H.B. 202 Enrolled

             1     

ENERGY CONSERVATION CODE AMENDMENTS

             2     
2013 GENERAL SESSION

             3     
STATE OF UTAH

             4     
Chief Sponsor: Brad R. Wilson

             5     
Senate Sponsor: Curtis S. Bramble

             6     
             7      LONG TITLE
             8      General Description:
             9          This bill amends the State Construction Code.
             10      Highlighted Provisions:
             11          This bill:
             12          .    adopts the 2012 edition of the International Energy Conservation Code;
             13          .    modifies certain provisions of the International Energy Conservation Code; and
             14          .    modifies certain energy provisions of the International Residential Code.
             15      Money Appropriated in this Bill:
             16          None
             17      Other Special Clauses:
             18          This bill provides a contingent effective date.
             19      Utah Code Sections Affected:
             20      AMENDS:
             21          15A-2-103, as last amended by Laws of Utah 2012, Chapter 76
             22          15A-3-203, as enacted by Laws of Utah 2011, Chapter 14
             23          15A-3-701, as enacted by Laws of Utah 2011, Chapter 14
             24      Uncodified Material Affected:
             25      ENACTS UNCODIFIED MATERIAL
             26     
             27      Be it enacted by the Legislature of the state of Utah:
             28          Section 1. Section 15A-2-103 is amended to read:
             29           15A-2-103. Specific editions adopted of construction code of a nationally


             30      recognized code authority.
             31          (1) Subject to the other provisions of this part, the following construction codes are
             32      incorporated by reference, and together with the amendments specified in Chapter 3, Statewide
             33      Amendments to International Plumbing Code, and Chapter 4, Local Amendments Incorporated
             34      as Part of State Construction Code, are the construction standards to be applied to building
             35      construction, alteration, remodeling, and repair, and in the regulation of building construction,
             36      alteration, remodeling, and repair in the state:
             37          (a) the 2009 edition of the International Building Code, including Appendix J, issued
             38      by the International Code Council;
             39          (b) the 2009 edition of the International Residential Code, issued by the International
             40      Code Council;
             41          (c) the 2009 edition of the International Plumbing Code, issued by the International
             42      Code Council;
             43          (d) the 2009 edition of the International Mechanical Code, issued by the International
             44      Code Council;
             45          (e) the 2009 edition of the International Fuel Gas Code, issued by the International
             46      Code Council;
             47          (f) the 2011 edition of the National Electrical Code, issued by the National Fire
             48      Protection Association;
             49          (g) the [2009] 2012 edition of the International Energy Conservation Code, issued by
             50      the International Code Council;
             51          (h) subject to Subsection 15A-2-104 (2), the HUD Code;
             52          (i) subject to Subsection 15A-2-104 (1), Appendix E of the 2009 edition of the
             53      International Residential Code, issued by the International Code Council; and
             54          (j) subject to Subsection 15A-2-104 (1), the 2005 edition of the NFPA 225 Model
             55      Manufactured Home Installation Standard, issued by the National Fire Protection Association.
             56          (2) Consistent with Title 65A, Chapter 8, Management of Forest Lands and Fire
             57      Control, the Legislature adopts the 2006 edition of the Utah Wildland Urban Interface Code,


             58      issued by the International Code Council, with the alternatives or amendments approved by the
             59      Utah Division of Forestry, as a construction code that may be adopted by a local compliance
             60      agency by local ordinance or other similar action as a local amendment to the codes listed in
             61      this section.
             62          Section 2. Section 15A-3-203 is amended to read:
             63           15A-3-203. Amendments to Chapters 6 through 15 of IRC.
             64          [(1) IRC, Sections R612.2 through R612.4.2, are deleted.]
             65          [(2) IRC, Chapter 11, is deleted and replaced with Chapter 11 of the 2006 International
             66      Residential Code and Chapter 4 of the 2006 International Energy Conservation Code.]
             67          (1) In IRC, Section N1101.8 (R103.2), all words after the words "herein governed." are
             68      deleted and replaced with the following: "Construction documents include all documentation
             69      required to be submitted in order to issue a building permit."
             70          (2) In IRC, Section N1101.14 (R303.3), all wording after the first sentence is deleted.
             71          (3) In IRC, Table N1102.1.1 (R402.1.1) and Table N1102.1.3 (R402.1.3), the rows for
             72      "climate zone 3", "climate zone 5 and Marine 4", and "climate zone 6" are deleted and replaced
             73      and a new footnote j is added as follows:
             74      "TABLE N1102.1.1 (R402.1.1)
             75      INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
             76     

CLIMATE
ZONE


FENESTRATION
U-FACTOR b


SKYLIGHT b
U-FACTOR

GLAZED
FENESTRATION
SHGC b,e


CEILING
R-VALUE

WOOD
FRAME WALL
R-VALUE

MASS
WALL
R-VALUE i,j


FLOOR
R-VALUE

BASEMENT c
WALL
R-VALUE

SLAB d
R-VALUE
& DEPTH
CRAWL
SPACE c
WALL
R-VALUE
             77      3 0.65 0.65 0.40 30 15 5 19 0 0 5/13
             78      5 and
Marine 4
0.35 0.60 NR 38 19 or 13 +
5h
13 30 g 10/13 10, 2 ft 10/13
             79      6 0.35 0.60 NR 49 19 or 13 +
5h
15 30 g 10/13 10, 4 ft 10/13
             80      j. Log walls complying with ICC400 and with a minimum average wall thickness of 5” or greater shall be permitted in Zones
5-8 when overall window glazing is .31 U-factor or lower, minimum heating equipment efficiency is 90 AFUE (gas) or 84
AFUE (oil), and all other component requirements are met.”


             81      TABLE N1102.1.3 (R402.1.3)
             82      EQUIVALENT U-FACTORSa
             83     

CLIMATE

ZONE


FENESTRATION
U-FACTOR


SKYLIGHT
U-FACTOR


CEILING
U-FACTOR

FRAME
WALL
U-FACTOR


MASS WALL
U-FACTOR b


FLOOR
U-FACTOR

BASEMENT
WALL
U-FACTOR
CRAWL
SPACE
WALL

U-FACTOR
             84      3 0.65 0.65 0.035 0.082 0.141 0.047 0.360 0.136
             85      5 and
Marine 4
0.35 0.60 0.030 0.060 0.082 0.033 0.059 0.065
             86      6 0.35 0.60 0.026 0.060 0.060 0.033 0.059 0.065
             87          (4) In IRC, Section N1102.2.1 (R402.2.1), the last sentence is deleted.
             88          (5) In IRC, Section N1102.2.2 (R402.2.2), the last sentence is deleted.
             89          (6) In IRC, Section N1102.3.3 (R402.3.3), the last sentence is deleted.
             90          (7) In IRC, Section N1102.3.4 (R402.3.4), the last sentence is deleted.
             91          (8) In IRC, Section N1102.4.1 (R402.4.1), in the first sentence, the word "and" is
             92      deleted and replaced with the word "or".
             93          (9) In IRC, Section N1102.4.1.1 (R402.4.1.1), the last sentence is deleted and replaced
             94      with the following: "Where allowed by the building official, the builder may certify compliance
             95      to components criteria for items which may not be inspected during regularly scheduled
             96      inspections."
             97          (10) In IRC, Section N1102.4.1.2 (R402.4.1.2), the following changes are made:
             98          (a) In the first sentence, the words "in Zones 1 and 2, and 3 air changes per hour in
             99      Zone 3 through 8" are deleted.
             100          (b) In the third sentence, the words "Where required by the building official," and the
             101      word "third" are deleted.
             102          (c) The following sentence is inserted after the third sentence: "The following parties
             103      shall be approved to conduct testing: Parties certified by BPI or RESNET, or licensed
             104      contractors who have completed training provided by Blower Door Test equipment


             105      manufacturers or other comparable training."
             106          (11) In IRC, Section N1102.4.4 (R402.4.4), the last sentence is deleted.
             107          (12) In IRC, Section N1103.2.2 (R403.2.2), the requirements for total leakage testing
             108      are deleted and replaced with the following:
             109          "1. Postconstruction test: Total leakage shall be less than or equal to 10 cfm (283
             110      L/min) per 100 square feet (9.29 m2) of conditioned floor space when tested at a pressure
             111      differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air
             112      handler enclosure. All register boots shall be taped or otherwise sealed during the test.
             113          2. Rough-in test: Total leakage shall be less than or equal to 10 cfm (283 L/min) per
             114      100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of at
             115      least 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler
             116      enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is
             117      not installed at the time of the test, total leakage shall be less than or equal to 7.5 cfm (212
             118      L/min) per 100 square feet (9.29 m2) of conditioned floor area."
             119          (13) In IRC, Section N1103.2.2 (R403.2.2), the exception for total leakage testing is
             120      deleted and replaced with the following: "Exception: The total leakage test is not required for
             121      systems with all air handlers and at least 50% of all ducts (measured by length) located entirely
             122      within the building thermal envelope."
             123          (14) In IRC, Section N1103.2.3 (R403.2.3), the words "or plenums" are deleted.
             124          (15) In IRC, Section N1103.4.2 (R403.4.2), the sentences for "3.", "9.", and the last
             125      sentence are deleted.
             126          (16) In IRC, Section N1103.5 (R403.5), the first sentence is deleted.
             127          (17) IRC, Section N1104.1 (R404.1) and the exception are deleted, and N1104.1.1
             128      (R404.1.1) becomes N1104.1 (R404.1).
             129          (18) In IRC, Table N1105.5.2(1) (R405.5.2(1)), the following changes are made under
             130      the column STANDARD REFERENCE DESIGN:
             131          (a) In the row "Air exchange rate", the words "in Zones 1 and 2, and 3 air changes per
             132      hour in Zones 3 through 8" are deleted.


             133          (b) In the row "Heating systemsf, g", the standard reference design is deleted and
             134      replaced with the following:
             135          "Fuel Type: same as proposed design
             136          Efficiencies:
             137          Electric: air source heat pump with prevailing federal minimum efficiencies
             138          Nonelectric furnaces: natural gas furnace with prevailing federal minimum efficiencies
             139          Nonelectric boilers: natural gas boiler with prevailing federal minimum efficiencies
             140          Capacity: sized in accordance with Section N1103.6"
             141          (c) In the row "Cooling systemsf, h" the words "As proposed" are deleted and replaced
             142      with the following:
             143          "Fuel Type: Electric
             144          Efficiency: in accordance with prevailing federal minimum standards"
             145          (d) In the row "Service water heatingf, g, h, i", the words "As proposed" are deleted and
             146      replaced with the following:
             147          "Fuel Type: same as proposed design
             148          Efficiency: in accordance with prevailing federal minimum standards
             149          Tank Temperature: 120o F"
             150          (e) In the row "Thermal distribution systems" the word "none" is deleted and replaced
             151      with the following: "Thermal distribution system efficiency (DSE) of .080 shall be applied to
             152      both the heating and cooling system efficiencies."
             153          (19) In Table N1105.5.2(2) (R405.5.2(2)), the number "0.80" is inserted under "Forced
             154      air systems" for "Distribution system components located in unconditioned space".
             155          (20) In IRC, Section M1307.2, the words "In Seismic Design Categories D1 and D2"
             156      are deleted.
             157          (21) The RESCheck Software adopted by the United States Department of Energy and
             158      modified to meet the requirements of this section shall be used to verify compliance with this
             159      section. The software shall address the Total UA alternative approach and account for
             160      Equipment Efficiency Trade-offs when applicable per the standard reference design as


             161      amended.
             162          [(3)] (22) IRC, Section M1411.6, is deleted.
             163          [(4) In IRC, Section M1502.4.4.1, the words "25 feet (7,620 mm)" are deleted and
             164      replaced with "35 feet (10,668 mm)".]
             165          Section 3. Section 15A-3-701 is amended to read:
             166     
Part 7. Statewide Amendments to IECC

             167           15A-3-701. General provisions.
             168          The following is adopted as an amendment to the IECC to be applicable statewide[, in
             169      IECC, Section 504.4,]:
             170          (1) In IECC, Section C202, the definition for "CONDITIONED SPACE" is deleted and
             171      replaced with the following: "CONDITIONED SPACE. An area, room or space enclosed
             172      within the building thermal envelope that is directly heated or cooled, or indirectly heated or
             173      cooled by any of the following means:
             174      1. Openings directly into an adjacent conditioned space.
             175      2. An un-insulated floor, ceiling or wall adjacent to a conditioned space.
             176      3. Un-insulated duct, piping or other heat or cooling source within the space."
             177          (2) In IECC, Section C404.4, a new exception is added as follows: "Exception: Heat
             178      traps, other than the arrangement of piping and fittings, shall be prohibited unless a means of
             179      controlling thermal expansion can be ensured as required in the IPC Section 607.3."
             180          (3) In IECC, Section R103.2, all words after the words "herein governed." are deleted
             181      and replaced with the following: "Construction documents include all documentation required
             182      to be submitted in order to issue a building permit."
             183          (4) In IECC, Section R202, the definition for "CONDITIONED SPACE" is deleted and
             184      replaced with the following: "CONDITIONED SPACE. An area, room or space enclosed
             185      within the building thermal envelope that is directly heated or cooled, or indirectly heated or
             186      cooled by any of the following means:
             187      1. Openings directly into an adjacent conditioned space.
             188      2. An un-insulated floor, ceiling or wall adjacent to a conditioned space.


             189      3. Un-insulated duct, piping or other heat or cooling source within the space."
             190          (5) In IECC, Section R303.3, all wording after the first sentence is deleted.
             191          (6) In IECC, Table R402.1.1 and Table R402.1.3, the rows for "climate zone 3",
             192      "climate zone 5 and Marine 4, and climate zone 6" are deleted and replaced and a new footnote
             193      j is added as follows:
             194      "TABLE R402.1.1
             195      INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
             196     

CLIMATE
ZONE


FENESTRATION
U-FACTOR b


SKYLIGHT b
U-FACTOR

GLAZED
FENESTRATION
SHGC b,e


CEILING
R-VALUE
WOOD
FRAME
WALL
R-VALUE

MASS
WALL
R-VALUE I, j


FLOOR
R-VALUE

BASEMENT c
WALL
R-VALUE

SLAB d
R-VALUE
& DEPTH
CRAWL
SPACE c
WALL
R-VALUE
             197      3 0.65 0.65 0.40 30 15 5 19 0 0 5/13
             198      5 and
Marine 4
0.35 0.60 NR 38 19 or 13 +
5h
13 30 g 10/13 10, 2 ft 10/13
             199      6 0.35 0.60 NR 49 19 or 13 +
5h
15 30 g 10/13 10, 4 ft 10/13
             200      j. Log walls complying with ICC400 and with a minimum average wall thickness of 5" or greater shall be permitted in Zones
5-8 when overall window glazing is .31 U-factor or lower, minimum heating equipment efficiency is 90 AFUE (gas) or 84
AFUE (oil), and all other component requirements are met.
             201      TABLE R402.1.3 EQUIVALENT U-FACTORSa
             202     
CLIMATE
ZONE

FENESTRATION
U-FACTOR

SKYLIGHT
U-FACTOR

CEILING
U-FACTOR
FRAME
WALL
U-FACTOR

MASS WALL
U-FACTOR b

FLOOR
U-FACTOR
BASEMENT
WALL
U-FACTOR
CRAWL
SPACE WALL
U-FACTOR
             203      3 0.65 0.65 0.035 0.082 0.141 0.047 0.360 0.136
             204      5 and Marine 4 0.35 0.60 0.030 0.060 0.082 0.033 0.059 0.065
             205      6 0.35 0.60 0.026 0.060 0.060 0.033 0.059 0.065
             206          (7) In IECC, Section R402.2.1, the last sentence is deleted.
             207          (8) In IECC, Section R402.2.2, the last sentence is deleted.
             208          (9) In IECC, Section R402.3.3, the last sentence is deleted.
             209          (10) In IECC, Section R402.3.4, the last sentence is deleted.
             210          (11) In IECC, Section R402.4.1, in the first sentence, the word "and" is deleted and


             211      replaced with the word "or".
             212          (12) In IECC, Section R402.4.1.1, the last sentence is deleted and replaced with the
             213      following: "Where allowed by the building official, the builder may certify compliance to
             214      components criteria for items which may not be inspected during regularly scheduled
             215      inspections."
             216          (13) In IECC, Section R402.4.1.2, the following changes are made:
             217          (a) In the first sentence, the words "in Zones 1 and 2, and 3 air changes per hour in
             218      Zone 3 through 8" are deleted.
             219          (b) In the third sentence, the words "Where required by the building official," and the
             220      word "third" are deleted.
             221          (c) The following sentence is inserted after the third sentence: "The following parties
             222      shall be approved to conduct testing: Parties certified by BPI or RESNET, or licensed
             223      contractors who have completed training provided by Blower Door Test equipment
             224      manufacturers or other comparable training."
             225          (14) In IECC, Section R402.4.4, the last sentence is deleted.
             226          (15) In IECC, Section R403.2.2, the requirements for duct tightness testing are deleted
             227      and replaced with the following:
             228          "1. Postconstruction test: Total leakage shall be less than or equal to 10 cfm (283
             229      L/min) per 100 square feet (9.29 m2) of conditioned floor space when tested at a pressure
             230      differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air
             231      handler enclosure. All register boots shall be taped or otherwise sealed during the test.
             232          2. Rough-in test: Total leakage shall be less than or equal to 10 cfm (283 L/min) per
             233      100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of at
             234      least 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler
             235      enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is
             236      not installed at the time of the test, total leakage shall be less than or equal to 7.5 cfm (212
             237      L/min) per 100 square feet (9.29 m2) of conditioned floor area."
             238          (16) In IECC, Section R403.2.2, the exception for total leakage testing is deleted and


             239      replaced with the following: "Exception: The total leakage test is not required for systems with
             240      all air handlers and at least 50% of all ducts (measured by length) located entirely within the
             241      building thermal envelope."
             242          (17) In IECC, Section R403.2.3, the words "or plenums" are deleted.
             243          (18) In IECC, Section R403.4.2, the sentences for "3." and "9." and the last sentence
             244      are deleted.
             245          (19) In IECC, Section R403.5, the first sentence is deleted.
             246          (20) IECC, Section R404.1 and the exception are deleted, and R404.1.1 becomes
             247      R404.1.
             248          (21) In IECC, Table R405.5.2(1), the following changes are made under the column
             249      STANDARD REFERENCE DESIGN:
             250          (a) In the row "Air exchange rate", the words "in Zones 1 and 2, and 3 air changes per
             251      hour in Zones 3 through 8" are deleted.
             252          (b) In the row "Heating systemsf, g", the standard reference design is deleted and
             253      replaced with the following:
             254          "Fuel Type: same as proposed design
             255          Efficiencies:
             256          Electric: air source heat pump with prevailing federal minimum efficiencies
             257          Nonelectric furnaces: natural gas furnace with prevailing federal minimum efficiencies
             258          Nonelectric boilers: natural gas boiler with prevailing federal minimum efficiencies
             259          Capacity: sized in accordance with Section N1103.6"
             260          (c) In the row "Cooling systemsf, h" the words "As proposed" are deleted and replaced
             261      with the following:
             262          "Fuel Type: Electric
             263          Efficiency: in accordance with prevailing federal minimum standards"
             264          (d) In the row "Service water heatingf, g, h, i", the words "As proposed" are deleted and
             265      replaced with the following:
             266          "Fuel Type: same as proposed design


             267          Efficiency: in accordance with prevailing federal minimum standards
             268          Tank Temperature: 120o F"
             269          (e) In the row "Thermal distribution systems" the word "none" is deleted and replaced
             270      with the following: "Thermal distribution system efficiency (DSE) of .080 shall be applied to
             271      both the heating and cooling system efficiencies."
             272          (22) In IECC, Table R405.5.2(2), the number "0.80" is inserted under "Forced air
             273      systems" for "Distribution system components located in unconditioned space".
             274          (23) The RESCheck Software adopted by the United States Department of Energy and
             275      modified to meet the requirements of this section shall be used to verify compliance with this
             276      section. The software shall address the Total UA alternative approach and account for
             277      Equipment Efficiency Trade-offs when applicable per the standard reference design as
             278      amended.
             279          Section 4. Study on improving residential energy efficiency.
             280          (1) During the 2013 interim, the Architectural Advisory Committee of the Uniform
             281      Building Code Commission, in consultation with the Mechanical Advisory Committee of the
             282      Uniform Building Code Commission, shall study and make recommendations regarding
             283      increasing residential energy performance.
             284          (2) The Architectural Advisory Committee shall present its recommendations to the
             285      Business and Labor Interim Committee no later than the October 2013 interim meeting.
             286          Section 5. Contingent effective date.
             287          This bill takes effect on the first day of the month following the month in which the
             288      Uniform Building Code Commission certifies in writing to the Business and Labor Interim
             289      Committee that the United States Department of Energy has adopted a version of the
             290      RESCheck software that can be used to verify compliance to the requirements of this bill.