First Substitute H.B. 305
1
2
3
4
5
6
7 LONG TITLE
8 General Description:
9 This bill modifies a provision amending the state construction code.
10 Highlighted Provisions:
11 This bill:
12 . modifies a provision requiring an engineer evaluation of certain buildings built
13 before 1975;
14 . temporarily eliminates a requirement that the evaluation occur when the building is
15 undergoing reroofing or an alteration of or repair to certain features; and
16 . replaces that requirement with a temporary requirement that the evaluation occur
17 when the building is undergoing structural alterations or repairs, and specifies what
18 is not included in structural alterations or repairs.
19 Money Appropriated in this Bill:
20 None
21 Other Special Clauses:
22 None
23 Utah Code Sections Affected:
24 AMENDS:
25 15A-3-113, as enacted by Laws of Utah 2011, Chapter 14
26
27 Be it enacted by the Legislature of the state of Utah:
28 Section 1. Section 15A-3-113 is amended to read:
29 15A-3-113. Amendments to Chapters 32 through 35 of IBC.
30 (1) A new section IBC, Section 3401.6, is added as follows: "3401.6 Parapet bracing,
31 wall anchors, and other appendages. [
32 before 1975 shall have parapet bracing, wall anchors, and appendages such as cornices, spires,
33 towers, tanks, signs, statuary, etc. evaluated by a licensed engineer when [
34 undergoing [
35 alterations, which may include structural sheathing replacement of 10% or greater, or other
36 structural repairs. Reroofing or water membrane replacement may not be considered a
37 structural alteration or repair for purposes of this section. Beginning July 1, 2014, a building
38 constructed before 1975 shall have parapet bracing, wall anchors, and appendages such as
39 cornices, spires, towers, tanks, signs, statuary, etc. evaluated by a licensed engineer when the
40 building is undergoing a total reroofing. Parapet bracing, wall anchors, and appendages
41 required by this section shall be evaluated in accordance with 75% of the seismic forces as
42 specified in Section 1613. When allowed by the local building official, alternate methods of
43 equivalent strength as referenced in an approved code under Utah Code, Subsection
44 15A-1-204 (6)(a), will be considered when accompanied by engineer-sealed drawings, details,
45 and calculations. When found to be deficient because of design or deteriorated condition, the
46 engineer's recommendations to anchor, brace, reinforce, or remove the deficient feature shall be
47 implemented.
48 Exceptions:
49 1. Group R-3 and U occupancies.
50 2. Unreinforced masonry parapets need not be braced according to the above stated provisions
51 provided that the maximum height of an unreinforced masonry parapet above the level of the
52 diaphragm tension anchors or above the parapet braces shall not exceed one and one-half times
53 the thickness of the parapet wall. The parapet height may be a maximum of two and one-half
54 times its thickness in other than Seismic Design Categories D, E, or F."
55 (2) IBC, Section 3408.4, is deleted and replaced with the following: "3408.4 Change in
56 Occupancy. When a change in occupancy results in a structure being reclassified to a higher
57 Occupancy Category (as defined in Table 1604.5), or when such change of occupancy results in
58 a design occupant load increase of 100% or more, the structure shall conform to the seismic
59 requirements for a new structure.
60 Exceptions:
61 1. Specific seismic detailing requirements of this code or ASCE 7 for a new structure shall not
62 be required to be met where it can be shown that the level of performance and seismic safety is
63 equivalent to that of a new structure. Such analysis shall consider the regularity, overstrength,
64 redundancy, and ductility of the structure within the context of the existing and retrofit (if any)
65 detailing providing. Alternatively, the building official may allow the structure to be upgraded
66 in accordance with referenced sections as found in an approved code under Utah Code,
67 Subsection 15A-1-204 (6)(a).
68 2. When a change of use results in a structure being reclassified from Occupancy Category I or
69 II to Occupancy Category III and the structure is located in a seismic map area where SDS is
70 less than 0.33, compliance with the seismic requirements of this code and ASCE 7 are not
71 required.
72 3. Where design occupant load increase is less than 25 occupants and the Occupancy Category
73 does not change."
74 (3) In IBC, Section 3411.1, the exception is deleted and replaced with the following:
75 "Exception: Type B dwelling or sleeping units required by Section 1107 of this code are not
76 required to be provided in existing buildings and facilities unless being altered or undergoing a
77 change of occupancy classification."
78 (4) The following referenced standard is added under NFPA in IBC, Chapter 35:
79 | "Number | Title | Referenced in code section number |
80 | 720-09 |
Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment |
907.9" |
82 | "Number | Title | Referenced in code section number |
83 | 2034-2008 |
Standard of Single- and Multiple-station Carbon Monoxide Alarms |
907.9" |
85 the following:
86 | "Number | Title | Referenced in code section number |
87 | 10-10 | Portable Fire Extinguishers |
906.2, 906.3.2, 906.3.4, Table 906.3(1), Table 906.3(2)" |
89 the following:
90 | "Number | Title | Referenced in code section number |
91 | 11-10 | Low Expansion Foam | 904.7" |
93 the following:
94 | "Number | Title | Referenced in code section number |
95 | 12-08 |
Carbon Dioxide Extinguishing Systems |
904.8, 904.11" |
97 the following:
98 | "Number | Title | Referenced in code section number |
99 | 12A-09 |
Halon 1301 Fire Extinguishing Systems |
904.9" |
101 the following:
102 | "Number | Title | Referenced in code section number |
103 | 13-10 | Installation of Sprinkler Systems |
708.2, 903.3.1.1, 903.3.2, 903.3.5.1.1, 903.3.5.3, 904.11, 905.3.4, 907.6.3, 1613.3" |
105 with the following:
106 | "Number | Title | Referenced in code section number |
107 | 13D-10 |
Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes |
903.3.1.3, 903.3.5.1.1" |
109 with the following:
110 | "Number | Title | Referenced in code section number |
111 | 13R-10 |
Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height |
903.3.1.2, 903.3.5.1.1, 903.3.5.1.2, 903.4" |
113 the following:
114 | "Number | Title | Referenced in code section number |
115 | 14-10 |
Installation of Standpipe and Hose System |
905.2, 905.3.4, 905.6.2, 905.8" |
117 the following:
118 | "Number | Title | Referenced in code section number |
119 | 17-09 | Dry chemical Extinguishing Systems | 904.5, 904.11" |
121 with the following:
122 | "Number | Title | Referenced in code section number |
123 | 17A-09 | Wet Chemical Extinguishing System | 904.5, 904.11" |
125 the following:
126 | "Number | Title | Referenced in code section number |
127 | 20-10 |
Installation of Stationary Pumps for Fire Protection |
913.1, 913.2.1, 913.5" |
129 the following:
130 | "Number | Title | Referenced in code section number |
131 | 72-10 | National Fire Alarm Code |
901.6, 903.4.1, 904.3.5, 907.2, 907.2.5, 907.2.11, 907.2.13.2, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.3.3, 907.6, 907.6.1, 907.6.5, 907.7, 907.7.1, 907.7.2, 911.1.5, 3006.5, 3007.6" |
133 with the following:
134 | "Number | Title | Referenced in code section number |
135 | 92B-09 |
Smoke Management Systems in Malls, Atria and Large Spaces |
909.8" |
137 with the following:
138 | "Number | Title | Referenced in code section number |
139 | 101-09 | Line Safety Code | 1028.6.2" |
141 with the following:
142 | "Number | Title | Referenced in code section number |
143 | 110-10 |
Emergency and Standby Power Systems |
2702.1" |