UNIFORM CONSTRUCTION CODE AMENDMENTS

2     
2018 GENERAL SESSION

3     
STATE OF UTAH

4     
Chief Sponsor: Mike Schultz

5     
Senate Sponsor: Curtis S. Bramble

6     

7     LONG TITLE
8     Committee Note:
9          The Business and Labor Interim Committee recommended this bill.
10     General Description:
11          This bill amends the State Construction and Fire Codes Act.
12     Highlighted Provisions:
13          This bill:
14          ▸     adds the definition of an "injection well" to the International Plumbing Code;
15          ▸     adds a section regarding the prohibition of motor vehicle waste disposal wells to the
16     International Plumbing Code;
17          ▸     amends the International Residential Code;
18          ▸     incorporates by reference the 2017 edition of the National Electrical Code;
19          ▸     amends incorporated provisions of the National Electrical Code; and
20          ▸     makes technical changes.
21     Money Appropriated in this Bill:
22          None
23     Other Special Clauses:
24          None
25     Utah Code Sections Affected:
26     AMENDS:
27          15A-2-103, as last amended by Laws of Utah 2016, Chapter 249

28          15A-3-206, as last amended by Laws of Utah 2017, Chapter 236
29          15A-3-302, as last amended by Laws of Utah 2016, Chapter 249
30          15A-3-304, as last amended by Laws of Utah 2016, Chapter 249
31          15A-3-601, as last amended by Laws of Utah 2016, Chapter 249
32     

33     Be it enacted by the Legislature of the state of Utah:
34          Section 1. Section 15A-2-103 is amended to read:
35          15A-2-103. Specific editions adopted of construction code of a nationally
36     recognized code authority.
37          (1) Subject to the other provisions of this part, the following construction codes are
38     incorporated by reference, and together with the amendments specified in Chapter 3, Part 3,
39     Statewide Amendments to International Plumbing Code, and Chapter 4, Local Amendments
40     Incorporated as Part of State Construction Code, are the construction standards to be applied to
41     building construction, alteration, remodeling, and repair, and in the regulation of building
42     construction, alteration, remodeling, and repair in the state:
43          (a) the 2015 edition of the International Building Code, including Appendix J, issued
44     by the International Code Council;
45          (b) the 2015 edition of the International Residential Code, issued by the International
46     Code Council;
47          (c) the 2015 edition of the International Plumbing Code, issued by the International
48     Code Council;
49          (d) the 2015 edition of the International Mechanical Code, issued by the International
50     Code Council;
51          (e) the 2015 edition of the International Fuel Gas Code, issued by the International
52     Code Council;
53          (f) the [2014] 2017 edition of the National Electrical Code, issued by the National Fire
54     Protection Association;
55          (g) the 2015 edition of the International Energy Conservation Code, issued by the
56     International Code Council;
57          (h) the 2015 edition of the International Existing Building Code, issued by the
58     International Code Council;

59          (i) subject to Subsection 15A-2-104(2), the HUD Code;
60          (j) subject to Subsection 15A-2-104(1), Appendix E of the 2015 edition of the
61     International Residential Code, issued by the International Code Council; and
62          (k) subject to Subsection 15A-2-104(1), the 2005 edition of the NFPA 225 Model
63     Manufactured Home Installation Standard, issued by the National Fire Protection Association.
64          (2) Consistent with Title 65A, Chapter 8, Management of Forest Lands and Fire
65     Control, the Legislature adopts the 2006 edition of the Utah Wildland Urban Interface Code,
66     issued by the International Code Council, with the alternatives or amendments approved by the
67     Utah Division of Forestry, as a construction code that may be adopted by a local compliance
68     agency by local ordinance or other similar action as a local amendment to the codes listed in
69     this section.
70          Section 2. Section 15A-3-206 is amended to read:
71          15A-3-206. Amendments to Chapters 39 and 44 and Appendix F of IRC.
72          (1) In IRC, Section E3705.4.5, the following words are added after the word
73     "assemblies": "with ungrounded conductors 10 AWG and smaller".
74          [(1)] (2) In IRC, Section E3901.9, the following exception is added:
75     "Exception: Receptacles or other outlets adjacent to the exterior walls of the garage, outlets
76     adjacent to an exterior wall of the garage, or outlets in a storage room with entry from the
77     garage may be connected to the garage branch circuit."
78          [(2)] (3) IRC, Section E3902.16 is deleted.
79          [(3)] (4) In Section E3902.17:
80          (a) following the word "Exception" the number "1." is added; and
81          (b) at the end of the section, the following sentences are added:
82     "2. This section does not apply for a simple move or an extension of a branch circuit or an
83     outlet which does not significantly increase the existing electrical load. This exception does
84     not include changes involving remodeling or additions to a residence."
85          [(4)] (5) IRC, Chapter 44, is amended by adding the following reference standard:
86      "Standard reference
number
TitleReferenced in code
section number
87      USC-FCCCHR 10th
Edition Manual of
Cross Connection
Control
Foundation for Cross-Connection Control
and Hydraulic Research University of
Southern California Kaprielian Hall 300
Los Angeles CA 90089-2531
Table P2902.3"
88          [(5)] (6) (a) When passive radon controls or portions thereof are voluntarily installed,
89     the voluntary installation shall comply with Appendix F of the IRC.
90          (b) An additional inspection of a voluntary installation described in Subsection [(5)]
91     (6)(a) is not required.
92          Section 3. Section 15A-3-302 is amended to read:
93          15A-3-302. Amendments to Chapters 1 and 2 of IPC.
94          (1) A new IPC, Section 101.2.1, is added as follows: "For clarification, the
95     International Private Sewage Disposal Code is not part of the plumbing code even though it is
96     in the same printed volume."
97          (2) In IPC, Section 202, the definition for "Backflow Backpressure, Low Head" is
98     deleted.
99          (3) In IPC, Section 202, the following definition is added: "Certified Backflow
100     Preventer Assembly Tester. A person who has shown competence to test Backflow prevention
101     assemblies to the satisfaction of the authority having jurisdiction under Utah Code, Subsection
102     19-4-104(4)."
103          (4) In IPC, Section 202, the following definition is added: "Contamination (High
104     Hazard). An impairment of the quality of the potable water that creates an actual hazard to the
105     public health through poisoning or through the spread of disease by sewage, industrial fluids or
106     waste."
107          (5) In IPC, Section 202, the definition for "Cross Connection" is deleted and replaced
108     with the following: "Cross Connection. Any physical connection or potential connection or
109     arrangement between two otherwise separate piping systems, one of which contains potable
110     water and the other either water of unknown or questionable safety or steam, gas, or chemical,
111     whereby there exists the possibility for flow from one system to the other, with the direction of
112     flow depending on the pressure differential between the two systems (see "Backflow")."
113          (6) In IPC, Section 202, the following definition is added: "Deep Seal Trap. A
114     manufactured or field fabricated trap with a liquid seal of 4" or larger."

115          (7) In IPC, Section 202, the definition for "Essentially Nontoxic Transfer Fluid" is
116     deleted and replaced with the following:
117     "ESSENTIALLY NONTOXIC TRANSFER FLUID. Fluids having a Gosselin rating of 1,
118     including propylene glycol; and mineral oil."
119          (8) In IPC, Section 202, the definition for "Essentially Toxic Transfer Fluid" is deleted
120     and replaced with the following:
121     "ESSENTIALLY TOXIC TRANSFER FLUID. Soil, waste, or gray water; and any fluid that is
122     not an essentially nontoxic transfer fluid under this code."
123          (9) In IPC, Section 202, the following definition is added: "High Hazard. See
124     Contamination."
125          (10) In IPC, Section 202, the following definition is added: "Injection well. A bored,
126     drilled, or driven shaft whose depth is greater than the largest surface dimension; or a dug hole
127     whose depth is greater than the largest surface dimension; or an improved sinkhole; or a
128     subsurface fluid distribution system the primary purpose for which is the subsurface
129     emplacement of fluids. An injection well is subject to any Water Quality Board rule made
130     under Section 19-5-104 regarding underground injection. An injection well associated with a
131     single family residence is not subject to any Water Quality Board rule made under Section
132     19-5-104 regarding underground injection."
133          [(10)] (11) In IPC, Section 202, the following definition is added: "Low Hazard. See
134     Pollution."
135          [(11)] (12) In IPC, Section 202, the following definition is added: "Pollution (Low
136     Hazard). An impairment of the quality of the potable water to a degree that does not create a
137     hazard to the public health but that does adversely and unreasonably affect the aesthetic
138     qualities of such potable water for domestic use."
139          [(12)] (13) In IPC, Section 202, the definition for "Potable Water" is deleted and
140     replaced with the following: "Potable Water. Water free from impurities present in amounts
141     sufficient to cause disease or harmful physiological effects and conforming to the Utah Code,
142     Title 19, Chapter 4, Safe Drinking Water Act, and Title 19, Chapter 5, Water Quality Act, and
143     the regulations of the public health authority having jurisdiction."
144          Section 4. Section 15A-3-304 is amended to read:
145          15A-3-304. Amendments to Chapter 4 of IPC.

146          (1) In IPC, Table 403.1, the following changes are made:
147          (a) The title for Table 403.1 is deleted and replaced with the following: "Table 403.1,
148     Minimum Number of Required Plumbing Fixturesa, h";
149          (b) In row number "3", for "E" occupancy, in the field for "OTHER", a new footnote g
150     is added.
151          (c) In row number "5", for "I-4 Adult day care and child day care" occupancy, in the
152     field for "OTHER", a new footnote g is added.
153          (d) A new footnote f is added as follows: "FOOTNOTE: f. When provided, in public
154     toilet facilities, there shall be an equal number of diaper changing facilities in male toilet rooms
155     and female toilet rooms. Diaper changing facilities shall meet the requirements of ASTM
156     F2285-04 (2010) Standard Consumer Safety Performance Specifications for Diaper Changing
157     Tables for Commercial Use."
158          (e) A new footnote g is added to the table as follows: "FOOTNOTE g: Non-residential
159     child care facilities shall comply with the additional requirements for sinks in administrative
160     rule made by the Department of Health."
161          (2) A new IPC, Section 406.3, is added as follows: " 406.3 Automatic clothes washer
162     safe pans. Safe pans, when installed under automatic clothes washers, shall be installed in
163     accordance with Section 504.7."
164          (3) A new IPC, Section 412.5, is added as follows: "412.5 Public toilet rooms. All
165     public toilet rooms in A & E occupancies and M occupancies with restrooms having multiple
166     water closets or urinals shall be equipped with at least one floor drain."
167          (4) A new IPC, Section 412.6, is added as follows: "412.6 Prohibition of Motor
168     Vehicle Waste Disposal Wells. Injection wells, including floor drains, septic systems, French
169     drains, dry wells, etc., that discharge to the subsurface are prohibited if vehicular service or
170     maintenance activities involving vehicular fluids and associated fluids occur within the
171     catchment area of the injection well."
172          [(4)] (5) IPC, Section 423.3, is deleted.
173          Section 5. Section 15A-3-601 is amended to read:
174          15A-3-601. General provisions.
175          The following are adopted as amendments to the NEC to be applicable statewide:
176          (1) The IRC provisions are adopted as the residential electrical standards applicable to

177     residential installations [applicable] under the IRC. All other installations shall comply with
178     the adopted NEC.
179          [(2) NEC, Section 240.87(B), is modified to add the following as an additional
180     approved equivalent means:]
181     ["6. An instantaneous trip function set at or below the available fault current."]
182          (2) In NEC, Section 210.8(B), the words "and three phase receptacles rated 150 volts to
183     ground or less, 100 amperes or less" are deleted.
184          (3) NEC, Section 210.71, is deleted.
185          (4) In NEC, Section 240.67, the words "January 1, 2020" are deleted and replaced with
186     "upon adoption of the 2020 NEC".






Legislative Review Note
Office of Legislative Research and General Counsel