House of Representatives
State of Utah
Madam Speaker:
The Business and Labor Committee reports a favorable recommendation on H.B. 310,
CONSTRUCTION CODE AMENDMENTS, by Representative B. Wilson, with the following
amendments:
41
15A-3-307, as enacted by Laws of Utah 2011, Chapter 14
1835
Sanitizing
1891
James A. Dunnigan
1. Page
2, Lines 44 through 46
:
44
15A-3-310, as enacted by Laws of Utah 2011, Chapter 14
45
15A-3-313, as enacted by Laws of Utah 2011, Chapter 14
46
15A-3-314, as enacted by Laws of Utah 2011, Chapter 14
2. Page
17, Lines 518 through 520
:
518
[(11)] (8) IBC, [Subsections] Sections (F)904.11.3, (F)904.11.3.1, (F)904.11.4, and
519
(F)904.11.4.1, are deleted.
(a) The first sentence is deleted and rewritten as follows: "A manual fire alarm
system that initiates the occupant notification system in accordance with Section (F)
907.5 and installed in accordance with Section (F) 907.6 shall be installed in Group
E occupancies."
(b) In Exception number 3, starting on line five, the words "emergency
voice/alarm communication system" are deleted and replaced with "occupant
notification system".
520
[(12) A new IBC, Section (F)907.9, is added as follows: "Section (F)907.9 Carbon
3. Page
18, Lines 529 through 531
:
529
(9) In IBC, Section (F)908.7,
530
added after the first sentence: "A minimum of one carbon monoxide alarm shall be
installed on
531
each habitable level."
4. Page
32, Lines 928 through 932
:
928
Section 11.
Section
15A-3-113
is amended to read:
929
15A-3-113. Amendments to Chapters 32 through 35 of IBC.
930
(1) A new section IBC, Section
3401.6
}
3401.7
, is added as follows:
"
{
3401.6
}
3401.7
Parapet bracing,
931
wall anchors, and other appendages. Until June 30, 2014, a building constructed before
1975
932
shall have parapet bracing, wall anchors, and appendages such as cornices, spires, towers,
5. Page
74, Lines 1740 through 1742
:
1740
[(8)] (10) In IPC, Section 608.6, the following sentence is added at the end of the
1741
paragraph: "Any connection between potable water piping and sewer-connected waste
shall be
1742
protected by an air gap in accordance with Section
308.13.1
}
608.13.1
."
6. Page
79, Lines 1900 through 1901
:
1900
terminate out the roof. The flow control device shall be installed in accordance with the
1901
manufacturers instructions."
15A-3-311
.
Amendments to Chapter 11 of IPC.
(1) IPC, Section 1104.2, is deleted and replaced with the following: "1104.2
Combining storm and sanitary drainage prohibited. The combining of sanitary and storm
drainage systems is prohibited."
(2) IPC, Section
1108
}
1109
, is deleted.
7. Page 2, Lines 41 through 43:
42
15A-3-308, as enacted by Laws of Utah 2011, Chapter 14
}
43
15A-3-309, as enacted by Laws of Utah 2011, Chapter 14
8. Page 77, Line 1835 through Page 78 Line 1057
Section 22.
Section
15A-3-308
is amended to read:
1836
15A-3-308. Amendments to Chapter 8 of IPC.
1837
[IPC, Chapter 8, is not amended.]
1838
(1) In IPC, Section 802.1.8, the words "or directly connect" are added after the
word
1839
"break".
1840
(2) In IPC, Section 802, a new Section 802.1.8.1 is added as follows: "802.1.8.1
1841
Gravity grease interceptor connection: Those sinks or appliances draining into a
gravity grease
1842
interceptor shall discharge directly or indirectly through an air gap or air break into
a floor
1843
sink."
1844
(3) In IPC, Section 802, a new Section 802.1.8.2 is added as follows: "802.1.8.2
1845
Hydromechanical grease interceptor connection. Those sinks used for washing and
primary
1846
rinsing of utensils, dishes, pots, pans or service ware and draining through a
hydromechanical
1847
interceptor shall be directly connected to the interceptor. The sinks shall be trapped
and vented
1848
to prevent odors from the grease interceptor escaping through the sinks into the
building. A
1849
flow control device furnished by the manufacturer shall be installed on the inlet side
of the
1850
interceptor and in accordance with the manufacturers installation instructions. A
floor sink
1851
shall be installed within five (5') feet downstream of the interceptor outlet. A
dedicated branch
1852
drain shall be provided to serve the hydromechanical interceptor and the floor sink
only. No
1853
connections of any kind shall be permitted between the outlet of the interceptor and
the
1854
connection of the floor sink."
1855
(4) In IPC, Section 802, a new Section 802.1.9 is added as follows: "802.1.9
1856
sinks. Sinks used for the sanitizing of utensils, dishes, pots, pans, or service ware
shall
1857
discharge indirectly through an air gap or air break to the drainage system."
}
9. Page 9, Lines 1891 through 1901:
(2) In IPC, Section 1003.3.4, the following sentence is added before the last
sentence:
1892
"Hydrochemical grease interceptors and automatic grease removal devices shall not
indirectly
1893
discharge into a floor sink or any other indirect waste receptor, but shall directly
connect to the
1894
drainage system."
1895
(3) IPC, Section 1003.3.4.2, is deleted and replaced with the following:
"1003.3.4.2
1896
Rate of flow controls. Hydromechanical grease interceptors shall be equipped with
devices to
1897
control the rate of water flow so that the water flow does not exceed the rated flow.
The flow
1898
control device shall be vented. The vent from the flow control device shall connect
to the
1899
plumbing vent system within the building or an approved and listed air admittance
valve or
1900
terminate out the roof. The flow control device shall be installed in accordance with
the
1901
manufacturers instructions."
}
Renumber remaining sections accordingly.
Respectfully,
Committee Chair
Voting: 13-0-3
3 HB0310.HC1.wpd 2/21/13 9:54 am bhowe/BRH CRG/BRH
Bill Number
*HB0310*
HB0310