not be less than 80
             471      inches."
             472          [(3)] (2) In IBC, Section (F)903.2.2, the words ["all fire areas"] "the entire floor" are
             473      deleted and replaced with ["buildings"] "a building" and the last paragraph is deleted.
             474          [(4)] (3) IBC, Section (F)903.2.4, condition 2, is deleted and replaced with the
             475      following: "2. A Group F-1 fire area is located more than three stories above the lowest level
             476      of fire department vehicle access."
             477          [(5)] (4) IBC, Section (F)903.2.7, condition 2, is deleted and replaced with the
             478      following: "2. A Group M fire area is located more than three stories above the lowest level of
             479      fire department vehicle access."
             480          [(6)] (5) IBC, [Section] Sections (F)903.2.8, [is] (F)903.2.8.1, and (F)903.2.8.2, are
             481      deleted and replaced with the following: "(F)903.2.8 Group R. An automatic sprinkler system
             482      installed in accordance with Section 903.3 shall be provided throughout all buildings with a
             483      Group R fire area.
             484      Exceptions:
             485      1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses)
             486      constructed in accordance with the International Residential Code For One- and Two-Family
             487      Dwellings.
             488      2. Group R-4 fire areas not more than 4,500 gross square feet and not containing more than 16
             489      residents, provided the building is equipped throughout with an approved fire alarm system that
             490      is interconnected and receives its primary power from the building wiring and a commercial
             491      power system."
             492          [(7)] (6) IBC, Section (F)903.2.9, condition 2, is deleted and replaced with the


             493      following: "2. A Group S-1 fire area is located more than three stories above the lowest level
             494      of fire department vehicle access."
             495          [(8) IBC, Section (F)903.2.10, is deleted and replaced with the following: "(F)903.2.10
             496      Group S-2. An automatic sprinkler system shall be provided throughout buildings classified as
             497      parking garages in accordance with Section 406.2 or where located beneath other groups.]
             498      [Exception 1: Parking garages of less than 5,000 square feet (464 m2) accessory to Group R-3
             499      occupancies.]
             500      [Exception 2: Open parking garages not located beneath other groups if one of the following
             501      conditions is met:]
             502      [a. Access is provided for fire fighting operations to within 150 feet (45,720 mm) of all
             503      portions of the parking garage as measured from the approved fire department vehicle access;
             504      or]
             505      [b. Class I standpipes are installed throughout the parking garage."]
             506          [(9) In IBC, Section (F)903.2.10.1, the last clause "where the fire area exceeds 5,000
             507      square feet (464 m2)" is deleted.]
             508          [(10)] (7) IBC, Section (F)904.11, is deleted and replaced with the following:
             509      "(F)904.11 Commercial cooking systems. The automatic fire-extinguishing system for
             510      commercial cooking systems shall be of a type recognized for protection of commercial
             511      cooking equipment and exhaust systems. Pre-engineered automatic extinguishing systems
             512      shall be tested in accordance with UL 300 and listed and labeled for the intended application.
             513      The system shall be installed in accordance with this code, its listing and the manufacturer's
             514      installation instructions.
             515      Exception: Factory-built commercial cooking recirculating systems that are tested in
             516      accordance with UL 710B and listed, labeled, and installed in accordance with Section 304.1 of
             517      the International Mechanical Code."
             518          [(11)] (8) IBC, [Subsections] Sections (F)904.11.3, (F)904.11.3.1, (F)904.11.4, and
             519      (F)904.11.4.1, are deleted.
             520          [(12) A new IBC, Section (F)907.9, is added as follows: "Section (F)907.9 Carbon
             521      monoxide alarms. Carbon monoxide alarms shall be installed on each habitable level of a
             522      dwelling unit or sleeping unit in Groups R-2, R-3, R-4, and I-1 equipped with fuel burning
             523      appliances and in dwelling units that have attached garages. If more than one carbon monoxide


             524      alarm is required, they shall be interconnected as required in the International Fire Code,
             525      Chapter 9, Section 907.2.11.3. In new construction, carbon monoxide alarms shall receive
             526      their primary power as required in the International Fire Code, Chapter 9, Section 907.2.11.4.
             527      Listed single- and multiple-station carbon monoxide alarms shall comply with UL 2034 and
             528      shall be installed in accordance with the provisions of this code and NFPA 720."]
             529          (9) In IBC, Section (F)908.7, the exceptions are deleted and the following sentence is
             530      added after the first sentence: "A minimum of one carbon monoxide alarm shall be installed on
             531      each habitable level."
             532          (10) In IBC, Section (F)908.7, the following new subsections are added:
             533      "(F)908.7.1 Interconnection. Where more than one carbon monoxide alarm is required to be
             534      installed within Group R or I-1 occupancies, the carbon monoxide alarms shall be
             535      interconnected in such a manner that the activation of one alarm will activate all of the alarms.
             536      Physical interconnection of carbon monoxide alarms shall not be required where listed wireless
             537      alarms are installed and all alarms sound upon activation of one alarm. The alarm shall be
             538      clearly audible in all bedrooms over background noise levels with all intervening doors closed.
             539      (F)908.7.2 Power source. In new construction, required carbon monoxide alarms shall receive
             540      their primary power from the building wiring where such wiring is served from a commercial
             541      source and shall be equipped with a battery backup. Carbon monoxide alarms with integral
             542      strobes that are not equipped with battery backup shall be connected to an emergency electrical
             543      system. Carbon monoxide alarms shall emit a signal when the batteries are low. Wiring shall
             544      be permanent and without a disconnecting switch other than as required for overcurrent
             545      protection.
             546      Exception: Carbon monoxide alarms are not required to be equipped with battery backup where
             547      they are connected to an emergency electrical system."
             548          (11) IBC, Section (F)908.7.1, is renumbered to 908.7.3.
             549          Section 6. Section 15A-3-105 is amended to read:
             550           15A-3-105. Amendments to Chapters 10 through 12 of IBC.
             551          (1) In IBC, Section 1008.1.9.6[: (a)], the words "Group I-1 and" are added in the title
             552      and in the first sentence before the words "Group I-2"[;] and a new number 8 is added as
             553      follows: "8. The secure area or unit with special egress locks shall be located at the level of
             554      exit discharge in Type V construction."


             555          [(b) the word "delayed" is deleted throughout and replaced with "controlled"; and]
             556          [(c) the last sentence before the numbered subsections 1 through 6 is deleted.]
             557          (2) In IBC, Section 1008.1.9.7, a new number 7 is added as follows: "7. The secure
             558      area or unit with delayed egress locks shall be located at the level of exit discharge in Type V
             559      construction."
             560          [(2)] (3) In IBC, Section [1009.4.2] 1009.7.2, exception 5 is deleted and replaced with
             561      the following: "5. In Group R-3 occupancies, within dwelling units in Group R-2 occupancies,
             562      and in Group U occupancies that are accessory to a Group R-3 occupancy, or accessory to
             563      individual dwelling units in Group R-2 occupancies, the maximum riser height shall be 8
             564      inches (203 mm) and the minimum tread depth shall be 9 inches (229 mm). The minimum
             565      winder tread depth at the walk line shall be 10 inches (254 mm), and the minimum winder
             566      tread depth shall be 6 inches (152 mm). A nosing not less than 0.75 inch (19.1 mm) but not
             567      more than 1.25 inches (32 mm) shall be provided on stairways with solid risers where the tread
             568      depth is less than 10 inches (254 mm)."
             569          [(3)] (4) In IBC, Section [1009.12] 1009.15, a new exception 6 is added as follows: "6.
             570      In occupancies in Group R-3, as applicable in Section 101.2 and in occupancies in Group U,
             571      which are accessory to an occupancy in Group R-3, as applicable in Section 101.2, handrails
             572      shall be provided on at least one side of stairways consisting of four or more risers."
             573          [(4) In IBC, Section 1013.2, the words "adjacent fixed seating" are deleted.]
             574          [(5) In IBC, Section 1013.2, a new exception 5 is added as follows: "5. For
             575      occupancies in Group R-3 and within individual dwelling units in occupancies in Group R-2,
             576      as applicable in Section 101.2, guards shall form a protective barrier not less than 36 inches
             577      (914 mm) in height."]
             578          [(6) In IBC, Section 1015.2.2, the following sentence is added at the end: "Additional
             579      exits or exit access doorways shall be arranged a reasonable distance apart so that if one
             580      becomes blocked, the others will be available."]
             581          (5) In IBC, Section 1011.5, the words ", including when the building may not be fully
             582      occupied." are added at the end of the sentence.
             583          [(7)] (6) IBC, Section 1024, is deleted.
             584          [(8) A new IBC, Section 1109.7.1, is added as follows: "1109.7.1 Platform
             585      (wheelchair) lifts. All platform (wheelchair) lifts shall be capable of independent operation


             586      without a key."]
             587          (7) In IBC, Section 1028.12, exception 2 is deleted.
             588          (8) In IBC, Section 1109.8, the following words "shall be capable of operation without
             589      a key and" are inserted in the second sentence between the words "lift" and "shall".
             590          (9) In IBC, Section 1208.4, subparagraph 1 is deleted and replaced with the following:
             591      "1. The unit shall have a living room of not less than 165 square feet (15.3 m2) of floor area.
             592      An additional 100 square feet (9.3 m2) of floor area shall be provided for each occupant of such
             593      unit in excess of two."
             594          Section 7. Section 15A-3-107 is amended to read:
             595           15A-3-107. Amendments to Chapter 16 of IBC.
             596          (1) In IBC, Table 1604.5, [Occupancy] Risk Category III, in the sentence that begins
             597      "Group I-2," a new footnote [b] c is added as follows: ["b] "c. Type II Assisted Living
             598      Facilities that are I-2 occupancy classifications in accordance with Section 308 shall be
             599      [Occupancy] Risk Category II in this table."
             600          (2) In IBC, Section [1605.2.1, the formula shown as "f2 = 0.2 for other roof
             601      configurations" is] 1605.2, in the portion of the definition for the value of f2, the words "and
             602      0.2 for other roof configurations" are deleted and replaced with the following: "f2 = 0.20 +
             603      .025(A-5) for other configurations where roof snow load exceeds 30 psf;
             604      f2 = 0 for roof snow loads of 30 psf (1.44kN/m2) or less.
             605      Where A = Elevation above sea level at the location of the structure (ft./1,000)."
             606          (3) In IBC, [Section] Sections 1605.3.1 and [Section] 1605.3.2, exception 2 in each
             607      section is deleted and replaced with the following: "2. Flat roof snow loads of 30 pounds per
             608      square foot (1.44 kNm2) or less need not be combined with seismic loads. Where flat roof
             609      snow loads exceed 30 pounds per square foot (1.44 kNm2), the snow loads may be reduced in
             610      accordance with the following in load combinations including both snow and seismic loads.
             611      Ws as calculated below, shall be combined with seismic loads.
             612      Ws = (0.20 + 0.025(A-5))Pf is greater than or equal to 0.20 Pf.
             613      Where:
             614      Ws = Weight of snow to be included in seismic calculations
             615      A = Elevation above sea level at the location of the structure (ft./1,000)
             616      Pf = Design roof snow load, psf.


             617      For the purpose of this section, snow load shall be assumed uniform on the roof footprint
             618      without including the effects of drift or sliding. The Importance Factor, I, used in calculating Pf
             619      may be considered 1.0 for use in the formula for Ws".
             620          (4) IBC, Section 1608.1, is deleted and replaced with the following: "1608.1 General.
             621      Except as modified in Sections 1608.1.1, 1608.1.2, and 1608.1.3, design snow loads shall be
             622      determined in accordance with Chapter 7 of ASCE 7, but the design roof load shall not be less
             623      than that determined by Section 1607."
             624          (5) A new IBC, Section 1608.1.1, is added as follows: "1608.1.1 Section 7.4.5 of
             625      Chapter 7 of ASCE 7 referenced in Section 1608.1 of the IBC is deleted and replaced with the
             626      following: ["]Section 7.4.5 Ice Dams and Icicles Along Eaves. Where ground snow loads
             627      exceed 75 psf, eaves shall be capable of sustaining a uniformly distributed load of 2pf on all
             628      overhanging portions. No other loads except dead loads shall be present on the roof when this
             629      uniformly distributed load is applied. All building exits under down-slope eaves shall be
             630      protected from sliding snow and ice."
             631          (6) In IBC, Section 1608.1.2, a new section is added as follows: "1608.1.2 Utah Snow
             632      Loads. The snow loads specified in Table 1608.1.2(b) shall be used for the jurisdictions
             633      identified in that table. Otherwise, the ground snow load, Pg, to be used in the determination of
             634      design snow loads for buildings and other structures shall be determined by using the following
             635      formula: Pg = (Po2 + S2(A-Ao)2)0.5 for A greater than Ao, and Pg = Po for A less than or equal to
             636      Ao.
             637      WHERE:
             638      Pg = Ground snow load at a given elevation (psf);
             639      Po = Base ground snow load (psf) from Table No. 1608.1.2(a);
             640      S = Change in ground snow load with elevation (psf/100 ft.) From Table No. 1608.1.2(a);
             641      A = Elevation above sea level at the site (ft./1,000);
             642      Ao = Base ground snow elevation from Table 1608.1.2(a) (ft./1,000).
             643      The building official may round the roof snow load to the nearest 5 psf. The ground snow
             644      load, Pg, may be adjusted by the building official when a licensed engineer or architect submits
             645      data substantiating the adjustments. [A record of such action together with the substantiating
             646      data shall be provided to the division for a permanent record.]
             647      [The building official may also directly adopt roof snow loads in accordance with Table


             648      1608.1.2(b), provided the site is no more than 100 ft. higher than the listed elevation.]
             649      Where the minimum roof live load in accordance with Section 1607.11 is greater than the
             650      design roof snow load, such roof live load shall be used for design, however, it shall not be
             651      reduced to a load lower than the design roof snow load. Drifting need not be considered for
             652      roof snow loads less than 20 psf."
             653          (7) IBC, Table 1608.1.2(a) and Table 1608.1.2(b), are added as follows:
             654     
"TABLE NO. 1608.1.2(a)
             655     
STATE OF UTAH - REGIONAL SNOW LOAD FACTORS
             656      COUNTY Po S Ao
             657      Beaver 43 63 6.2
             658      Box Elder 43 63 5.2
             659      Cache 50 63 4.5
             660      Carbon 43 63 5.2
             661      Daggett 43 63 6.5
             662      Davis 43 63 4.5
             663      Duchesne 43 63 6.5
             664      Emery 43 63 6.0
             665      Garfield 43 63 6.0
             666      Grand 36 63 6.5
             667      Iron 43 63 5.8
             668      Juab 43 63 5.2
             669      Kane 36 63 5.7
             670      Millard 43 63 5.3
             671      Morgan 57 63 4.5
             672      Piute 43 63 6.2
             673      Rich 57 63 4.1
             674      Salt Lake 43 63 4.5
             675      San Juan 43 63 6.5
             676      Sanpete 43 63 5.2
             677      Sevier 43 63 6.0
             678      Summit 86 63 5.0
             679      Tooele 43 63 4.5
             680      Uintah 43 63 7.0
             681      Utah 43 63 4.5
             682      Wasatch 86 63 5.0
             683      Washington 29 63 6.0
             684      Wayne 36 63 6.5
             685      Weber 43 63 4.5
             686     
[TABLE NO. 1608.1.2(b)]
             687     
[RECOMMENDED SNOW LOADS FOR SELECTED UTAH CITIES AND TOWNS(2)]
             688      [Roof Snow
Load (PSF)
]
[Ground Snow
Load (PSF)
]
             689      [Beaver County]
             690          [Beaver] [5,920 ft.] [43] [62]
             691      [Box Elder County]
             692          [Brigham City] [4,300 ft.] [30] [43]
             693          [Tremonton] [4,290 ft.] [30] [43]
             694      [Cache County]
             695          [Logan] [4,530 ft.] [35] [50]
             696          [Smithfield] [4,595 ft.] [35] [50]
             697      [Carbon County]
             698          [Price] [5,550 ft.] [30] [43]
             699      [Daggett County]
             700          [Manila] [5,377 ft.] [30] [43]
             701      [Davis County]
             702          [Bountiful] [4,300 ft.] [30] [43]
             703          [Farmington] [4,270 ft.] [30] [43]
             704          [Layton] [4,400 ft.] [30 ] [43]
             705          [Fruit Heights] [4,500 ft.] [40] [57]
             706      [Duchesne County]
             707          [Duchesne] [5,510 ft.] [30] [43]
             708          [Roosevelt] [5,104 ft.] [30] [43]
             709      [Emery County]
             710          [Castledale] [5,660 ft.] [30] [43]
             711          [Green River] [4,070 ft.] [25] [36]
             712      [Garfield County]
             713          [Panguitch] [6,600 ft.] [30] [43]
             714      [Grand County]
             715          [Moab] [3,965 ft.] [25] [36]
             716      [Iron County]
             717          [Cedar City] [5,831 ft.] [30] [43]
             718      [Juab County]
             719          [Nephi] [5,130 ft.] [30] [43]
             720      [Kane County]
             721          [Kanab] [5,000 ft.] [25] [36]
             722      [Millard County]
             723          [Millard] [5,000 ft.] [30] [43]
             724          [Delta] [4,623 ft.] [30] [43]
             725      [Morgan County]
             726          [Morgan] [5,064 ft.] [40] [57]
             727      [Piute County]
             728          [Piute] [5,996 ft.] [30] [43]
             729      [Rich County]
             730          [Woodruff] [6,315 ft.] [40] [57]
             731      [Salt Lake County]
             732          [Murray] [4,325 ft.] [30] [43]
             733          [Salt Lake City] [4,300 ft.] [30] [43]
             734          [Sandy] [4,500 ft.] [30] [43]
             735          [West Jordan] [4,375 ft.] [30] [43]
             736          [West Valley] [4,250 ft.] [30] [43]
             737      [San Juan County]
             738          [Blanding] [6,200 ft.] [30] [43]
             739          [Monticello] [6,820 ft.] [35] [50]
             740      [Sanpete County]
             741          [Fairview] [6,750 ft.] [35] [50]
             742          [Mt. Pleasant] [5,900 ft.] [30] [43]
             743          [Manti] [5,740 ft.] [30] [43]
             744          [Ephraim] [5,540 ft.] [30] [43]
             745          [Gunnison] [5,145 ft.] [30] [43]
             746      [Sevier County]
             747          [Salina] [5,130 ft.] [30] [43]
             748          [Richfield] [5,270 ft.] [30] [43]
             749      [Summit County]
             750          [Coalville] [5,600 ft.] [60] [86]
             751          [Kamas] [6,500 ft.] [70] [100]
             752          [Park City] [6,800 ft.] [100] [142]
             753          [Park City] [8,400 ft.] [162] [231]
             754          [Summit Park] [7,200 ft.] [90] [128]
             755      [Tooele County]
             756          [Tooele] [5,100 ft.] [30] [43]
             757      [Uintah County]
             758          [Vernal] [5,280 ft.] [30] [43]
             759      [Utah County]
             760          [American Fork] [4,500 ft.] [30] [43]
             761          [Orem] [4,650 ft.] [30] [43]
             762          [Pleasant Grove] [5,000 ft.] [30] [43]
             763          [Provo] [5,000 ft.] [30] [43]
             764          [Spanish Fork] [4,720 ft.] [30] [43]
             765      [Wasatch County]
             766          [Heber] [5,630 ft.] [60] [86]
             767      [Washington County]
             768          [Central] [5,209 ft.] [25] [36]
             769          [Dameron] [4,550 ft.] [25] [36]
             770          [Leeds] [3,460 ft.] [20] [29]
             771          [Rockville] [3,700 ft.] [25] [36]
             772          [Santa Clara] [2,850 ft.] [15 (1)] [21]
             773          [St. George] [2,750 ft.] [15 (1)] [21]
             774      [Wayne County]
             775          [Loa] [7,080 ft.] [30] [43]
             776          [Hanksville] [4,308 ft.] [25] [36]
             777      [Weber County]
             778          [North Ogden] [4,500 ft.] [40] [57]
             779          [Ogden] [4,350 ft.] [30] [43]
             780      [NOTES]
             781      [(1) The IBC requires a minimum live load - See 1607.11.2.]
             782      [(2) This table is informational only in that actual site elevations may vary. Table is only
valid if site elevation is within 100 feet of the listed elevation."
]
             783     
TABLE NO. 1608.1.2(B)
             784     
REQUIRED SNOW LOADS FOR SELECTED UTAH CITIES AND TOWNS1,2
             785      The following jurisdictions require design snow load values that differ from the Equation in
the Utah Snow Load Study.
             786      County City Elevation Ground Snow
Load (psf)
Roof Snow
Load (psf) 6
             787      Carbon Price3
All other county locations5
5550
--
43
--
30
--
             788      Davis Fruit Heights3 4500 - 4850 57 40
             789      Emery Green River3 4070 36 25
             790      Garfield Panguitch3 6600 43 30
             791      Rich Woodruff3
Laketown4
Garden City5
Randolph4
6315
6000
--
6300
57
57
--
57
40
40
--
40
             792      San Juan Monticello3 6820 50 35
             793      Summit Coalville3
Kamas4
5600
6500
86
114
60
80
             794      Tooele Tooele3 5100 43 30
             795      Utah Orem3
Pleasant Grove4
Provo5
4650
5000
--
43
43
--
30
30
--
             796      Wasatch Heber5 -- -- --
             797      Washington Leeds3
Santa Clara3
St. George3
All other county locations5
3460

2850

2750

--
29
21
21
--
20
15
15
--
             798      Wayne Loa3
7080
43 30
             799      1The IBC requires a minimum live load - See 1607.11.2.
             800      2This table is informational only in that actual site elevations may vary. Table is only valid if
site elevation is within 100 feet of the listed elevation. Otherwise, contact the local Building
Official.
             801      3Values adopted form Table VII of the Utah Snow Load Study.
             802      4Values based on site-specific study. Contact local Building Official for additional
information.
             803      5Contact local Building Official.
             804      6Based on Ce =1.0, Ct =1.0 and Is =1.0"
             805          (8) A new IBC, Section 1608.1.3, is added as follows: "1608.1.3 Thermal Factor. The
             806      value for the thermal factor, Ct, used in calculation of Pf shall be determined from Table 7.3 in
             807      ASCE 7.
             808      Exception: Except for unheated structures, the value of Ct need not exceed 1.0 when ground
             809      snow load, Pg is calculated using Section 1608.1.2 as amended."
             810          (9) IBC, Section 1608.2, is deleted and replaced with the following: "1608.2 Ground
             811      Snow Loads. The ground snow loads to be used in determining the design snow loads for roofs
             812      in states other than Utah are given in Figure 1608.2 for the contiguous United States and Table
             813      1608.2 for Alaska. Site-specific case studies shall be made in areas designated CS in figure
             814      1608.2. Ground snow loads for sites at elevations above the limits indicated in Figure 1608.2
             815      and for all sites within the CS areas shall be approved. Ground snow load determination for
             816      such sites shall be based on an extreme value statistical analysis of data available in the vicinity
             817      of the site using a value with a 2-percent annual probability of being exceeded (50-year mean
             818      recurrence interval). Snow loads are zero for Hawaii, except in mountainous regions as
             819      approved by the building official."
             820          [(10) In IBC, Section 1609.1.1, a new exception 7 is added as follows: "7. The wind
             821      design procedure as found in Sections 1616 through 1624 of the 1997 Uniform Building Code
             822      may be used as an alternative wind design procedure for signs and free standing walls as listed
             823      in item 7 listed in Table 16-H of the 1997 Uniform Building Code. The Importance Factor, I,
             824      shall be determined in accordance with Table 6-1 of ASCE 7. Stress increases are only
             825      allowed as provided in Section 1605.3 of the 2009 IBC."]
             826          [(11)] (10) A new IBC, Section 1613.1.1, is added as follows: "1613.1.1 ASCE 12.7.2
             827      and 12.14.8.1 of Chapter 12 of ASCE 7 referenced in Section 1613.1, Definition of W, Item 4
             828      is deleted and replaced with the following:
             829      4. Where the flat roof snow load, Pf, exceeds 30 psf, the snow load included in seismic design
             830      shall be calculated, in accordance with the following formula: Ws = (0.20 + 0.025(A-5))Pf is
             831      greater than or equal to 0.20 Pf.


             832      WHERE:
             833      Ws = Weight of snow to be included in seismic calculations
             834      A = Elevation above sea level at the location of the structure (ft./1,000)
             835      Pf = Design roof snow load, psf.
             836      For the purposes of this section, snow load shall be assumed uniform on the roof footprint
             837      without including the effects of drift or sliding. The Importance Factor, I, used in calculating Pf
             838      may be considered 1.0 for use in the formula for Ws."
             839          [(12)] (11) A new IBC, Section [1613.8] 1613.5, is added as follows: "[1613.8] 1613.5
             840      ASCE 7, Section 13.5.6.2.2 paragraph (e) is modified to read as follows: (e) Penetrations shall
             841      have a sleeve or adapter through the ceiling tile to allow for free movement of at least 1 inch
             842      (25 mm) in all horizontal directions.
             843      Exceptions:
             844      1. Where rigid braces are used to limit lateral deflections.
             845      2. At fire sprinkler heads in frangible surfaces per NFPA 13."
             846          Section 8. Section 15A-3-108 is amended to read:
             847           15A-3-108. Amendments to Chapters 17 through 19 of IBC.
             848          (1) A new IBC, Section 1807.1.6.4, is added as follows: "1807.1.6.4 Empirical
             849      concrete foundation design. Group R, Division 3 Occupancies three stories or less in height,
             850      and Group U Occupancies, which are constructed in accordance with Section 2308, or with
             851      other methods employing repetitive wood-frame construction or repetitive cold-formed steel
             852      structural member construction, shall be permitted to have concrete foundations constructed in
             853      accordance with Table 1807.1.6.4."
             854          (2) A new IBC, Table 1807.1.6.4 is added as follows:
             855     
"TABLE 1807.1.6.4
             856     
EMPIRICAL FOUNDATION WALLS (1,7,8)
             857      Max. Height Top Edge
Support
Min.
Thickness
Vertical
Steel (2)
Horizontal
Steel (3)
Steel at
Openings (4)
Max. Lintel
Length
Min. Lintel
Length
             858      2'(610 mm) None 6" (5) 2- #4 Bars 2- #4 Bars above
1- #4 Bar each side
1- #4 Bar below
2'(610 mm) 2" for each foot
of opening
width;
min. 6"
             859      3'(914 mm) None 6" #4@32" 3- #4 Bars 2- #4 Bars above
1- #4 Bar each side
1- #4 Bar below
2'(610 mm) 2" for each foot
of opening
width;
min. 6"
             860      4'(1,219 mm) None 6" #4@32" 4- #4 Bars 2- #4 Bars above
1- #4 Bar each side
1- #4 Bar below
3'(914 mm) 2" for each foot
of opening
width;
min. 6"
             861      6'(1,829 mm) Floor or roof
Diaphragm
(6)
8" #4@24" 5- #4 Bars 2- #4 Bars above
1- #4 Bar each side
1- #4 Bar below
6'(1,829 mm) 2" for each foot
of opening
width;
min. 6"
             862      8'(2,438 mm) Floor or roof
Diaphragm
(6)
8" #4@24" 6- #4 Bars 2- #4 Bars above
1- #4 Bar each side
1- #4 Bar below
6'(1,829 mm) 2" for each foot
of opening
width;
min. 6"
             863      9'(2,743 mm) Floor or roof
Diaphragm
(6)
8" #4@16" 7- #4 Bars 2- #4 Bars above
1- #4 Bar each side
1- #4 Bar below
6'(1,829 mm) 2" for each foot
of opening
width;
min. 6"
             864      Over 9'(2,743 mm), Engineering required for each column
             865      Footnotes:
             866      (1) Based on 3,000 psi (20.6 Mpa) concrete and 60,000 psi (414 Mpa) reinforcing steel.
             867      (2) To be placed in the center of the wall, and extended from the footing to within three
inches (76 mm) of the top of the wall; dowels of #4 bars to match vertical steel placement
shall be provided in the footing, extending 24 inches (610 mm) into the foundation wall.
             868      (3) One bar shall be located in the top four inches (102 mm), one bar in the bottom four
inches (102 mm) and the other bars equally spaced between. Such bar placement satisfies the
requirements of Section 1805.9. Corner reinforcing shall be provided so as to lap 24 inches
(610 mm).
             869      (4) Bars shall be placed within two inches (51 mm) of the openings and extend 24 inches
(610 mm) beyond the edge of the opening; vertical bars may terminate three inches (76 mm)
from the top of the concrete.
             870      (5) Dowels of #4 bar at 32 inches on center shall be provided in the footing, extending 18
inches (457 mm) into the foundation wall.
             871      (6) Diaphragm shall conform to the requirements of Section 2308.
             872      (7) Footing shall be a minimum of nine inches thick by 20 inches wide.
             873      (8) Soil backfill shall be soil classification types GW, GP, SW, or SP, per Table 1610.1. Soil
shall not be submerged or saturated in groundwater."
             874          (3) In IBC, Section [1904.3] 1904.2, a new exception 1 is added as follows and the
             875      current exception is modified to be number 2.
             876          Exceptions:
             877          "1. In ACI Table 4.3.1, for Exposure Class F1, change Maximum w/cm from 0.45 to
             878      0.5 and Minimum f'c from 4,500 psi to 3,000 psi."
             879          [(4) IBC, Section 1904.4.1 is deleted and replaced with the following:]
             880          ["1904.4.1 Air Entrainment. Concrete that extends above grade and is exposed to
             881      freezing and thawing while moist shall be air entrained in accordance with ACI 318, Section
             882      4.4.1."]
             883          (4) A new IBC, Section 1905.1.11, is added as follows: "1905.1.11 ACI 318, Table
             884      4.2.1." Modify ACI 318, Table 4.2.1 to read as follows: In the portion of the table designated
             885      as "Conditions", the Exposure categories and classes are deleted and replaced with the
             886      following:
             887      "F0: Concrete elements not exposed to freezing and thawing cycles to include footing and
             888      foundation elements that are completely buried in soil.
             889      F1: Concrete elements exposed to freezing and thawing cycles and are not likely to be saturated
             890      or exposed to deicing chemicals.
             891      F2: Concrete elements exposed to freezing and thawing cycles and are likely to be saturated,
             892      but not exposed to deicing chemicals.
             893      F3: Concrete elements exposed to freezing and thawing cycles and are likely to be saturated
             894      and exposed to deicing chemicals."
             895          Section 9. Section 15A-3-110 is amended to read:
             896           15A-3-110. Amendments to Chapters 23 through 25 of IBC.
             897          (1) A new IBC, Section 2306.1.5, is added as follows: "2306.1.5 Load duration factors.
             898      The allowable stress increase of 1.15 for snow load, shown in Table 2.3.2, Frequently Used
             899      Load Duration Factors, Cd, of the National Design Specifications, shall not be utilized at
             900      elevations above 5,000 feet (1,524 M)."
             901          (2) In IBC, Section 2308.6, a new exception is added as follows: "Exception: Where


             902      foundation plates or sills are bolted or anchored to the foundation with not less than 1/2 inch
             903      (12.7 mm) diameter steel bolts or approved anchors, embedded at least 7 inches (178 mm) into
             904      concrete or masonry and spaced not more than 32 inches (816 mm) apart, there shall be a
             905      minimum of two bolts or anchor straps per piece located not less than 4 inches (102 mm) from
             906      each end of each piece. A properly sized nut and washer shall be tightened on each bolt to the
             907      plate."
             908          (3) IBC, Section 2506.2.1, is deleted and replaced with the following: "2506.2.1 Other
             909      materials. Metal suspension systems for acoustical and lay-in panel ceilings shall conform with
             910      ASTM C635 listed in Chapter 35 and Section 13.5.6 of ASCE [7-05] 7, as amended in Section
             911      1613.8, for installation in high seismic areas."
             912          Section 10. Section 15A-3-112 is amended to read:
             913           15A-3-112. Amendments to Chapters 29 through 31 of IBC.
             914          (1) In IBC[, Section 2902.1, the title for] [P] Table 2902.1 [is deleted and replaced and
             915      a new footnote g is added as follows] the following changes are made:
             916          (a) ["]    The title for [P] Table 2902.1 is deleted and replaced with the following: "[P]
             917      Table 2902.1, Minimum Number of Required Plumbing Facilities a, [g] h"[; and].
             918          (b) In the row for "E" occupancy in the field for "OTHER" a new footnote i is added.
             919          (c) In the row for "I-4" occupancy in the field for "OTHER" a new footnote i is added.
             920          [(b)] (d) A new footnote h is added as follows: "FOOTNOTE: [g] h. When provided,
             921      in public toilet facilities there shall be an equal number of diaper changing facilities in male
             922      toilet rooms and female toilet rooms."
             923          (e) A new footnote i is added to the table as follows: "FOOTNOTE i: Non-residential
             924      child care facilities shall comply with additional sink requirements of Utah Administrative
             925      Code R430-100-4."
             926          (2) In IBC, Section 3006.5, a new exception is added as follows: "Exception: Hydraulic
             927      elevators and roped hydraulic elevators with a rise of 50 feet or less."
             928          Section 11. Section 15A-3-113 is amended to read:
             929           15A-3-113. Amendments to Chapters 32 through 35 of IBC.
             930          (1) A new section IBC, Section 3401.6, is added as follows: "3401.6 Parapet bracing,
             931      wall anchors, and other appendages. Until June 30, 2014, a building constructed before 1975
             932      shall have parapet bracing, wall anchors, and appendages such as cornices, spires, towers,


             933      tanks, signs, statuary, etc. evaluated by a licensed engineer when the building is undergoing
             934      structural alterations, which may include structural sheathing replacement of 10% or greater, or
             935      other structural repairs. Reroofing or water membrane replacement may not be considered a
             936      structural alteration or repair for purposes of this section. Beginning July 1, 2014, a building
             937      constructed before 1975 shall have parapet bracing, wall anchors, and appendages such as
             938      cornices, spires, towers, tanks, signs, statuary, etc. evaluated by a licensed engineer when the
             939      building is undergoing a total reroofing. Parapet bracing, wall anchors, and appendages
             940      required by this section shall be evaluated in accordance with 75% of the seismic forces as
             941      specified in Section 1613. When allowed by the local building official, alternate methods of
             942      equivalent strength as referenced in an approved code under Utah Code, Subsection
             943      15A-1-204 (6)(a), will be considered when accompanied by engineer-sealed drawings, details,
             944      and calculations. When found to be deficient because of design or deteriorated condition, the
             945      engineer's recommendations to anchor, brace, reinforce, or remove the deficient feature shall be
             946      implemented.
             947      Exceptions:
             948      1. Group R-3 and U occupancies.
             949      2. Unreinforced masonry parapets need not be braced according to the above stated provisions
             950      provided that the maximum height of an unreinforced masonry parapet above the level of the
             951      diaphragm tension anchors or above the parapet braces shall not exceed one and one-half times
             952      the thickness of the parapet wall. The parapet height may be a maximum of two and one-half
             953      times its thickness in other than Seismic Design Categories D, E, or F."
             954          (2) IBC, Section 3408.4, is deleted and replaced with the following: "3408.4 [Change
             955      in Occupancy] Seismic. When a change in occupancy results in a structure being reclassified
             956      to a higher [Occupancy] Risk Category (as defined in Table 1604.5), or when such change of
             957      occupancy results in a design occupant load increase of 100% or more, the structure shall
             958      conform to the seismic requirements for a new structure.
             959      Exceptions:
             960      1. Specific seismic detailing requirements of this code or ASCE 7 for a new structure shall not
             961      be required to be met where it can be shown that the level of performance and seismic safety is
             962      equivalent to that of a new structure. [Such] A demonstration of equivalence analysis shall
             963      consider the regularity, overstrength, redundancy, and ductility of the structure [within the


             964      context of the existing and retrofit (if any) detailing providing]. Alternatively, the building
             965      official may allow the structure to be upgraded in accordance with referenced sections as found
             966      in an approved code under Utah Code, Subsection 15A-1-204 (6)(a).
             967      2. When a change of use results in a structure being reclassified from [Occupancy] Risk
             968      Category I or II to [Occupancy] Risk Category III and the structure is located in a seismic map
             969      area where SDS is less than 0.33, compliance with the seismic requirements of this code and
             970      ASCE 7 are not required.
             971      3. Where design occupant load increase is less than 25 occupants and the [Occupancy] Risk
             972      Category does not change."
             973          [(3) In IBC, Section 3411.1, the exception is deleted and replaced with the following:
             974      "Exception: Type B dwelling or sleeping units required by Section 1107 of this code are not
             975      required to be provided in existing buildings and facilities unless being altered or undergoing a
             976      change of occupancy classification."]
             977          [(4) In IBC, Chapter 35, the referenced standard ACI 318-08 is modified to change
             978      Table 4.2.1 of ACI 318-08 as follows: In the portion of Table 4.2.1 designated as "Conditions",
             979      the Exposure categories and classes are deleted and replaced with the following:]
             980          ["F0: Concrete elements not exposed to freezing and thawing cycles to include footing
             981      and foundation elements that are completely buried in soil.]
             982          [F1: Concrete elements exposed to freezing and thawing cycles and are not likely to be
             983      saturated or exposed to deicing chemicals.]
             984          [F2: Concrete elements exposed to freezing and thawing cycles and are likely to be
             985      saturated, but not exposed to deicing chemicals.]
             986          [F3: Concrete elements exposed to freezing and thawing cycles and are likely to be
             987      saturated and exposed to deicing chemicals."]
             988          [(5)] (3) In IBC, Chapter 35, the referenced standard [ICC/ANSI A117.1-03]
             989      ICCA117.1-09, Section 606.2, Exception 1 is modified to include the following sentence at the
             990      end of the exception:
             991          "The minimum clear floor space shall be centered on the sink assembly."
             992          [(6) The following referenced standard is added under NFPA in IBC, Chapter 35:]
             993      ["Number] [Title] [Referenced in code section
number
]
             994      [720-09] [Standard for the Installation of
Carbon Monoxide (CO) Detection and
Warning Equipment
]
[907.9"]
             995          [(7)] (4) The following referenced standard is added under UL in IBC, Chapter 35:
             996      "Number Title Referenced in code section number
             997      2034-2008 Standard of Single- and
Multiple-station Carbon Monoxide
Alarms
907.9"
             998          [(8) In IBC, Chapter 35, NFPA referenced standard 10-07 is deleted and replaced with
             999      the following:]
             1000      ["Number] [Title] [Referenced in code section
number
]
             1001      [10-10] [Portable Fire Extinguishers] [906.2, 906.3.2, 906.3.4, Table
906.3(1), Table 906.3(2)"
]
             1002          [(9) In IBC, Chapter 35, NFPA referenced standard 11-05 is deleted and replaced with
             1003      the following:]
             1004      ["Number] [Title] [Referenced in code section
number
]
             1005      [11-10] [Low Expansion Foam] [904.7"]
             1006          [(10) In IBC, Chapter 35, NFPA referenced standard 12-05 is deleted and replaced with
             1007      the following:]
             1008      ["Number] [Title] [Referenced in code section
number
]
             1009      [12-08] [Carbon Dioxide Extinguishing
Systems
]
[904.8, 904.11"]
             1010          [(11) In IBC, Chapter 35, NFPA referenced standard 12A-04 is deleted and replaced
             1011      with the following:]


             1012      ["Number] [Title] [Referenced in code section
number
]
             1013      [12A-09] [Halon 1301 Fire Extinguishing
Systems
]
[904.9"]
             1014          [(12) In IBC, Chapter 35, NFPA referenced standard 13-07 is deleted and replaced with
             1015      the following:]
             1016      ["Number] [Title] [Referenced in code section
number
]
             1017      [13-10] [Installation of Sprinkler Systems] [708.2, 903.3.1.1, 903.3.2,
903.3.5.1.1, 903.3.5.3, 904.11,
905.3.4, 907.6.3, 1613.3"
]
             1018          [(13) In IBC, Chapter 35, NFPA referenced standard 13D-07 is deleted and replaced
             1019      with the following:]
             1020      ["Number] [Title] [Referenced in code section
number
]
             1021      [13D-10] [Installation of Sprinkler Systems in
One- and Two-family Dwellings and
Manufactured Homes
]
[903.3.1.3, 903.3.5.1.1"]
             1022          [(14) In IBC, Chapter 35, NFPA referenced standard 13R-07 is deleted and replaced
             1023      with the following:]
             1024      ["Number] [Title] [Referenced in code section
number
]
             1025      [13R-10] [Installation of Sprinkler Systems in
Residential Occupancies Up to and
Including Four Stories in Height
]
[903.3.1.2, 903.3.5.1.1, 903.3.5.1.2,
903.4"
]
             1026          [(15) In IBC, Chapter 35, NFPA referenced standard 14-07 is deleted and replaced with
             1027      the following:]
             1028      ["Number] [Title] [Referenced in code section
number
]
             1029      [14-10] [Installation of Standpipe and Hose
System
]
[905.2, 905.3.4, 905.6.2, 905.8"]
             1030          [(16) In IBC, Chapter 35, NFPA referenced standard 17-02 is deleted and replaced with
             1031      the following:]
             1032      ["Number] [Title] [Referenced in code section
number
]
             1033      [17-09] [Dry chemical Extinguishing Systems] [904.5, 904.11"]
             1034          [(17) In IBC, Chapter 35, NFPA referenced standard 17A-02 is deleted and replaced
             1035      with the following:]
             1036      ["Number] [Title] [Referenced in code section
number
]
             1037      [17A-09] [Wet Chemical Extinguishing System] [904.5, 904.11"]
             1038          [(18) In IBC, Chapter 35, NFPA referenced standard 20-07 is deleted and replaced with
             1039      the following:]
             1040      ["Number] [Title] [Referenced in code section
number
]
             1041      [20-10] [Installation of Stationary Pumps for
Fire Protection
]
[913.1, 913.2.1, 913.5"]
             1042          [(19) In IBC, Chapter 35, NFPA referenced standard 72-07 is deleted and replaced with
             1043      the following:]
             1044      ["Number] [Title] [Referenced in code section
number
]
             1045      [72-10] [National Fire Alarm Code ] [901.6, 903.4.1, 904.3.5, 907.2,
907.2.5, 907.2.11, 907.2.13.2,
907.3, 907.3.3, 907.3.4,
907.5.2.1.2, 907.5.3.3, 907.6,
907.6.1, 907.6.5, 907.7, 907.7.1,
907.7.2, 911.1.5, 3006.5, 3007.6"
]
             1046          [(20) In IBC, Chapter 35, NFPA referenced standard 92B-05 is deleted and replaced


             1047      with the following:]
             1048      ["Number] [Title] [Referenced in code section
number
]
             1049      [92B-09] [Smoke Management Systems in
Malls, Atria and Large Spaces
]
[909.8"]
             1050          [(21) In IBC, Chapter 35, NFPA referenced standard 101-06 is deleted and replaced
             1051      with the following:]
             1052      ["Number] [Title] [Referenced in code section
number
]
             1053      [101-09] [Line Safety Code] [1028.6.2"]
             1054          [(22) In IBC, Chapter 35, NFPA referenced standard 110-05 is deleted and replaced
             1055      with the following:]
             1056      ["Number] [Title] [Referenced in code section
number
]
             1057      [110-10] [Emergency and Standby Power
Systems
]
[2702.1"]

             1058          Section 12. Section 15A-3-202 is amended to read:
             1059     
Part 2. Statewide Amendments to IRC

             1060           15A-3-202. Amendments to Chapters 1 through 5 of IRC.
             1061          (1) In IRC, Section R102, a new Section R102.7.2 is added as follows: "R102.7.2
             1062      Physical change for bedroom window egress in legal nonconforming rental housing use. A
             1063      structure classified as a legal nonconforming rental housing use, whose egress bedroom
             1064      window is smaller than required by this code, is not required to undergo a physical change to
             1065      conform to this code if the change would compromise the structural integrity of the building or
             1066      could not be completed in accordance with other applicable requirements of this code,
             1067      including setback and window well requirements."
             1068          (2) In IRC, Section 109:
             1069          (a) A new IRC, Section 109.1.5, is added as follows: "R109.1.5 Weather-resistant
             1070      exterior wall envelope inspections. An inspection shall be made of the weather-resistant


             1071      exterior wall envelope as required by Section R703.1 and flashings as required by Section
             1072      R703.8 to prevent water from entering the weather-resistive barrier."
             1073          (b) The remaining sections are renumbered as follows: R109.1.6 Other inspections;
             1074      R109.1.6.1 Fire- and smoke-resistance-rated construction inspection; R109.1.6.2 Reinforced
             1075      masonry, insulating concrete form (ICF) and conventionally formed concrete wall inspection;
             1076      and R109.1.7 Final inspection.
             1077          (3) IRC, Section R114.1, is deleted and replaced with the following: "R114.1 Notice to
             1078      owner. Upon notice from the building official that work on any building or structure is being
             1079      prosecuted contrary to the provisions of this code or other pertinent laws or ordinances or in an
             1080      unsafe and dangerous manner, such work shall be immediately stopped. The stop work order
             1081      shall be in writing and shall be given to the owner of the property involved, or to the owner's
             1082      agent or to the person doing the work; and shall state the conditions under which work will be
             1083      permitted to resume."
             1084          (4) In IRC, Section R202, the following definition is added: "CERTIFIED
             1085      BACKFLOW PREVENTER ASSEMBLY TESTER: A person who has shown competence to
             1086      test Backflow prevention assemblies to the satisfaction of the authority having jurisdiction
             1087      under Utah Code, Subsection 19-4-104 (4)."
             1088          (5) In IRC, Section R202, the definition for "CONDITIONED SPACE" is modified by
             1089      deleting the words at the end of the sentence "being heated or cooled by any equipment or
             1090      appliance" and replacing them with the following: "enclosed within the building thermal
             1091      envelope that is directly heated or cooled, or indirectly heated or cooled by any of the following
             1092      means:
             1093      1. Openings directly into an adjacent conditioned space.
             1094      2. An un-insulated floor, ceiling or wall adjacent to a conditioned space.
             1095      3. Un-insulated duct, piping or other heat or cooling source within the space."
             1096          [(5)] (6) In IRC, Section R202, the definition of "Cross Connection" is deleted and
             1097      replaced with the following: "CROSS CONNECTION. Any physical connection or potential
             1098      connection or arrangement between two otherwise separate piping systems, one of which
             1099      contains potable water and the other either water of unknown or questionable safety or steam,
             1100      gas, or chemical, whereby there exists the possibility for flow from one system to the other,
             1101      with the direction of flow depending on the pressure differential between the two systems (see


             1102      "Backflow, Water Distribution")."
             1103          (7) In IRC, Section 202, in the definition for gray water a comma is inserted after the
             1104      word "washers"; the word "and" is deleted; and the following is added to the end: "and clear
             1105      water wastes which have a pH of 6.0 to 9.0; are non-flammable; non-combustible; without
             1106      objectionable odors; non-highly pigmented; and will not interfere with the operation of the
             1107      sewer treatment facility."
             1108          [(6)] (8) In IRC, Section R202, the definition of "Potable Water" is deleted and
             1109      replaced with the following: "POTABLE WATER. Water free from impurities present in
             1110      amounts sufficient to cause disease or harmful physiological effects and conforming to the
             1111      Utah Code, Title 19, Chapters 4, Safe Drinking Water Act, and 5, Water Quality Act, and the
             1112      regulations of the public health authority having jurisdiction."
             1113          [(7)] (9) IRC, Figure R301.2(5), is deleted and replaced with Table R301.2(5a) and
             1114      Table R301.2(5b) as follows:
             1115     
"TABLE NO. R301.2(5a)
             1116     
STATE OF UTAH - REGIONAL SNOW LOAD FACTORS
             1117      COUNTY Po S Ao
             1118      Beaver 43 63 6.2
             1119      Box Elder 43 63 5.2
             1120      Cache 50 63 4.5
             1121      Carbon 43 63 5.2
             1122      Daggett 43 63 6.5
             1123      Davis 43 63 4.5
             1124      Duchesne 43 63 6.5
             1125      Emery 43 63 6.0
             1126      Garfield 43 63 6.0
             1127      Grand 36 63 6.5
             1128      Iron 43 63 5.8
             1129      Juab 43 63 5.2
             1130      Kane 36 63 5.7
             1131      Millard 43 63 5.3
             1132      Morgan 57 63 4.5
             1133      Piute 43 63 6.2
             1134      Rich 57 63 4.1
             1135      Salt Lake 43 63 4.5
             1136      San Juan 43 63 6.5
             1137      Sanpete 43 63 5.2
             1138      Sevier 43 63 6.0
             1139      Summit 86 63 5.0
             1140      Tooele 43 63 4.5
             1141      Uintah 43 63 7.0
             1142      Utah 43 63 4.5
             1143      Wasatch 86 63 5.0
             1144      Washington 29 63 6.0
             1145      Wayne 36 63 6.5
             1146      Weber 43 63 4.5
             1147     
[TABLE NO. R301.2(5b)]
             1148     
[RECOMMENDED SNOW LOADS FOR SELECTED UTAH CITIES AND TOWNS(2)]
             1149      [Roof Snow
Load (PSF)
]
[Ground Snow
Load (PSF)
]
             1150      [Beaver County]
             1151          [Beaver] [5,920 ft.] [43] [62]
             1152      [Box Elder County]
             1153          [Brigham City] [4,300 ft.] [30] [43]
             1154          [Tremonton] [4,290 ft.] [30] [43]
             1155      [Cache County]
             1156          [Logan] [4,530 ft.] [35] [50]
             1157          [Smithfield] [4,595 ft.] [35] [50]
             1158      [Carbon County]
             1159          [Price] [5,550 ft.] [30] [43]
             1160      [Daggett County]
             1161          [Manila] [5,377 ft.] [30] [43]
             1162      [Davis County]
             1163          [Bountiful] [4,300 ft.] [30] [43]
             1164          [Farmington] [4,270 ft.] [30] [43]
             1165          [Layton] [4,400 ft.] [30] [43]
             1166          [Fruit Heights] [4,500 ft.] [40] [57]
             1167      [Duchesne County]
             1168          [Duchesne] [5,510 ft.] [30] [43]
             1169          [Roosevelt] [5,104 ft.] [30] [43]
             1170      [Emery County]
             1171          [Castle Dale] [5,660 ft.] [30] [43]
             1172          [Green River] [4,070 ft.] [25] [36]
             1173      [Garfield County]
             1174          [Panguitch] [6,600 ft.] [30] [43]
             1175      [Grand County]
             1176          [Moab] [3,965 ft.] [25] [36]
             1177      [Iron County]
             1178          [Cedar City] [5,831 ft.] [30] [43]
             1179      [Juab County]
             1180          [Nephi] [5,130 ft.] [30] [43]
             1181      [Kane County]
             1182          [Kanab] [5,000 ft.] [25] [36]
             1183      [Millard County]
             1184          [Fillmore] [5,000 ft.] [30] [43]
             1185          [Delta] [4,623 ft.] [30] [43]
             1186      [Morgan County]
             1187          [Morgan] [5,064 ft.] [40] [57]
             1188      [Piute County]
             1189          [Piute] [5,996 ft.] [30] [43]
             1190      [Rich County]
             1191          [Woodruff] [6,315 ft.] [40] [57]
             1192      [Salt Lake County]
             1193          [Murray] [4,325 ft.] [30] [43]
             1194          [Salt Lake City] [4,300 ft.] [30] [43]
             1195          [Sandy] [4,500 ft.] [30] [43]
             1196          [West Jordan] [4,375 ft.] [30] [43]
             1197          [West Valley] [4,250 ft.] [30] [43]
             1198      [San Juan County]
             1199          [Blanding] [6,200 ft.] [30] [43]
             1200          [Monticello] [6,820 ft.] [35] [50]
             1201      [Sanpete County]
             1202          [Fairview] [6,750 ft.] [35] [50]
             1203          [Mt. Pleasant] [5,900 ft.] [30] [43]
             1204          [Manti] [5,740 ft.] [30] [43]
             1205          [Ephraim] [5,540 ft.] [30] [43]
             1206          [Gunnison] [5,145 ft.] [30] [43]
             1207      [Sevier County]
             1208          [Salina] [5,130 ft.] [30] [43]
             1209          [Richfield] [5,270 ft.] [30] [43]
             1210      [Summit County]
             1211          [Coalville] [5,600 ft.] [60] [86]
             1212          [Kamas] [6,500 ft.] [70] [100]
             1213          [Park City] [6,800 ft.] [100] [142]
             1214          [Park City] [8,400 ft.] [162] [231]
             1215          [Summit Park] [7,200 ft.] [90] [128]
             1216      [Tooele County]
             1217          [Tooele] [5,100 ft.] [30] [43]
             1218      [Uintah County]
             1219          [Vernal] [5,280 ft.] [30] [43]
             1220      [Utah County]
             1221          [American Fork] [4,500 ft.] [30] [43]
             1222          [Orem] [4,650 ft.] [30] [43]
             1223          [Pleasant Grove] [5,000 ft.] [30] [43]
             1224          [Provo] [5,000 ft.] [30] [43]
             1225          [Spanish Fork] [4,720 ft.] [30] [43]
             1226      [Wasatch County]
             1227          [Heber] [5,630 ft.] [60] [86]
             1228      [Washington County]
             1229          [Central] [5,209 ft.] [25] [36]
             1230          [Dameron] [4,550 ft.] [25] [36]
             1231          [Leeds] [3,460 ft.] [20] [29]
             1232          [Rockville] [3,700 ft.] [25] [36]
             1233          [Santa Clara] [2,850 ft.] [15 (1)] [21]
             1234          [St. George] [2,750 ft.] [15 (1)] [21]
             1235      [Wayne County]
             1236          [Loa] [7,080 ft.] [30] [43]
             1237          [Hanksville] [4,308 ft.] [25] [36]
             1238      [Weber County]
             1239          [North Ogden] [4,500 ft.] [40] [57]
             1240          [Ogden] [4,350 ft.] [30] [43]
             1241      [NOTES]
             1242      [(1) The IRC requires a minimum live load - See R301.6.]
             1243      [(2) This table is informational only in that actual site elevations may vary. Table is only
valid if site elevation is within 100 feet of the listed elevation."
]
             1244     
TABLE NO. R301.2(5b)
             1245     
REQUIRED SNOW LOADS FOR SELECTED UTAH CITIES AND TOWNS1,2
             1246      The following jurisdictions require design snow load values that differ from the Equation in
the Utah Snow Load Study.
             1247      County City Elevation Ground Snow
Load (psf)
Roof Snow
Load (psf) 6
             1248      Carbon Price3
All other county locations5
5550
--
43
--
30
--
             1249      Davis Fruit Heights3 4500 - 4850 57 40
             1250      Emery Green River3 4070 36 25
             1251      Garfield Panguitch3 6600 43 30
             1252      Rich Woodruff3
Laketown4
Garden City5
Randolph4
6315
6000
--
6300
57
57
--
57
40
40
--
40
             1253      San Juan Monticello3 6820 50 35
             1254      Summit Coalville3
Kamas4
5600
6500
86
114
60
80
             1255      Tooele Tooele3 5100 43 30
             1256      Utah Orem3
Pleasant Grove4
Provo5
4650
5000
--
43
43
--
30
30
--
             1257      Wasatch Heber5 -- -- --
             1258      Washington Leeds3
Santa Clara3
St. George3
All other county locations5
3460

2850

2750

--
29
21
21
--
20
15
15
--
             1259      Wayne Loa3
7080
43 30
             1260      1The IRC requires a minimum live load _ See R301.6.
             1261      2This table is informational only in that actual site elevations may vary. Table is only valid if
site elevation is within 100 feet of the listed elevation. Otherwise, contact the local Building
Official.
             1262      3Values adopted form Table VII of the Utah Snow Load Study
             1263      4Values based on site-specific study. Contact local Building Official for additional
information.
             1264      5Contact local Building Official.
             1265      6Based on Ce =1.0, Ct =1.0 and Is =1.0"
             1266          [(8)] (10) IRC, Section R301.6, is deleted and replaced with the following: "R301.6
             1267      Utah Snow Loads. The snow loads specified in Table R301.2(5b) shall be used for the
             1268      jurisdictions identified in that table. Otherwise, the ground snow load, Pg, to be used in the
             1269      determination of design snow loads for buildings and other structures shall be determined by
             1270      using the following formula: Pg = (Po2 + S2(A-Ao)2)0.5 for A greater than Ao, and Pg = Po for A
             1271      less than or equal to Ao.
             1272      WHERE:
             1273      Pg = Ground snow load at a given elevation (psf);
             1274      Po = Base ground snow load (psf) from Table No. R301.2(5a);
             1275      S = Change in ground snow load with elevation (psf/100 ft.) From Table No. R301.2(5a);
             1276      A = Elevation above sea level at the site (ft./1,000);
             1277      Ao = Base ground snow elevation from Table R301.2(5a) (ft./1,000).
             1278      The building official may round the roof snow load to the nearest 5 psf. The ground snow
             1279      load, Pg, may be adjusted by the building official when a licensed engineer or architect submits
             1280      data substantiating the adjustments. [A record of such action together with the substantiating
             1281      data shall be provided to the division for a permanent record.


             1282      The building official may also directly adopt roof snow loads in accordance with Table
             1283      R301.2(5b), provided the site is no more than 100 ft. higher than the listed elevation.]
             1284      Where the minimum roof live load in accordance with Table R301.6 is greater than the design
             1285      roof snow load, such roof live load shall be used for design, however, it shall not be reduced to
             1286      a load lower than the design roof snow load. Drifting need not be considered for roof snow
             1287      loads less than 20 psf."
             1288          [(9)] (11) In IRC, Section R302.2, the words "Exception: A" are deleted and replaced
             1289      with the following:
             1290      "Exceptions:
             1291      1. A common 2-hour fire-resistance-rated wall is permitted for townhouses if such walls do
             1292      not contain plumbing or mechanical equipment, ducts or vents in the cavity of the common
             1293      wall. Electrical installation shall be installed in accordance with Chapters 34 through 43.
             1294      Penetrations of electrical outlet boxes shall be in accordance with Section R302.4.
             1295      2. In buildings equipped with an automatic residential fire sprinkler system, a".
             1296          [(10)] (12) In IRC, Section R302.2.4, a new exception 6 is added as follows: "6.
             1297      Townhouses separated by a common 2-hour fire-resistance-rated wall as provided in Section
             1298      R302.2."
             1299          (13) In IRC, Section R302.5.1, the words "self-closing device" are deleted and replaced
             1300      with "self-latching hardware".
             1301          (14) In IRC, Section R303.4, the number "5" is changed to "3" in the first sentence.
             1302          [(11)] (15) IRC, Sections R311.7.4 through R311.7.4.3, are deleted and replaced with
             1303      the following: "R311.7.4 Stair treads and risers. R311.7.4.1 Riser height. The maximum riser
             1304      height shall be 8 inches (203 mm). The riser shall be measured vertically between leading
             1305      edges of the adjacent treads. The greatest riser height within any flight of stairs shall not
             1306      exceed the smallest by more than 3/8 inch (9.5 mm).
             1307      R311.7.4.2 Tread depth. The minimum tread depth shall be 9 inches (228 mm). The tread
             1308      depth shall be measured horizontally between the vertical planes of the foremost projection of
             1309      adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within
             1310      any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Winder
             1311      treads shall have a minimum tread depth of 10 inches (254 mm) measured as above at a point
             1312      12 inches (305 mm) from the side where the treads are narrower. Winder treads shall have a


             1313      minimum tread depth of 6 inches (152 mm) at any point. Within any flight of stairs, the
             1314      greatest winder tread depth at the 12-inch (305 mm) walk line shall not exceed the smallest by
             1315      more than 3/8 inch (9.5 mm).
             1316      R311.7.4.3 Profile. The radius of curvature at the leading edge of the tread shall be no greater
             1317      than 9/16 inch (14.3 mm). A nosing not less than 3/4 inch (19 mm) but not more than 1 1/4
             1318      inches (32 mm) shall be provided on stairways with solid risers. The greatest nosing projection
             1319      shall not exceed the smallest nosing projection by more than 3/8 inch (9.5 mm) between two
             1320      stories, including the nosing at the level of floors and landings. Beveling of nosing shall not
             1321      exceed 1/2 inch (12.7 mm). Risers shall be vertical or sloped from the underside of the leading
             1322      edge of the tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. Open
             1323      risers are permitted, provided that the opening between treads does not permit the passage of a
             1324      4-inch diameter (102 mm) sphere.
             1325      Exceptions.
             1326      1. A nosing is not required where the tread depth is a minimum of 10 inches (254 mm).
             1327      2. The opening between adjacent treads is not limited on stairs with a total rise of 30 inches
             1328      (762 mm) or less."
             1329          [(12)] (16) In IRC, Section [R312.2] R312.1.2, the words "adjacent fixed seating" are
             1330      deleted.
             1331          (17) IRC, Section R312.2, is deleted.
             1332          [(13)] (18) IRC, [Section R313, is] Sections R313.1 through R313.2.1, are deleted[.]
             1333      and replaced with the following: "R313.1 Design and installation. When installed, automatic
             1334      residential fire sprinkler systems for townhouses or one- and two-family dwellings shall be
             1335      designed and installed in accordance with Section P2904."
             1336          [(14) IRC, Section R315.1, is deleted and replaced with the following: "R315.1 Carbon
             1337      monoxide alarms. For new construction, a listed carbon monoxide alarm shall be installed on
             1338      each habitable level of dwelling units within which fuel-fired appliances are installed and in
             1339      dwelling units that have attached garages."]
             1340          [(15) IRC, Section R315.3, is deleted and replaced with the following: "R315.3 Alarm
             1341      requirements. Listed single- and multiple-station carbon monoxide alarms shall comply with
             1342      UL 2034 and shall be installed in accordance with the provision of this code and NFPA 720."]
             1343          (19) A new IRC, Section R315.5, is added as follows: "R315.5 Power source. Carbon


             1344      monoxide alarms shall receive their primary power from the building wiring when such wiring
             1345      is served from a commercial source, and when primary power is interrupted, shall receive
             1346      power from a battery. Wiring shall be permanent and without a disconnecting switch other
             1347      than those required for over-current protection.
             1348      Exceptions:
             1349      1. Carbon monoxide alarms shall be permitted to be battery operated when installed in
             1350      buildings without commercial power.
             1351      2. Hard wiring of carbon monoxide alarms in existing areas shall not be required where the
             1352      alterations or repairs do no result in the removal of interior wall or ceiling finishes exposing the
             1353      structure, unless there is an attic, crawl space or basement available which could provide access
             1354      for hard wiring, without the removal of interior finishes."
             1355          (20) A new IRC, Section R315.6, is added as follows: "R315.6 Interconnection.
             1356      Where more than one carbon monoxide alarm is required to be installed within an individual
             1357      dwelling unit in accordance with Section R315.1, the alarm devices shall be interconnected in
             1358      such a manner that the actuation of one alarm will activate all of the alarms in the individual
             1359      unit. Physical interconnection of smoke alarms shall not be required where listed wireless
             1360      alarms are installed and all alarms sound upon activation of one alarm.
             1361      Exception: Interconnection of carbon monoxide alarms in existing areas shall not be required
             1362      where alterations or repairs do not result in removal of interior wall or ceiling finishes exposing
             1363      the structure, unless there is an attic, crawl space or basement available which could provide
             1364      access for interconnection without the removal of interior finishes."
             1365          [(16)] (21) In IRC, Section R403.1.6, a new Exception 4 is added as follows: "4.
             1366      When anchor bolt spacing does not exceed 32 inches (813 mm) apart, anchor bolts may be
             1367      placed with a minimum of two bolts per plate section located not less than 4 inches (102 mm)
             1368      from each end of each plate section at interior bearing walls, interior braced wall lines, and at
             1369      all exterior walls."
             1370          [(17)] (22) In IRC, Section R403.1.6.1, a new exception is added at the end of Item 2
             1371      and Item 3 as follows: "Exception: When anchor bolt spacing does not exceed 32 inches (816
             1372      mm) apart, anchor bolts may be placed with a minimum of two bolts per plate section located
             1373      not less than 4 inches (102 mm) from each end of each plate section at interior bearing walls,
             1374      interior braced wall lines, and at all exterior walls."


             1375          [(18)] (23) In IRC, Section R404.1, a new exception is added as follows: "Exception:
             1376      As an alternative to complying with Sections R404.1 through R404.1.5.3, concrete and
             1377      masonry foundation walls may be designed in accordance with IBC Sections 1807.1.5 and
             1378      1807.1.6 as amended in Section 1807.1.6.4 and Table 1807.1.6.4 under these rules."
             1379          (24) IRC, Section R501.3, is deleted.
             1380          Section 13. Section 15A-3-204 is amended to read:
             1381           15A-3-204. Amendments to Chapters 16 through 25 of IRC.
             1382          (1) In IRC, Table M1601.1.1(2), in the section "Round ducts and enclosed rectangular
             1383      ducts", the word "enclosed" is deleted; the words "14 inches or less" are deleted and replaced
             1384      with "over 8 inches but less than 15 inches"; the wording "8 inches or less" under duct size,
             1385      "0.013" under minimum thickness (in.), "30" under equivalent gage no., and "0.0159" under
             1386      aluminum minimum thickness (in.), are added; and the section "Exposed rectangular ducts" is
             1387      deleted.
             1388          (2) In IRC, Section M1901.3, the word "only" is inserted between the words "labeled"
             1389      and "for".
             1390          (3) A new IRC, Section G2401.2, is added as follows: "G2401.2 Meter Protection.
             1391      Fuel gas services shall be in an approved location and/or provided with structures designed to
             1392      protect the fuel gas meter and surrounding piping from physical damage, including falling,
             1393      moving, or migrating ice and snow. If an added structure is used, it must provide access for
             1394      service and comply with the IBC or the IRC."
             1395          Section 14. Section 15A-3-205 is amended to read:
             1396           15A-3-205. Amendments to Chapters 26 through 35 of IRC.
             1397          (1) A new IRC, Section P2602.3, is added as follows: "P2602.3 Individual water
             1398      supply. Where a potable public water supply is not available, individual sources of potable
             1399      water supply shall be utilized, provided that the source has been developed in accordance with
             1400      Utah Code, Sections 73-3-1 and 73-3-25 , as administered by the Department of Natural
             1401      Resources, Division of Water Rights. In addition, the quality of the water shall be approved by
             1402      the local health department having jurisdiction."
             1403          (2) A new IRC, Section P2602.4, is added as follows: "P2602.4 Sewer required. Every
             1404      building in which plumbing fixtures are installed and all premises having drainage piping shall
             1405      be connected to a public sewer where the sewer is accessible and is within 300 feet of the


             1406      property line in accordance with Utah Code, Section 10-8-38 ; or an approved private sewage
             1407      disposal system in accordance with Utah Administrative Code, Chapter 4, Rule R317, as
             1408      administered by the Department of Environmental Quality, Division of Water Quality."
             1409          (3) In IRC, Section P2801.7, [the word "townhouses" is] all words in the first sentence
             1410      up to the word "water" are deleted.
             1411          (4) A new IRC, Section P2902.1.1, is added as follows: "P2902.1.1 Backflow assembly
             1412      testing. The premise owner or his designee shall have backflow prevention assemblies
             1413      operation tested at the time of installation, repair, and relocation and at least on an annual basis
             1414      thereafter, or more frequently as required by the authority having jurisdiction. Testing shall be
             1415      performed by a Certified Backflow Preventer Assembly Tester. The assemblies that are subject
             1416      to this paragraph are the Spill Resistant Vacuum Breaker, the Pressure Vacuum Breaker
             1417      Assembly, the Double Check Backflow Prevention Assembly, the Double Check Detector
             1418      Assembly Backflow Preventer, the Reduced Pressure Principle Backflow Preventer, and
             1419      Reduced Pressure Detector Assembly."
             1420          (5) IRC, Table P2902.3, is deleted and replaced with the following:
             1421     
["TABLE P2902.3]
             1422     
[General Methods of Protection]
             1423      [Assembly
(applicable
standard)
]
[Degree of
Hazard
]
[Application] [Installation Criteria]
             1424      [Reduced Pressure
Principle Backflow
Preventer
]
([AWWA C511,
USC-FCCCHR,
ASSE 1013 CSA
CNA/CSA-B64.4)
and Reduced
Pressure Detector
Assembly
(ASSE 1047,
USC-FCCCHR)
]
[High or
Low
]
[Backpressure
or
Backsiphonage
]
[1/2" - 16"]
[a. The bottom of each RP assembly
shall be a minimum of 12 inches
above the ground or floor.
]
[b. RP assemblies shall NOT be
installed in a pit.
]
[c. The relief valve on each RP
assembly shall not be directly
connected to any waste disposal line,
including sanitary sewer, storm drains,
or vents.
]
[d. The assembly shall be installed in
a horizontal position only unless listed
or approved for vertical installation.
]
             1425      [Double Check
Backflow
Prevention
Assembly (AWWA
C510,
USC-FCCCHR,
ASSE 1015)
Double Check
Detector Assembly
Backflow Preventer
(ASSE 1048,
USC-FCCCHR)
]
[Low] [Backpressure
or
Backsiphonage
1/2" - 16"
]
[a. If installed in a pit, the DC
assembly shall be installed with a
minimum of 12 inches of clearance
between all sides of the vault
including the floor and roof or ceiling
with adequate room for testing and
maintenance.
]
[b. Shall be installed in a horizontal
position unless listed or approved for
vertical installation.
]
             1426      [Pressure Vacuum
Breaker Assembly
(ASSE 1020,
USC-FCCCHR)
]
[High or
Low
]
[Backsiphonage
1/2" - 2"
]
[a. Shall not be installed in an area
that could be subjected to
backpressure or back drainage
conditions.
]
[b. Shall be installed a minimum of
12 inches above all downstream
piping and the highest point of use.
]
[c. Shall not be installed below
ground or in a vault or pit.
]
[d. Shall be installed in a vertical
position only.
]
             1427      [Spill Resistant
Vacuum Breaker
(ASSE 1056,
USC-FCCCHR)
]
[High or
Low
]
[Backsiphonage
1/4" - 2"
]
[a. Shall not be installed in an area
that could be subjected to
backpressure or back drainage
conditions.
]
[b. Shall be installed a minimum of
12 inches above all downstream
piping and the highest point of use.
]
[c. Shall not be installed below
ground or in a vault or pit.
]
[d. Shall be installed in a vertical
position only.
]
             1428      [General
Installation
Criteria
]
[The assembly owner, when
necessary, shall provide devices or
structures to facilitate testing, repair,
and/or maintenance and to ensure the
safety of the backflow technician.
]
[Assemblies shall not be installed
more than five feet off the floor unless
a permanent platform is installed.
]
[The body of the assembly shall not be
closer than 12 inches to any wall,
ceiling or encumbrance, and shall be
accessible for testing, repair and/or
maintenance.
]
[In cold climates, assemblies shall be
protected from freezing by a means
acceptable to the code official.
]
[Assemblies shall be maintained as an
intact assembly."
]
             1429          [(6) IRC, Table 2902.3a, is added as follows:]
             1430     
["TABLE 2902.3a]
             1431     
[Specialty Backflow Devices for low hazard use only]
             1432      [Device] [Degree of
Hazard
]
[Application] [Applicable
Standard
]
             1433      [Air Gap] [High or
Low
]
[Backsiphonage] [See Table
P2902.3.1 ASME
A112.1.2
]
             1434      [Antisiphon-type
Water Closet
Flush Tank Ball
Cock
]
[Low] [Backsiphonage] [ASSE 1002
CSA CAN/
CSA-B125
]
             1435      [Atmospheric
Vacuum Breaker
]
[High or
Low
]
[Backsiphonage]
[a. Shall not be installed in an area
that could be subjected to
backpressure or back drainage
conditions.
]
[b. Shall not be installed where it
may be subjected to continuous
pressure for more than 12
consecutive hours at any time.
]
[c. Shall be installed a minimum of
six inches above all downstream
piping and the highest point of use.
]
[d. Shall be installed on the
discharge (downstream) side of any
valves.
]
[e. The AVB shall be installed in a
vertical position only.
]
[ASSE 1001
USC-FCCCHR,
CSA CAN/
CSA-B64.1.1
]
             1436      [Dual check
valve Backflow
Preventer
]
[Low] [Backsiphonage or Backpressure
1/4" - 1"
]
[ASSE 1024]
             1437      [Backflow
Preventer with
Intermediate
Atmospheric
Vent
]
[Low
Residential
Boiler
]
[Backsiphonage or Backpressure
1/4" - 3/4"
]
[ASSE 1012
CSA CAN/
CSA-B64.3
]
             1438      [Dual check
valve type
Backflow
Preventer for
Carbonated
Beverage
Dispensers/Post
Mix Type
]
[Low] [Backsiphonage or Backpressure
1/4" - 3/8"
]
[ASSE 1022]
             1439      [Hose-connection
Vacuum Breaker
]
[Low] [Backsiphonage
1/2", 3/4", 1"
]
[ASSE 1011
CSA CAN/
CSA-B64.2
]
             1440      [Vacuum Breaker
Wall Hydrants,
Frost-resistant,
Automatic
Draining Type
]
[Low] [Backsiphonage
3/4", 1"
]
[ASSE 1019
CSA CAN/
CSA-B64.2.2
]
             1441      [Laboratory
Faucet Backflow
Preventer
]
[Low] [Backsiphonage] [ASSE 1035
CSA CAN/
CSA-B64.7
]
             1442      [Hose
Connection
Backflow
Preventer
]
[Low] [Backsiphonage
1/2" - 1"
]
[ASSE 1052]
             1443      [Installation Guidelines: The above specialty devices shall be installed in accordance with
their listing and the manufacturer's instructions and the specific provisions of this chapter."
]
             1444      "DEVICE DEGREE OF
HAZARDa
APPLICATIONb APPLICABLE
STANDARDS
             1445      BACKFLOW PREVENTION ASSEMBLIES:
             1446      Double check backflow
prevention assembly
and double check fire
protection backflow
prevention assembly

Low hazard Backpressure or
backsiphonage
Sizes 3/8" - 16"
ASSE 1015,
AWWA C510,
CSA B64.5, CSA
B64.5.1
             1447      Double check detector
fire protection
backflow prevention
assemblies
Low hazard
Backpressure or
backsiphonage
Sizes 3/8" - 16"
ASSE 1048
             1448      Pressure vacuum
breaker assembly
High or low hazard Backsiphonage only
Sizes 1/2" - 2"
ASSE 1020, CSA
B64.1.2
             1449      Reduced pressure
principle backflow
prevention assembly
and reduced pressure
principle fire
protection backflow
assembly
High or low hazard Backpressure or
backsiphonage
Sizes 3/8" _ 16"
ASSE 1013,
AWWA C511,
CSA B64.4, CSA
B64.4.1
             1450      Reduced pressure
detector fire protection
backflow prevention
assemblies
High or low hazard Backpressure or
backsiphonage (Fire
Sprinkler Systems)
ASSE 1047
             1451      Spill-resistant vacuum
breaker assembly
High or low hazard Backsiphonage only
Sizes 1/2" - 2"
ASSE 1056
             1452      BACKFLOW PREVENTER PLUMBING DEVICES:
             1453      Antisiphon-type fill
valves for gravity water
closet flush tanks
High hazard Backsiphonage only ASSE 1002, CSA
B125.3
             1454      Backflow preventer for
carbonated beverage
machines
Low hazard Backpressure or
backsiphonage
Sizes 1/4" _ 3/8"
ASSE 1022
             1455      Backflow preventer
with intermediate
atmospheric vents
Low hazard Backpressure or
backsiphonage
Sizes 1/4" _ 3/8"
ASSE 1012, CSA
B64.3
             1456      Dual check valve type
backflow preventers
Low hazard Backpressure or
backsiphonage Sizes
1/4"-1"
ASSE 1024, CSA
B64.6
             1457      Hose connection
backflow preventer
High or low hazard Backsiphonage only
Sizes1/2"- 1"
ASSE 1052, CSA
B64.2, B64.2.1
             1458      Hose connection
vacuum breaker
High or low hazard Backsiphonage only
Sizes 1/2", 3/4", 1"
ASSE 1011,
CAN/CSA B64.1.1
             1459      Atmospheric type
vacuum breaker
High or low hazard Backsiphonage only
Sizes 1/2" - 4"
ASSE 1001, CSA
B64.1.1
             1460      Vacuum breaker wall
hydrants, frost
resistant, automatic
draining type
High or low hazard Backsiphonage only
Sizes 3/4", 1"
ASSE 1019, CSA
B64.2.2
             1461      OTHER MEANS or METHODS:
             1462      Air gap High or low hazard Backsiphonage only ASME A112.1.2
             1463      Air gap fittings for use
with plumbing fixtures,
appliances and
appurtenances
High or low hazard Backpressure or
backsiphonage
ASME A112.1.3
             1464      For SI: 1 inch = 25.4 mm
             1465      a. Low Hazard - See Pollution (Section 202), High Hazard - See Contamination (Section
202)
             1466      b. See Backpressure (Section 202), See Backpressure, low head (Section 202), See
Backsiphonage Section 202)
             1467      Installation Guidelines: The above specialty devices shall be installed in accordance with
their listing and the manufacturer's instructions and the specific provisions of this chapter."
             1468          (6) In IRC, Section P3009.1, all words after the word "urinals" are deleted and the
             1469      following sentence is added at the end: "Gray water recycling systems for subsurface landscape
             1470      irrigation shall conform with UAC R317-401 Gray Water Systems."
             1471          (7) A new IRC, Section P3009.1.1, is added as follows: "P3009.1.1 Recording. The
             1472      existence of a gray water recycling system shall be recorded on the deed of ownership for that
             1473      property. The certificate of occupancy shall not be issued until the documentation of the
             1474      recording required under this section is completed by the owner."
             1475          (8) In IRC, Section P3009.2, the words "and systems for subsurface landscape
             1476      irrigation shall comply with Section P3009.14" are deleted.
             1477          (9) IRC, Section P3009.6, is deleted and replaced with the following: "P3009.6 Potable
             1478      water connections. The potable water supply to any building utilizing a gray water recycling
             1479      system shall be protected against backflow by a reduced pressure backflow prevention
             1480      assembly installed in accordance with Section P2902."
             1481          (10) In IRC, Section P3009.7, the following is added at the end of the sentence: "and
             1482      other clear water wastes which have a pH of 6.0 to 9.0; are non-flammable, non-combustible;
             1483      without objectionable odor; non-highly pigmented; and will not interfere with the operation of
             1484      the sewer treatment facility."
             1485          (11) In IRC, Section P3009.13.3, in the second sentence, the following is added
             1486      between the words "backflow" and "in": "by a reduced pressure backflow prevention assembly
             1487      or an air gap installed".
             1488          (12) IRC, Section P3009.14, is deleted and replaced with the following: "Section
             1489      P3009.14 LANDSCAPE IRRIGATION SYSTEMS. Gray water recycling systems utilized for
             1490      subsurface irrigation for single family residences shall comply with the requirements of UAC
             1491      R317-401, Gray Water Systems. Gray water recycling systems utilized for subsurface
             1492      irrigation for other occupancies shall comply with UAC R317-3, Design Requirements for
             1493      Wastewater Collection, Treatment and Disposal and UAC R317-4, Onsite Waterwaste
             1494      Systems."


             1495          [(7)] (13) In IRC, Section P3103.6, the following sentence is added at the end of the
             1496      paragraph: "Vents extending through the wall shall terminate not less than 12 inches from the
             1497      wall with an elbow pointing downward."
             1498          [(8)] (14) In IRC, Section P3104.4, the following sentence is added at the end of the
             1499      paragraph: "Horizontal dry vents below the flood level rim shall be permitted for floor drain
             1500      and floor sink installations when installed below grade in accordance with Chapter 30, and
             1501      Sections P3104.2 and P3104.3. A wall cleanout shall be provided in the vertical vent."
             1502          Section 15. Section 15A-3-206 is amended to read:
             1503           15A-3-206. Amendments to Chapters 36 and 44 of IRC.
             1504          (1) In IRC, Section [E3902.11] E3902.12, the following words are deleted: "family
             1505      rooms, dining rooms, living rooms, parlors, libraries, dens, sunrooms, recreation rooms,
             1506      closets, hallways, and similar rooms or areas["].
             1507      Exception: This section does not apply for a simple move or an extension of a branch circuit or
             1508      an outlet which does not significantly increase the existing electrical load. This exception does
             1509      not include changes involving remodeling or additions to a residence."
             1510          (2) IRC, Chapter 44, is amended by adding the following reference standard:
             1511      "Standard reference
number
Title Referenced in code
section number
             1512      USC-FCCCHR [9th]
10th Edition Manual of
Cross Connection
Control
Foundation for Cross-Connection Control
and Hydraulic Research University of
Southern California Kaprielian Hall 300
Los Angeles CA 90089-2531
Table P2902.3"
             1513          [(3) In IRC, Chapter 44, the following standard is added under NFPA as follows:]
             1514      ["Standard reference
number
]
[Title] [Referenced in code
section number
]
             1515      [720-09] [Standard for the Installation of Carbon
Monoxide (CO) Detection and Warning
Equipment
]
[R315.3"]
             1516          [(4) IRC, Appendix O, Gray Water Recycling Systems, is deleted and replaced with
             1517      Appendix C of the International Plumbing Code as amended by the State Construction Code.]


             1518          Section 16. Section 15A-3-302 is amended to read:
             1519     
Part 3. Statewide Amendments to IPC

             1520           15A-3-302. Amendments to Chapters 1 and 2 of IPC.
             1521          (1) A new IPC, Section 101.2, is added as follows: "For clarification, the International
             1522      Private Sewage Disposal Code is not part of the plumbing code even though it is in the same
             1523      printed volume."
             1524          (2) In IPC, Section 202, the definition for "Backflow Backpressure, Low Head" is
             1525      deleted.
             1526          (3) In IPC, Section 202, the following definition is added: "Certified Backflow
             1527      Preventer Assembly Tester. A person who has shown competence to test Backflow prevention
             1528      assemblies to the satisfaction of the authority having jurisdiction under Utah Code, Subsection
             1529      19-4-104 (4)."
             1530          (4) In IPC, Section 202, the following definition is added: "Contamination (High
             1531      Hazard). An impairment of the quality of the potable water that creates an actual hazard to the
             1532      public health through poisoning or through the spread of disease by sewage, industrial fluids or
             1533      waste."
             1534          [(4)] (5) In IPC, Section 202, the definition for "Cross Connection" is deleted and
             1535      replaced with the following: "Cross Connection. Any physical connection or potential
             1536      connection or arrangement between two otherwise separate piping systems, one of which
             1537      contains potable water and the other either water of unknown or questionable safety or steam,
             1538      gas, or chemical, whereby there exists the possibility for flow from one system to the other,
             1539      with the direction of flow depending on the pressure differential between the two systems (see
             1540      "Backflow")."
             1541          (6) In IPC, Section 202, the following definition is added: "Deep Seal Trap. A
             1542      manufactured or field fabricated trap with a liquid seal of 4" or larger."
             1543          (7) In IPC, Section 202, in the definition for gray water a comma is inserted after the
             1544      word "washers"; the word "and" is deleted; and the following is added to the end: "and clear
             1545      water wastes which have a pH of 6.0 to 9.0; are non-flammable; non-combustible; without
             1546      objectionable odors; non-highly pigmented; and will not interfere with the operation of the
             1547      sewer treatment facility."
             1548          (8) In IPC, Section 202, the following definition is added: "High Hazard. See


             1549      Contamination."
             1550          (9) In IPC, Section 202, the following definition is added: "Low Hazard. See
             1551      Pollution."
             1552          (10) In IPC, Section 202, the following definition is added: "Pollution (Low Hazard).
             1553      An impairment of the quality of the potable water to a degree that does not create a hazard to
             1554      the public health but that does adversely and unreasonably affect the aesthetic qualities of such
             1555      potable water for domestic use."
             1556          [(5)] (11) In IPC, Section 202, the definition for "Potable Water" is deleted and
             1557      replaced with the following: "Potable Water. Water free from impurities present in amounts
             1558      sufficient to cause disease or harmful physiological effects and conforming to the Utah Code,
             1559      Title 19, Chapters 4, Safe Drinking Water Act, and 5, Water Quality Act, and the regulations of
             1560      the public health authority having jurisdiction."
             1561          Section 17. Section 15A-3-303 is amended to read:
             1562           15A-3-303. Amendments to Chapter 3 of IPC.
             1563          (1) In IPC, [Table 303.4, the item listed as "Backflow prevention devises" is modified
             1564      as follows] Section 303.4, the following exception is added:
             1565          [(a) in the Third-Party Certified field, after the word "Required" add "See footnote 1";]
             1566          [(b) in the Third-Party Tested field the following is added: "Required see footnote 1";
             1567      and]
             1568          [(c) a new footnote 1 is added as follows: "1.]
             1569      "Exception: Third-party certification for backflow prevention assemblies will consist of any
             1570      combination of two certifications, laboratory or field. Acceptable third party laboratory
             1571      certifying agencies are ASSE, IAPMO, and USC-FCCCHR. USC-FCCCHR currently
             1572      provides the only field testing of backflow protection assemblies. Also see
             1573      www.drinkingwater.utah.gov and Division of Drinking Water Rule, Utah Administrative Code,
             1574      R309-305-6."
             1575          (2) IPC, Section 304.3, Meter Boxes, is deleted.
             1576          (3) IPC, Section 311.1, is deleted.
             1577          [(4) IPC, Sections 312.10 through 312.10.2, are deleted and replaced with the
             1578      following: "312.10 Backflow assembly testing. The premise owner or his designee shall have
             1579      backflow prevention assemblies operation tested at the time of installation, repair, and


             1580      relocation and at least on an annual basis thereafter, or more frequently as required by the
             1581      authority having jurisdiction. Testing shall be performed by a Certified Backflow Preventer
             1582      Assembly Tester. The assemblies that are subject to this paragraph are the Spill Resistant
             1583      Vacuum Breaker, the Pressure Vacuum Breaker Assembly, the Double Check Backflow
             1584      Prevention Assembly, the Double Check Detector Assembly Backflow Preventer, the Reduced
             1585      Pressure Principle Backflow Preventer, and Reduced Pressure Detector Assembly."]
             1586          (4) In IPC, Section 312.3, the following is added at the end of the paragraph:
             1587          "Where water is not available at the construction site or where freezing conditions limit
             1588      the use of water on the construction site, plastic drainage and vent pipe may be permitted to be
             1589      tested with air. The following procedures shall be followed:
             1590      1. Contractor shall recognize that plastic is extremely brittle at lower temperatures and can
             1591      explode, causing serious injury or death.
             1592      2. Contractor assumes all liability for injury or death to persons or damage to property or for
             1593      claims for labor and/or material arising from any alleged failure of the system during testing
             1594      with air or compressed gasses.
             1595      3. Proper personal protective equipment, including safety eyewear and protective headgear,
             1596      should be worn by all individuals in any area where an air or gas test is being conducted.
             1597      4. Contractor shall take all precautions necessary to limit the pressure within the plastic piping.
             1598      5. No water supply system shall be pressurized in excess of 6 psi as measured by accurate
             1599      gauges graduated to no more than three times the test pressure.
             1600      6. The pressure gauge shall be monitored during the test period, which should not exceed 15
             1601      minutes.
             1602      7. At the conclusion of the test, the system shall be depressurized gradually, all trapped air or
             1603      gases should be vented, and test balls and plugs should be removed with caution."
             1604          (5) In IPC, Section 312.5, the following is added at the end of the paragraph:
             1605          "Where water is not available at the construction site or where freezing conditions limit
             1606      the use of water on the construction site, plastic water pipes may be permitted to be tested with
             1607      air. The following procedures shall be followed:
             1608      1. Contractor shall recognize that plastic is extremely brittle at lower temperatures and can
             1609      explode, causing serious injury or death.
             1610      2. Contractor assumes all liability for injury or death to persons or damage to property or for


             1611      claims for labor and/or material arising from any alleged failure of the system during testing
             1612      with air or compressed gasses.
             1613      3. Proper personal protective equipment, including safety eyewear and protective headgear,
             1614      should be worn by all individuals in any area where an air or gas test is being conducted.
             1615      4. Contractor shall take all precautions necessary to limit the pressure within the plastic piping.
             1616      5. Water supply systems shall be pressure tested to a minimum of 50 psi but not more than 80
             1617      psi as measured by accurate gauges graduated to no more than three times the test pressure.
             1618      6. The pressure gauge shall be monitored during the test period, which should not exceed 15
             1619      minutes.
             1620      7. At the conclusion of the test, the system shall be depressurized gradually, all trapped air or
             1621      gases should be vented, and test balls and plugs should be removed with caution."
             1622          (6) A new IPC, Section 312.10.3, is added as follows: "312.10.3 Tester Qualifications.
             1623      Testing shall be performed by a Utah Certified Backflow Preventer Assembly Tester in
             1624      accordance with Utah Administrative Code, R309-305."
             1625          Section 18. Section 15A-3-304 is amended to read:
             1626           15A-3-304. Amendments to Chapter 4 of IPC.
             1627          (1) In IPC, [Section] Table 403.1, [a new footnote g is added as follows:] the following
             1628      changes are made:
             1629          (a) The title for Table 403.1 is deleted and replaced with the following: "Table 403.1,
             1630      Minimum Number of Required Plumbing Facilitiesa, h";
             1631          (b) In the row for "E" occupancy in the field for "OTHER" a new footnote i is added.
             1632          (c) In the row for "I-4" occupancy in the field for "OTHER" a new footnote i is added.
             1633          (d) A new footnote h is added as follows: "FOOTNOTE: [g] h. When provided, in
             1634      public toilet facilities there shall be an equal number of diaper changing facilities in male toilet
             1635      rooms and female toilet rooms."
             1636          (e) A new footnote i is added to the table as follows: "FOOTNOTE i: Non-residential
             1637      child care facilities shall comply with additional sink requirements of Utah Administrative
             1638      Code R430-100-4."
             1639          (2) A new IPC, Section [406.4] 406.3, is added as follows: "[406.4] 406.3 Automatic
             1640      clothes washer safe pans. Safe pans, when installed under automatic clothes washers, shall be
             1641      installed in accordance with Section 504.7."


             1642          (3) A new IPC, Section 412.5, is added as follows: "412.5 Public toilet rooms. All
             1643      public toilet rooms shall be equipped with at least one floor drain."
             1644          Section 19. Section 15A-3-305 is amended to read:
             1645           15A-3-305. Amendments to Chapter 5 of IPC.
             1646          (1) IPC, Section 502.4, is deleted and replaced with the following: "502.4 Seismic
             1647      supports. Appliances designed to be fixed in position shall be fastened or anchored in an
             1648      approved manner. Water heaters shall be anchored or strapped to resist horizontal
             1649      displacement caused by earthquake motion. Strapping shall be at points within the upper
             1650      one-third and lower one-third of the appliance's vertical dimensions. At the lower point, the
             1651      strapping shall maintain a minimum distance of 4 inches (102 mm) above the controls."
             1652          [(1)] (2) In IPC, Section 504.7.2, the following is added at the end of the section:
             1653      "When permitted by the code official, the pan drain may be directly connected to a soil stack,
             1654      waste stack, or branch drain. The pan drain shall be individually trapped and vented as
             1655      required in Section 907.1. The pan drain shall not be directly or indirectly connected to any
             1656      vent. The trap shall be provided with a trap primer conforming to ASSE 1018 or ASSE 1044,
             1657      a barrier type floor drain trap seal protection device meeting ASSE 1072, or a deep seal p-trap."
             1658          [(2)] (3) A new IPC, Section 504.7.3, is added as follows: "504.7.3 Pan Designation.
             1659      A water heater pan shall be considered an emergency receptor designated to receive the
             1660      discharge of water from the water heater only and shall not receive the discharge from any
             1661      other fixtures, devises, or equipment."
             1662          Section 20. Section 15A-3-306 is amended to read:
             1663           15A-3-306. Amendments to Chapter 6 of IPC.
             1664          (1) IPC, Section 602.3, is deleted and replaced with the following: "602.3 Individual
             1665      water supply. Where a potable public water supply is not available, individual sources of
             1666      potable water supply shall be utilized provided that the source has been developed in
             1667      accordance with Utah Code, Sections 73-3-1 , 73-3-3 , and 73-3-25 , as administered by the
             1668      Department of Natural Resources, Division of Water Rights. In addition, the quality of the
             1669      water shall be approved by the local health department having jurisdiction. The source shall
             1670      supply sufficient quantity of water to comply with the requirements of this chapter."
             1671          (2) IPC, Sections 602.3.1, 602.3.2, 602.3.3, 602.3.4, 602.3.5, and 602.3.5.1, are
             1672      deleted.


             1673          (3) A new IPC, Section 604.4.1, is added as follows: "604.4.1 Manually operated
             1674      metering faucets. Self closing or manually operated metering faucets shall provide a flow of
             1675      water for at least 15 seconds without the need to reactivate the faucet."
             1676          (4) IPC, Section 606.5, is deleted and replaced with the following: "606.5 Water
             1677      pressure booster systems. Water pressure booster systems shall be provided as required by
             1678      Section 606.5.1 through 606.5.11."
             1679          (5) A new IPC, Section 606.5.11, is added as follows: "606.5.11 Prohibited
             1680      installation. In no case shall a booster pump be allowed that will lower the pressure in the
             1681      public main to less than [20 psi."] the minimum water pressure specified in Utah
             1682      Administrative Code R309-105-9."
             1683          (6) In IPC, Section 608.1, the words "and pollution" are added after the word
             1684      "contamination."
             1685          [(6)] (7) IPC, Table 608.1, is deleted and replaced with the following:
             1686     
["TABLE 608.1]
             1687     
[General Methods of Protection]
             1688      [Assembly
(applicable
standard)
]
[Degree of
Hazard
]
[Application] [Installation Criteria]
             1689      [Reduced Pressure
Principle Backflow
Preventer
(AWWA C511,
USC-FCCCHR,
ASSE 1013 CSA
CNA/CSA-B64.4)
and Reduced
Pressure Detector
Assembly
(ASSE 1047,
USC-FCCCHR)
]
[High or
Low
]
[Backpressure
or
Backsiphonage
1/2" - 16"
]
[a. The bottom of each RP
assembly shall be a minimum of 12
inches above the ground or floor.
]
[b. RP assemblies shall NOT be
installed in a pit.
]
[c. The relief valve on each RP
assembly shall not be directly
connected to any waste disposal
line, including sanitary sewer,
storm drains, or vents.
]
[d. The assembly shall be installed
in a horizontal position only unless
listed or approved for vertical
installation.
]
             1690      [Double Check
Backflow
Prevention
Assembly
(AWWA C510,
USC-FCCCHR,
ASSE 1015)
Double Check
Detector Assembly
Backflow Preventer
(ASSE 1048,
USC-FCCCHR)
]
[Low] [Backpressure
or
Backsiphonage
1/2" - 16"
]
[a. If installed in a pit, the DC
assembly shall be installed with a
minimum of 12 inches of clearance
between all sides of the vault
including the floor and roof or
ceiling with adequate room for
testing and maintenance.
]
[b. Shall be installed in a
horizontal position unless listed or
approved for vertical installation.
]
             1691      [Pressure Vacuum
Breaker Assembly
(ASSE 1020,
USC-FCCCHR)
]
[High or
Low
]
[Backsiphonage
1/2" - 2"
]
[a. Shall not be installed in an area
that could be subjected to
backpressure or back drainage
conditions.
]
[b. Shall be installed a minimum
of 12 inches above all downstream
piping and the highest point of
use.
]
[c. Shall not be installed below
ground or in a vault or pit.
]
[d. Shall be installed in a vertical
position only.
]
             1692      [Spill Resistant
Vacuum Breaker
(ASSE 1056,
USC-FCCCHR)
]
[High or
Low
]
[Backsiphonage
1/4" - 2"
]
[a. Shall not be installed in an area
that could be subjected to
backpressure or back drainage
conditions.
]
[b. Shall be installed a minimum
of 12 inches above all downstream
piping and the highest point of
use.
]
[c. Shall not be installed below
ground or in a vault or pit.
]
[d. Shall be installed in a vertical
position only.
]
             1693      [General
Installation
Criteria
]
[The assembly owner, when
necessary, shall provide devices or
structures to facilitate testing,
repair, and/or maintenance and to
ensure the safety of the backflow
technician.
]
[Assemblies shall not be installed
more than five feet off the floor
unless a permanent platform is
installed.
]
[The body of the assembly shall not
be closer than 12 inches, to any
wall, ceiling or encumbrance, and
shall be accessible for testing,
repair and/or maintenance.
]
[In cold climates, assemblies shall
be protected from freezing by a
means acceptable to the code
official.
]
[Assemblies shall be maintained as
an intact assembly."
]
             1694          [(7) IPC, Table 608.1.1, is added as follows:]
             1695     
["TABLE 608.1.1]
             1696     
[Specialty Backflow Devices for low hazard use only]
             1697      [Device] [Degree of
Hazard
]
[Application] [Applicable
Standard
]
             1698      [Air Gap] [High or
Low
]
[Backsiphonage] [See Table
608.15.1
ASME A112.1.2
]
             1699      [Antisiphon-type
Water Closet
Flush Tank Ball
Cock
]
[Low] [Backsiphonage] [ASSE 1002
CSA CAN/
CSA-B125
]
             1700      [Atmospheric
Vacuum Breaker
]
[High or
Low
]
[Backsiphonage]
[a. Shall not be installed in an area
that could be subjected to
backpressure or back drainage
conditions.
]
[b. Shall not be installed where it
may be subjected to continuous
pressure for more than 12
consecutive hours at any time.
]
[c. Shall be installed a minimum of
six inches above all downstream
piping and the highest point of
use.
]
[d. Shall be installed on the
discharge (downstream) side of any
valves.
]
[e. The AVB shall be installed in a
vertical position only.
]
[ASSE 1001
USC-FCCCHR,
CSA CAN/
CSA-B64.1.1
]
             1701      [Dual check
valve Backflow
Preventer
]
[Low] [Backsiphonage or Backpressure
1/4" - 1"
]
[ASSE 1024]
             1702      [Backflow
Preventer with
Intermediate
Atmospheric
Vent
]
[Low
Residential
Boiler
]
[Backsiphonage or Backpressure
1/4" - 3/4"
]
[ASSE 1012
CSA CAN/
CSA-B64.3
]
             1703      [Dual check
valve type
Backflow
Preventer for
Carbonated
Beverage
Dispensers/Post
Mix Type
]
[Low] [Backsiphonage or Backpressure
1/4" - 3/8"
]
[ASSE 1022]
             1704      [Hose-connection
Vacuum Breaker
]
[Low] [Backsiphonage
1/2", 3/4", 1"
]
[ASSE 1011
CSA CAN/
CSA-B64.2
]
             1705      [Vacuum Breaker
Wall Hydrants,
Frost-resistant,
Automatic
Draining Type
]
[Low] [Backsiphonage
3/4", 1"
]
[ASSE 1019
CSA CAN/
CSA-B64.2.2
]
             1706      [Laboratory
Faucet Backflow
Preventer
]
[Low] [Backsiphonage] [ASSE 1035
CSA CAN/
CSA-B64.7
]
             1707      [Hose
Connection
Backflow
Preventer
]
[Low] [Backsiphonage
1/2" - 1"
]
[ASSE 1052]
             1708      [Installation Guidelines: The above specialty devices shall be installed in accordance with
their listing and the manufacturer's instructions and the specific provisions of this chapter."
]
             1709     
"TABLE 608.1
             1710     
Application of Back Flow Preventers
             1711      DEVICE DEGREE OF
HAZARDa
APPLICATIONb APPLICABLE
STANDARDS
             1712      BACKFLOW PREVENTION ASSEMBLIES:
             1713      Double check backflow
prevention assembly
and double check fire
protection backflow
prevention assembly
Low hazard Backpressure or
backsiphonage
Sizes 3/8" - 16"
ASSE 1015,
AWWA C510,
CSA B64.5, CSA
B64.5.1
             1714      Double check detector
fire protection
backflow prevention
assemblies
Low hazard Backpressure or
backsiphonage
Sizes 3/8" - 16"
ASSE 1048
             1715      Pressure vacuum
breaker assembly
High or low hazard Backsiphonage only
Sizes 1/2" - 2"
ASSE 1020, CSA
B64.1.2
             1716      Reduced pressure
principle backflow
prevention assembly
and reduced pressure
principle fire
protection backflow
assembly
High or low hazard Backpressure or
backsiphonage
Sizes 3/8" _ 16"
ASSE 1013,
AWWA C511,
CSA B64.4, CSA
B64.4.1
             1717      Reduced pressure
detector fire protection
backflow prevention
assemblies
High or low hazard Backpressure or
backsiphonage (Fire
Sprinkler Systems)
ASSE 1047
             1718      Spill-resistant vacuum
breaker assembly
High or low hazard Backsiphonage only
Sizes 1/2" - 2"
ASSE 1056
             1719      BACKFLOW PREVENTER PLUMBING DEVICES:
             1720      Antisiphon-type fill
valves for gravity water
closet flush tanks
High hazard Backsiphonage only ASSE 1002, CSA
B125.3
             1721      Backflow preventer for
carbonated beverage
machines

Low hazard Backpressure or
backsiphonage
Sizes 1/4" - 3/8"
ASSE 1022
             1722      Backflow preventer
with intermediate
atmospheric vents
Low hazard Backpressure or
backsiphonage
Sizes 1/4" - 3/8"
ASSE 1012, CSA
B64.3
             1723      Dual check valve type
backflow preventers
Low hazard Backpressure or
backsiphonage Sizes
1/4"-1"
ASSE 1024, CSA
B64.6
             1724      Hose connection
backflow preventer
High or low hazard Backsiphonage only
Sizes1/2" - 1"
ASSE 1052, CSA
B64.2, B64.2.1
             1725      Hose connection
vacuum breaker
High or low hazard Backsiphonage only
Sizes 1/2", 3/4", 1"
ASSE 1011,
CAN/CSA B64.1.1
             1726      Atmospheric type
vacuum breaker
High or low hazard Backsiphonage only
Sizes 1/2" - 4"
ASSE 1001, CSA
B64.1.1
             1727      Vacuum breaker wall
hydrants, frost
resistant, automatic
draining type
High or low hazard Backsiphonage only
Sizes 3/4", 1"
ASSE 1019, CSA
B64.2.2
             1728      OTHER MEANS or METHODS:
             1729      Air gap High or low hazard Backsiphonage only ASME A112.1.2
             1730      Air gap fittings for use
with plumbing fixtures,
appliances and
appurtenances
High or low hazard Backpressure or
backsiphonage
ASME A112.1.3
             1731      For SI: 1 inch = 25.4 mm
             1732      a. Low Hazard - See Pollution (Section 202), High Hazard - See Contamination (Section
202)
             1733      b. See Backpressure (Section 202), See Backpressure, low head (Section 202), See
Backsiphonage Section 202)
             1734      Installation Guidelines: The above specialty devices shall be installed in accordance with
their listing and the manufacturer's instructions and the specific provisions of this chapter."
             1735          (8) In IPC, Section 608.3, the word "and" after the word "contamination" is deleted and
             1736      replaced with a comma and the words "and pollution" are added after the word "contamination"
             1737      in the first sentence.
             1738          (9) In IPC, Section 608.5, the words "with the potential to create a condition of either
             1739      contamination or pollution or" are added after the word "substances".
             1740          [(8)] (10) In IPC, Section 608.6, the following sentence is added at the end of the
             1741      paragraph: "Any connection between potable water piping and sewer-connected waste shall be
             1742      protected by an air gap in accordance with Section 308.13.1."
             1743          [(9)] (11) IPC, Section 608.7, is deleted[.] and replaced with the following: "608.7
             1744      Stop and Waste Valves installed below grade. Combination stop-and-waste valves shall be
             1745      permitted to be installed underground or below grade. Freeze proof yard hydrants that drain
             1746      the riser into the ground are considered to be stop-and-waste valves and shall be permitted."
             1747          [(10)] (12) In IPC, Section 608.11, the following sentence is added at the end of the
             1748      paragraph: "The coating and installation shall conform to NSF Standard 61 and application of
             1749      the coating shall comply with the manufacturer's instructions."
             1750          [(11)] (13) IPC, Section 608.13.3, is deleted and replaced with the following: "608.13.3
             1751      Backflow preventer with intermediate atmospheric vent. Backflow preventers with
             1752      intermediate atmospheric vents shall conform to ASSE 1012 or CSA CAN/CSA-B64.3. These
             1753      devices shall be permitted to be installed on residential boilers only, without chemical
             1754      treatment, where subject to continuous pressure conditions. The relief opening shall discharge
             1755      by air gap and shall be prevented from being submerged."
             1756          [(12)] (14) IPC, Section 608.13.4, is deleted.
             1757          [(13)] (15) IPC, Section 608.13.9, is deleted[.] and replaced with the following:
             1758      "608.13.9 Chemical dispenser backflow devices. Backflow devices for chemical dispensers
             1759      shall comply with Section 608.16.7."
             1760          [(14)] (16) IPC, Section 608.15.3, is deleted and replaced with the following: "608.15.3
             1761      Protection by a backflow preventer with intermediate atmospheric vent. Connections to


             1762      residential boilers only, without chemical treatment, shall be protected by a backflow preventer
             1763      with an intermediate atmospheric vent."
             1764          [(15)] (17) IPC, Section 608.15.4, is deleted and replaced with the following: "608.15.4
             1765      Protection by a vacuum breaker. Openings and outlets shall be protected by atmospheric-type
             1766      or pressure-type vacuum breakers. [The critical level of the atmospheric vacuum breaker shall
             1767      be set a minimum of 6 inches (152 mm) above the flood level rim of the fixture or device. The
             1768      critical level of the pressure vacuum breaker shall be set a minimum of 12 inches (304 mm)
             1769      above the flood level rim of the fixture or device.] Vacuum breakers shall not be installed
             1770      under exhaust hoods or similar locations that will contain toxic fumes or vapors. Fill valves
             1771      shall be set in accordance with Section 425.3.1. [Vacuum breakers shall not be installed under
             1772      exhaust hoods or similar locations that will contain toxic fumes or vapors.] Atmospheric
             1773      Vacuum Breakers - The critical level of the atmospheric vacuum breaker shall be set a
             1774      minimum of 6 inches (152 mm) above the flood level rim of the fixture or device.
             1775      Pipe-applied vacuum breakers shall be installed not less than 6 inches (152 mm) above the
             1776      flood level rim of the fixture, receptor, or device served. No valves shall be installed
             1777      downstream of the atmospheric vacuum breaker. Pressure Vacuum Breaker - The critical level
             1778      of the pressure vacuum breaker shall be set a minimum of 12 inches (304 mm) above the flood
             1779      level of the fixture or device."
             1780          [(16)] (18) In IPC, Section 608.15.4.2, the following is added after the first sentence:
             1781      "Add-on-backflow prevention devices shall be non-removable. In climates where freezing
             1782      temperatures occur, a listed self-draining frost proof hose bibb with an integral backflow
             1783      preventer shall be used."
             1784          [(17)] (19) In IPC, Section 608.16.2, [the first sentence of the paragraph] is deleted and
             1785      replaced as follows: "608.16.2 Connections to boilers. The potable [water supply to the
             1786      residential boiler only, without chemical treatment, shall be] supply to a boiler shall be
             1787      protected by an air gap or a reduced pressure principle backflow preventer, complying with
             1788      ASSE 1013, CSA B64.4 or AWWA C511.
             1789      Exception: The potable supply to a residential boiler without chemical treatment may be
             1790      equipped with a backflow preventer with an intermediate atmospheric vent complying with
             1791      ASSE 1012 or CSA CAN/CSA-B64.3."
             1792          [(18)] (20) IPC, Section 608.16.3, is deleted and replaced with the following: "608.16.3


             1793      Heat exchangers. Heat exchangers shall be separated from potable water by double-wall
             1794      construction. An air gap open to the atmosphere shall be provided between the two walls.
             1795      Exceptions:
             1796      1. Single wall heat exchangers shall be permitted when all of the following conditions are met:
             1797      a. It utilizes a heat transfer medium of potable water or contains only substances which are
             1798      recognized as safe by the United States Food and Drug Administration (FDA);
             1799      b. The pressure of the heat transfer medium is maintained less than the normal minimum
             1800      operating pressure of the potable water system; and
             1801      c. The equipment is permanently labeled to indicate only additives recognized as safe by the
             1802      FDA shall be used.
             1803      2. Steam systems that comply with paragraph 1 above.
             1804      3. Approved listed electrical drinking water coolers."
             1805          [(19)] (21) In IPC, Section 608.16.4.1, a new exception is added as follows:
             1806      "Exception: All class 1 and 2 systems containing chemical additives consisting of strictly
             1807      glycerine (C.P. or U.S.P. 96.5 percent grade) or propylene glycol shall be protected against
             1808      backflow with a double check valve assembly. Such systems shall include written certification
             1809      of the chemical additives at the time of original installation and service or maintenance."
             1810          [(20)] (22) IPC, Section 608.16.7, is deleted and replaced with the following: "608.16.7
             1811      Chemical dispensers. Where chemical dispensers connect to the water distribution system, the
             1812      water supply system shall be protected against backflow in accordance with Section 608.13.1,
             1813      Section 608.13.2, Section 608.13.5, Section 608.13.6 or Section 608.13.8. Chemical
             1814      dispensers shall connect to a separate dedicated water supply separate from any sink faucet."
             1815          [(21)] (23) IPC, Section 608.16.8, is deleted and replaced with the following: "608.16.8
             1816      Portable cleaning equipment. Where the portable cleaning equipment connects to the water
             1817      distribution system, the water supply system shall be protected against backflow in accordance
             1818      with Section 608.13.1, Section 608.13.2 or Section 608.13.8."
             1819          [(22)] (24) A new IPC, Section 608.16.11, is added as follows: "608.16.11 Automatic
             1820      and coin operated car washes. The water supply to an automatic or coin operated car wash
             1821      shall be protected in accordance with Section 608.13.1 or Section 608.13.2."
             1822          [(23)] (25) IPC, Section 608.17, is deleted[.] and replaced with the following: "608.17
             1823      Protection of individual water supplies. See Section 602.3 for requirements."


             1824          Section 21. Section 15A-3-307 is amended to read:
             1825           15A-3-307. Amendments to Chapter 7 of IPC.
             1826          (1) IPC, Section 701.2, is deleted and replaced with the following: "701.2 Sewer
             1827      required. Every building in which plumbing fixtures are installed and all premises having
             1828      drainage piping shall be connected to a public sewer where the sewer is accessible and is
             1829      within 300 feet of the property line in accordance with Utah Code, Section 10-8-38 ; or an
             1830      approved private sewage disposal system in accordance with Utah Administrative Code, Rule
             1831      R317-4, as administered by the Department of Environmental Quality, Division of Water
             1832      Quality."
             1833          (2) In IPC, Section 712.3.3.1, the following words are added before the word "or":
             1834      "stainless steel, cast iron, galvanized steel".
             1835          Section 22. Section 15A-3-308 is amended to read:
             1836           15A-3-308. Amendments to Chapter 8 of IPC.
             1837          [IPC, Chapter 8, is not amended.]
             1838          (1) In IPC, Section 802.1.8, the words "or directly connect" are added after the word
             1839      "break".
             1840          (2) In IPC, Section 802, a new Section 802.1.8.1 is added as follows: "802.1.8.1
             1841      Gravity grease interceptor connection: Those sinks or appliances draining into a gravity grease
             1842      interceptor shall discharge directly or indirectly through an air gap or air break into a floor
             1843      sink."
             1844          (3) In IPC, Section 802, a new Section 802.1.8.2 is added as follows: "802.1.8.2
             1845      Hydromechanical grease interceptor connection. Those sinks used for washing and primary
             1846      rinsing of utensils, dishes, pots, pans or service ware and draining through a hydromechanical
             1847      interceptor shall be directly connected to the interceptor. The sinks shall be trapped and vented
             1848      to prevent odors from the grease interceptor escaping through the sinks into the building. A
             1849      flow control device furnished by the manufacturer shall be installed on the inlet side of the
             1850      interceptor and in accordance with the manufacturers installation instructions. A floor sink
             1851      shall be installed within five (5') feet downstream of the interceptor outlet. A dedicated branch
             1852      drain shall be provided to serve the hydromechanical interceptor and the floor sink only. No
             1853      connections of any kind shall be permitted between the outlet of the interceptor and the
             1854      connection of the floor sink."


             1855          (4) In IPC, Section 802, a new Section 802.1.9 is added as follows: "802.1.9 Sanitizing
             1856      sinks. Sinks used for the sanitizing of utensils, dishes, pots, pans, or service ware shall
             1857      discharge indirectly through an air gap or air break to the drainage system."
             1858          Section 23. Section 15A-3-309 is amended to read:
             1859           15A-3-309. Amendments to Chapter 9 of IPC.
             1860          [(1) IPC, Section 901.3, is deleted and replaced with the following: "901.3 Chemical
             1861      waste vent system. The vent system for a chemical waste system shall be independent of the
             1862      sanitary vent system and shall terminate separately through the roof to the open air or to an air
             1863      admittance valve provided at least one chemical waste vent in the system terminates separately
             1864      through the roof to the open air."]
             1865          [(2)] (1) In IPC, Section [904.1] 903.1, when the number of inches is to be specified,
             1866      "12 inches (304.8mm)" is inserted.
             1867          [(3)] (2) In IPC, Section [904.6] 903.6, the following sentence is added at the end of
             1868      the paragraph: "Vents extending through the wall shall terminate not less than 12 inches from
             1869      the wall with an elbow pointing downward."
             1870          [(4)] (3) In IPC, Section 905.4, the following sentence is added at the end of the
             1871      paragraph: "Horizontal dry vents below the flood level rim shall be permitted for floor drain
             1872      [and], floor sink, and bath tub installations when installed in accordance with Sections 702.2,
             1873      905.2 and 905.3 and provided with a wall clean out."
             1874          [(5) In IPC, Section 917.8, a new exception is added as follows: "Exception: Air
             1875      admittance valves shall be permitted in non-neutralized special waste systems provided that
             1876      they conform to the requirements in Sections 901.3 and 702.5, are tested to ASTM F1412, and
             1877      are certified by ANSI/ASSE."]
             1878          Section 24. Section 15A-3-310 is amended to read:
             1879           15A-3-310. Amendments to Chapter 10 of IPC.
             1880          (1) In IPC, Section 1002.4, the following is added at the end of the paragraph:
             1881      "Approved Means of Maintaining Trap Seals. Approved means of maintaining trap seals
             1882      include the following, but are not limited to the methods cited:
             1883          (a) [Listed Trap Seal Primer] A listed trap seal primer conforming to ASSE 1018 and
             1884      ASSE 1044
             1885          (b) A hose bibb or bibbs within the same room


             1886          (c) Drainage from an untrapped lavatory discharging to the tailpiece of those fixture
             1887      traps which require priming. All fixtures shall be in the same room and on the same floor level
             1888      as the trap primer
             1889          (d) Barrier type floor drain trap seal protection device meeting ASSE Standard 1072
             1890          (e) Deep seal p-trap".
             1891          (2) In IPC, Section 1003.3.4, the following sentence is added before the last sentence:
             1892      "Hydrochemical grease interceptors and automatic grease removal devices shall not indirectly
             1893      discharge into a floor sink or any other indirect waste receptor, but shall directly connect to the
             1894      drainage system."
             1895          (3) IPC, Section 1003.3.4.2, is deleted and replaced with the following: "1003.3.4.2
             1896      Rate of flow controls. Hydromechanical grease interceptors shall be equipped with devices to
             1897      control the rate of water flow so that the water flow does not exceed the rated flow. The flow
             1898      control device shall be vented. The vent from the flow control device shall connect to the
             1899      plumbing vent system within the building or an approved and listed air admittance valve or
             1900      terminate out the roof. The flow control device shall be installed in accordance with the
             1901      manufacturers instructions."
             1902          Section 25. Section 15A-3-313 is amended to read:
             1903           15A-3-313. Amendments to Chapter 13 of IPC.
             1904          [IPC, Chapter 13, is not amended.]
             1905          (1) In IPC, Section 1301.1, all words after the word "urinals" are deleted and the
             1906      following sentence is added at the end: "Gray water recycling systems for subsurface landscape
             1907      irrigation shall conform with UAC R317-401 Gray Water Systems."
             1908          (2) A new IPC, Section 1301.1.1, is added as follows: "1301.1.1 Recording. The
             1909      existence of a gray water recycling system shall be recorded on the deed of ownership for that
             1910      property. The certificate of occupancy shall not be issued until the documentation of the
             1911      recording required under this section is completed by the owner."
             1912          (3) In IPC, Section 1301.2, the words "and systems for subsurface landscape irrigation
             1913      shall comply with Section 1303" are deleted.
             1914          (4) IPC, Section 1301.6, is deleted and replaced with the following: "1301.6 Potable
             1915      water connections. The potable water supply to any building utilizing a gray water recycling
             1916      system shall be protected against backflow by a reduced pressure backflow prevention


             1917      assembly installed in accordance with Section 608."
             1918          (5) In IPC, Section 1301.7, the following is added at the end of the sentence: "and other
             1919      clear water wastes which have a pH of 6.0 to 9.0; are non-flammable, non-combustible;
             1920      without objectionable odor; non-highly pigmented; and will not interfere with the operation of
             1921      the sewer treatment facility."
             1922          (6) In IPC, Section 1302.3, in the second sentence, the following is added between the
             1923      words "backflow" and "in": "by a reduced pressure backflow prevention assembly or an air gap
             1924      installed".
             1925          (7) IPC, Section 1303, is deleted and replaced with the following: "Section 1303
             1926      SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS. Gray water recycling systems
             1927      utilized for subsurface irrigation for single family residences shall comply with the
             1928      requirements of UAC R317-401, Gray Water Systems. Gray water recycling systems utilized
             1929      for subsurface irrigation for other occupancies shall comply with UAC R317-3, Design
             1930      Requirements for Wastewater Collection, Treatment and Disposal and UAC R317-4, Onsite
             1931      Waterwaste Systems."
             1932          Section 26. Section 15A-3-314 is amended to read:
             1933           15A-3-314. Amendments to Chapter 14 of IPC.
             1934          (1) In IPC, Chapter 14, the following referenced standard is added under ASSE:
             1935      "Standard
reference number
Title Referenced in code section
number
             1936      1072-2007 Performance Requirements for Barrier
Type Floor Drain Trap Seal Protection
Devices
1004.2"
             1937          (2) In IPC, Chapter 14, the following referenced standard is added:
             1938      "Standard
reference number
Title Referenced in code section
number
             1939      USC-FCCCHR
[9th] 10th Edition
Manual of Cross
Connection
Control
Foundation for Cross-Connection
Control and Hydraulic Research
University of Southern California
Kaprielian Hall 300 Los Angeles CA
90089-2531
Table 608.1"
             1940          [(3) IPC, Appendix C, is deleted and replaced with the following Appendix C, Gray
             1941      Water Recycling Systems, which may be adopted by local jurisdictions only as provided under
             1942      the State Construction Code: "Appendix C Gray Water Recycling Systems]
             1943      [Note: Section 301.3 of this code requires all plumbing fixtures that receive water or waste to
             1944      discharge to the sanitary drainage system of the structure. In order to allow for the utilization
             1945      of a gray water system, Section 301.3 should be revised to read as follows:]
             1946      [In jurisdictions which have adopted this Appendix C as amended as a local amendment as
             1947      provided herein, Section 301.3 of the IPC is deleted and replaced with the following:]
             1948      [301.3 Connections to drainage system. All plumbing fixtures, drains, appurtenances, and
             1949      appliances used to receive or discharge liquid wastes or sewage shall be directly connected to
             1950      the sanitary drainage system of the building or premises, in accordance with the requirements
             1951      of this code. This section shall not be construed to prevent indirect waste systems required by
             1952      Chapter 8.]
             1953      [Exception: Bathtubs, showers, lavatories, clothes washers, laundry trays, and approved clear
             1954      water wastes shall not be required to discharge to the sanitary drainage system where such
             1955      fixtures discharge to an approved gray water system for flushing of water closets and urinals or
             1956      for subsurface landscape irrigation.]
             1957      [SECTION C101 GENERAL]
             1958      [C101.1 Scope. The provisions of this appendix shall govern the materials, design,
             1959      construction, and installation of gray water systems for flushing of water closets and urinals
             1960      (see Figure 2).]
             1961      [C101.2 Recording. The existence of a gray water recycling system shall be recorded on the
             1962      deed of ownership for that property.]
             1963      [C101.3 Definition. The following term shall have the meaning shown herein.]
             1964      [GRAY WATER. Waste discharged from lavatories, bathtubs, showers, clothes washers,
             1965      laundry trays, and clear water wastes which have a pH of 6.0 to 9.0; are non-flammable;


             1966      non-combustible; without objectionable odors; non-highly pigmented; and will not interfere
             1967      with the operation of the sewer treatment facility.]
             1968      [C101.4 Permits. Permits shall be required in accordance with Section 106 and may also be
             1969      required by the local health department.]
             1970      [C101.5 Installation. In addition to the provisions of Section C101, systems for flushing of
             1971      water closets and urinals shall comply with Section C102. Except as provided for in Appendix
             1972      C, all systems shall comply with the provisions of the International Plumbing Code.]
             1973      [C101.6 Materials. Above-ground drain, waste, and vent piping for gray water systems shall
             1974      conform to one of the standards listed in Table 702.1. Gray water underground building
             1975      drainage and vent pipe shall conform to one of the standards listed in Table 702.2.]
             1976      [C101.7 Tests. Drain, waste, and vent piping for gray water systems shall be tested in
             1977      accordance with Section 312.]
             1978      [C101.8 Inspections. Gray water systems shall be inspected in accordance with Section 107.]
             1979      [C101.9 Potable water connections. The potable water supply to any building utilizing a gray
             1980      water recycling system shall be protected against backflow by a reduced pressure principle
             1981      backflow preventer installed in accordance with this Code.]
             1982      [C101.10 Waste water connections. Gray water recycling systems shall receive only the waste
             1983      discharge of bathtubs, showers, lavatories, clothes washers, or laundry trays, and other clear
             1984      water wastes which have a pH of 6.0 to 9.0; are non-flammable; non-combustible; without
             1985      objectionable odors; non-highly pigmented; and will not interfere with the operation of the
             1986      sewer treatment facility.]
             1987      [C101.11 Collection reservoir. Gray water shall be collected in an approved reservoir
             1988      constructed of durable, nonabsorbent, and corrosion-resistant materials. The reservoir shall be
             1989      a closed and gas-tight vessel. Access openings shall be provided to allow inspection and
             1990      cleaning of the reservoir interior.]
             1991      [C101.12 Filtration. Gray water entering the reservoir shall pass through an approved cartridge
             1992      filter having a design flow rate of less than 0.375 gallons per minute per square foot of
             1993      effective filter area, or a sand or diatomaceous earth filter designed to handle the anticipated
             1994      volume of water.]
             1995      [C101.12.1 Required valve. A full-open valve shall be installed downstream of the last fixture
             1996      connection to the gray water discharge pipe before entering the required filter.]


             1997      [C101.13 Overflow. The collection reservoir shall be equipped with an overflow pipe having
             1998      the same or larger diameter as the influent pipe for the gray water. The overflow pipe shall be
             1999      trapped and indirectly connected to the sanitary drainage system.]
             2000      [C101.14 Drain. A drain shall be located at the lowest point of the collection reservoir and
             2001      shall be indirectly connected to the sanitary drainage system. The drain shall be the same
             2002      diameter as the overflow pipe required in Section C101.12.]
             2003      [C101.15 Vent required. The reservoir shall be provided with a vent sized in accordance with
             2004      Chapter 9 and based on the diameter of the reservoir influent pipe.]
             2005      [SECTION C102 SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS]
             2006      [C102.1 Collection reservoir. The holding capacity of the reservoir shall be a minimum of
             2007      twice the volume of water required to meet the daily flushing requirements of the fixtures
             2008      supplied with gray water, but not less than 50 gallons (189 L). The reservoir shall be sized to
             2009      limit the retention time of gray water to a maximum of 72 hours.]
             2010      [C102.2 Disinfection. Gray water shall be disinfected by an approved method that employs
             2011      one or more disinfectants such as chlorine, iodine, or ozone that is recommended for use with
             2012      the pipes, fittings, and equipment by the manufacturer of the pipe, fittings, and equipment. A
             2013      minimum of 1ppm residual free chlorine shall be maintained in the gray water recycling system
             2014      reservoir.]
             2015      [C102.3 Makeup water. Potable water shall be supplied as a source of makeup water for the
             2016      gray water system. The potable water supply shall be protected against backflow by a reduced
             2017      pressure principle backflow preventer installed in accordance with this Code. There shall be a
             2018      full-open valve located on the makeup water supply line to the collection reservoir.]
             2019      [C102.4 Coloring. The gray water shall be dyed blue or green with a food grade vegetable dye
             2020      before such water is supplied to the fixtures.]
             2021      [C102.5 Materials. Distribution piping shall conform to one of the standards listed in Table
             2022      605.4.]
             2023      [C102.6 Identification. Distribution piping and reservoirs shall be identified as containing
             2024      nonpotable water. Piping identification shall be in accordance with Section 608.8.]
             2025      [SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS]
             2026      [C103.1 Gray water recycling systems utilized for subsurface irrigation for single family
             2027      residences shall comply with the requirements of Utah Administrative Code, R317-401, Gray


             2028      Water Systems. Gray water recycling systems utilized for subsurface irrigation for other
             2029      occupancies shall comply with Utah Administrative Code, R317-3 Design Requirements for
             2030      Wastewater Collection, Treatment and Disposal Systems, and Utah Administrative Code,
             2031      R317-4, Onsite Wastewater Systems."]
             2032          Section 27. Section 15A-3-401 is amended to read:
             2033     
Part 4. Statewide Amendments to IMC

             2034           15A-3-401. General provision.
             2035          The following are adopted as amendments to the IMC to be applicable statewide:
             2036          (1) In IMC, Section 202, the definition for "CONDITIONED SPACE" is deleted and
             2037      replaced with the following: "CONDITIONED SPACE. An area, room, or space enclosed
             2038      within the building thermal envelope that is directly heated or cooled, or indirectly heated or
             2039      cooled by any of the following means:
             2040      1. Openings directly into an adjacent conditioned space.
             2041      2. An un-insulated floor, ceiling or wall adjacent to a conditioned space.
             2042      3. Un-insulated duct, piping or other heat or cooling source within the space."
             2043          [(1)] (2) In IMC, Section 403, a new Section 403.8 is added as follows: "Retrospective
             2044      effect. Removal, alteration, or abandonment shall not be required, and continued use and
             2045      maintenance shall be allowed, for a ventilation system within an existing installation that
             2046      complies with the requirements of this Section 403 regardless of whether the ventilation system
             2047      satisfied the minimum ventilation rate requirements of prior law."
             2048          (3) In IMC, Table 603.4, in the section "Round ducts and enclosed rectangular ducts",
             2049      the word "enclosed" is deleted; the words "14 inches or less" are deleted and replaced with
             2050      "over 8 inches but less than 15 inches"; the wording "8 inches or less" under duct size, "0.013"
             2051      under minimum thickness (in.), "30" under equivalent gage no., and "0.0159" under aluminum
             2052      minimum thickness (in.), are added; and the section "Exposed rectangular ducts" is deleted.
             2053          (4) In IMC, Section 1004.2, the first sentence is deleted and replaced with the
             2054      following: "Boilers and pressure vessels in Utah are regulated by the Utah Labor Commission,
             2055      Division of Boiler, Elevator and Coal Mine Safety, except those located in private residences
             2056      or in apartment houses of less than five family units. Boilers shall be installed in accordance
             2057      with their listing and labeling, with minimum clearances as prescribed by the manufacture's
             2058      installation instructions."


             2059          (5) In IMC, Section 1004.3.1, the word "unlisted" is inserted before the word "boilers".
             2060          [(2)] (6) IMC, Section 1101.10, is deleted.
             2061          Section 28. Section 15A-3-501 is amended to read:
             2062     
Part 5. Statewide Amendments to IFGC

             2063           15A-3-501. General provision.
             2064          The following [is] are adopted as an amendment to the IFGC to be applicable
             2065      statewide[, in IFGC, Chapter 4, Section 401, General, a new section IFGC, Section 401.9, is]:
             2066          (1) In IFGC, Section 404.9, a new Section 404.9.1, is added as follows: "[401.9]
             2067      404.9.1 Meter protection. Fuel gas services shall be in an approved location and/or provided
             2068      with structures designed to protect the fuel gas meter and surrounding piping from physical
             2069      damage, including falling, moving, or migrating ice and snow. If an added structure is used, it
             2070      must still provide access for service and comply with the IBC or the IRC."
             2071          (2) IFGC, Section 409.5.3, is deleted.
             2072          (3) In IFGC, Section 631.2, the following sentence is inserted before the first sentence:
             2073      "Boilers and pressure vessels in Utah are regulated by the Utah Labor Commission, Division of
             2074      Boiler, Elevator and Coal Mine Safety, except those located in private residences or in
             2075      apartment houses of less than five family units."
             2076          Section 29. Section 15A-3-601 is amended to read:
             2077     
Part 6. Statewide Amendments to NEC

             2078           15A-3-601. General provision.
             2079          The following are adopted as amendments to the NEC to be applicable statewide:
             2080          (1) The IRC provisions are adopted as the residential electrical standards applicable to
             2081      installations applicable under the IRC. All other installations shall comply with the adopted
             2082      NEC.
             2083          (2) In NEC, Section 310.15(B)(7), the second sentence is deleted and replaced with the
             2084      following: "For application of this section, the main power feeder shall be the feeder(s)
             2085      between the main disconnect and the panelboard(s)."
             2086          Section 30. Section 15A-3-801 is amended to read:
             2087     
Part 8. Installation and Safety Requirements for Mobile Homes

             2088     
Built Before June 15, 1976

             2089           15A-3-801. General provision.


             2090          Mobile homes built before June 15, 1976 that are subject to relocation, building
             2091      alteration, remodeling, or rehabilitation shall comply with the following:
             2092          (1) Related to exits and egress windows:
             2093          (a) Egress windows. The home has at least one egress window in each bedroom, or a
             2094      window that meets the minimum specifications of the U.S. Department of Housing and Urban
             2095      Development's (HUD) Manufactured Homes Construction and Safety Standards (MHCSS)
             2096      program as set forth in 24 C.F.R. Parts 3280 and 3283, MHCSS 3280.106 and 3280.404 for
             2097      manufactured homes. These standards require the window to be at least 22 inches in the
             2098      horizontal or vertical position in its least dimension and at least five square feet in area. The
             2099      bottom of the window opening shall be no more than 36 inches above the floor, and the locks
             2100      and latches and any window screen or storm window devices that need to be operated to permit
             2101      exiting shall not be located more than 54 inches above the finished floor.
             2102          (b) Exits. The home is required to have two exterior exit doors, located remotely from
             2103      each other, as required in MHCSS 3280.105. This standard requires that single-section homes
             2104      have the doors no less than 12 feet, center-to-center, from each other, and multisection home
             2105      doors no less than 20 feet center-to-center from each other when measured in a straight line,
             2106      regardless of the length of the path of travel between the doors. One of the required exit doors
             2107      must be accessible from the doorway of each bedroom and no more than 35 feet away from any
             2108      bedroom doorway. An exterior swing door shall have a 28-inch-wide by 74-inch-high clear
             2109      opening and sliding glass doors shall have a 28-inch-wide by 72-inch-high clear opening. Each
             2110      exterior door other than screen/storm doors shall have a key-operated lock that has a passage
             2111      latch; locks shall not require the use of a key or special tool for operation from the inside of the
             2112      home.
             2113          (2) Related to flame spread:
             2114          (a) Walls, ceilings, and doors. Walls and ceilings adjacent to or enclosing a furnace or
             2115      water heater shall have an interior finish with a flame-spread rating not exceeding 25. Sealants
             2116      and other trim materials two inches or less in width used to finish adjacent surfaces within
             2117      these spaces are exempt from this provision, provided all joints are supported by framing
             2118      members or materials with a flame spread rating of 25 or less. Combustible doors providing
             2119      interior or exterior access to furnace and water heater spaces shall be covered with materials of
             2120      limited combustibility (i.e., 5/16-inch gypsum board, etc.), with the surface allowed to be


             2121      interrupted for louvers ventilating the space. However, the louvers shall not be of materials of
             2122      greater combustibility than the door itself (i.e., plastic louvers on a wooden door). Reference
             2123      MHCSS 3280.203.
             2124          (b) Exposed interior finishes. Exposed interior finishes adjacent to the cooking range
             2125      (surfaces include vertical surfaces between the range top and overhead cabinets, the ceiling, or
             2126      both) shall have a flame-spread rating not exceeding 50, as required by MHCSS 3280.203.
             2127      Backsplashes not exceeding six inches in height are exempted. Ranges shall have a vertical
             2128      clearance above the cooking top of not less than 24 inches to the bottom of combustible
             2129      cabinets, as required by MHCSS 3280.204(e).
             2130          (3) Related to smoke detectors:
             2131          (a) Location. A smoke detector shall be installed on any ceiling or wall in the hallway
             2132      or space communicating with each bedroom area between the living area and the first bedroom
             2133      door, unless a door separates the living area from that bedroom area, in which case the detector
             2134      shall be installed on the living-area side, as close to the door as practicable, as required by
             2135      MHCSS 3280.208. Homes with bedroom areas separated by anyone or combination of
             2136      common-use areas such as a kitchen, dining room, living room, or family room (but not a
             2137      bathroom or utility room) shall be required to have one detector for each bedroom area. When
             2138      located in the hallways, the detector shall be between the return air intake and the living areas.
             2139          (b) Switches and electrical connections. Smoke detectors shall have no switches in the
             2140      circuit to the detector between the over-current protection device protecting the branch circuit
             2141      and the detector. The detector shall be attached to an electrical outlet box and connected by a
             2142      permanent wiring method to a general electrical circuit. The detector shall not be placed on the
             2143      same branch circuit or any circuit protected by a ground-fault circuit interrupter.
             2144          (4) Related to solid-fuel-burning stoves/fireplaces:
             2145          (a) Solid-fuel-burning fireplaces and fireplace stoves. Solid-fuel-burning, factory-built
             2146      fireplaces, and fireplace stoves may be used in manufactured homes, provided that they are
             2147      listed for use in manufactured homes and installed according to their listing/manufacturer's
             2148      instructions and the minimum requirements of MHCSS 3280.709(g).
             2149          (b) Equipment. A solid-fuel-burning fireplace or fireplace stove shall be equipped with
             2150      an integral door or shutters designed to close the fire chamber opening and shall include
             2151      complete means for venting through the roof, a combustion air inlet, a hearth extension, and


             2152      means to securely attach the unit to the manufactured home structure.
             2153          (i) Chimney. A listed, factory-built chimney designed to be attached directly to the
             2154      fireplace/fireplace stove and equipped with, in accordance with the listing, a termination device
             2155      and spark arrester, shall be required. The chimney shall extend at least three feet above the part
             2156      of the roof through which it passes and at least two feet above the highest elevation of any part
             2157      of the manufactured home that is within 10 feet of the chimney.
             2158          (ii) Air-intake assembly and combustion-air inlet. An air-intake assembly shall be
             2159      installed in accordance with the terms of listings and the manufacturer's instruction. A
             2160      combustion-air inlet shall conduct the air directly into the fire chamber and shall be designed to
             2161      prevent material from the hearth from dropping on the area beneath the manufactured home.
             2162          (iii) Hearth. The hearth extension shall be of noncombustible material that is a
             2163      minimum of 3/8-inch thick and shall extend a minimum of 16 inches in front and eight inches
             2164      beyond each side of the fireplace/fireplace stove opening. The hearth shall also extend over the
             2165      entire surface beneath a fireplace stove and beneath an elevated and overhanging fireplace.
             2166          (5) Related to electrical wiring systems:
             2167          (a) Testing. All electrical systems shall be tested for continuity in accordance with
             2168      MHCSS 3280.810, to ensure that metallic parts are properly bonded; tested for operation, to
             2169      demonstrate that all equipment is connected and in working order; and given a polarity check,
             2170      to determine that connections are proper.
             2171          (b) 5.2 Protection. The electrical system shall be properly protected for the required
             2172      amperage load. If the unit wiring employs aluminum conductors, all receptacles and switches
             2173      rated at 20 amperes or less that are directly connected to the aluminum conductors shall be
             2174      marked CO/ALA. Exterior receptacles, other than heat tape receptacles, shall be of the
             2175      ground-fault circuit interrupter (GFI) type. Conductors of dissimilar metals (copper/aluminum
             2176      or copper-clad aluminum) must be connected in accordance with NEC, Section 110-14.
             2177          (6) Related to replacement furnaces and water heaters:
             2178          (a) Listing. Replacement furnaces or water heaters shall be listed for use in a
             2179      manufactured home. Vents, roof jacks, and chimneys necessary for the installation shall be
             2180      listed for use with the furnace or water heater.
             2181          (b) Securement and accessibility. The furnace and water heater shall be secured in
             2182      place to avoid displacement. Every furnace and water heater shall be accessible for servicing,


             2183      for replacement, or both as required by MHCSS 3280.709(a).
             2184          (c) Installation. Furnaces and water heaters shall be installed to provide complete
             2185      separation of the combustion system from the interior atmosphere of the manufactured home,
             2186      as required by MHCSS.
             2187          (i) Separation. The required separation may be achieved by the installation of a
             2188      direct-vent system (sealed combustion system) furnace or water heater or the installation of a
             2189      furnace and water heater venting and combustion systems from the interior atmosphere of the
             2190      home. There shall be no doors, grills, removable access panels, or other openings into the
             2191      enclosure from the inside of the manufactured home. All openings for ducts, piping, wiring,
             2192      etc., shall be sealed.
             2193          (ii) Water heater. The floor area in the area of the water heater shall be free from
             2194      damage from moisture to ensure that the floor will support the weight of the water heater.
             2195          Section 31. Repealer.
             2196          This bill repeals:
             2197          Section 15A-4-302, Amendments to IPC applicable to Salt Lake City.
             2198          Section 15A-4-304, Amendments to IPC applicable to Grand County.
             2199          Section 15A-4-305, Amendments to IPC applicable to City of Moab.
             2200          Section 15A-4-306, Amendments to IPC applicable to Murray City.
             2201          Section 15A-4-307, Amendments to IPC applicable to Salt Lake County.
             2202          Section 32. Effective date.
             2203          This bill takes effect on July 1, 2013.




Legislative Review Note
    as of 2-7-13 12:59 PM