H.B. 202
1
2
3
4
5
6
7 LONG TITLE
8 General Description:
9 This bill amends the State Construction Code.
10 Highlighted Provisions:
11 This bill:
12 . adopts the 2012 edition of the International Energy Conservation Code;
13 . modifies certain provisions of the International Energy Conservation Code; and
14 . modifies certain energy provisions of the International Residential Code.
15 Money Appropriated in this Bill:
16 None
17 Other Special Clauses:
18 This bill takes effect on July 1, 2013.
19 Utah Code Sections Affected:
20 AMENDS:
21 15A-2-103, as last amended by Laws of Utah 2012, Chapter 76
22 15A-3-203, as enacted by Laws of Utah 2011, Chapter 14
23 15A-3-701, as enacted by Laws of Utah 2011, Chapter 14
24 Uncodified Material Affected:
25 ENACTS UNCODIFIED MATERIAL
26
27 Be it enacted by the Legislature of the state of Utah:
28 Section 1. Section 15A-2-103 is amended to read:
29 15A-2-103. Specific editions adopted of construction code of a nationally
30 recognized code authority.
31 (1) Subject to the other provisions of this part, the following construction codes are
32 incorporated by reference, and together with the amendments specified in Chapter 3, Statewide
33 Amendments to International Plumbing Code, and Chapter 4, Local Amendments Incorporated
34 as Part of State Construction Code, are the construction standards to be applied to building
35 construction, alteration, remodeling, and repair, and in the regulation of building construction,
36 alteration, remodeling, and repair in the state:
37 (a) the 2009 edition of the International Building Code, including Appendix J, issued
38 by the International Code Council;
39 (b) the 2009 edition of the International Residential Code, issued by the International
40 Code Council;
41 (c) the 2009 edition of the International Plumbing Code, issued by the International
42 Code Council;
43 (d) the 2009 edition of the International Mechanical Code, issued by the International
44 Code Council;
45 (e) the 2009 edition of the International Fuel Gas Code, issued by the International
46 Code Council;
47 (f) the 2011 edition of the National Electrical Code, issued by the National Fire
48 Protection Association;
49 (g) the [
50 the International Code Council;
51 (h) subject to Subsection 15A-2-104 (2), the HUD Code;
52 (i) subject to Subsection 15A-2-104 (1), Appendix E of the 2009 edition of the
53 International Residential Code, issued by the International Code Council; and
54 (j) subject to Subsection 15A-2-104 (1), the 2005 edition of the NFPA 225 Model
55 Manufactured Home Installation Standard, issued by the National Fire Protection Association.
56 (2) Consistent with Title 65A, Chapter 8, Management of Forest Lands and Fire
57 Control, the Legislature adopts the 2006 edition of the Utah Wildland Urban Interface Code,
58 issued by the International Code Council, with the alternatives or amendments approved by the
59 Utah Division of Forestry, as a construction code that may be adopted by a local compliance
60 agency by local ordinance or other similar action as a local amendment to the codes listed in
61 this section.
62 Section 2. Section 15A-3-203 is amended to read:
63 15A-3-203. Amendments to Chapters 6 through 15 of IRC.
64 [
65 [
66
67 (1) In IRC, Section N1101.8 (R103.2), all words after the words "herein governed." are
68 deleted and replaced with the following: "Construction documents include all documentation
69 required to be submitted in order to issue a building permit."
70 (2) In IRC, Section N1101.14 (R303.3), all wording after the first sentence is deleted.
71 (3) In IRC, Table N1102.1.1 (402.1.1) and Table N1102.1.3 (R402.1.3), the rows for
72 "climate zone 3", "climate zone 5 and Marine 4", and "climate zone 6" are deleted and replaced
73 and a new footnote j is added as follows:
74 | "TABLE N1102.1.1 (R402.1.1) | ||||||||||
75 | INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa | ||||||||||
76 |
CLIMATE ZONE |
FENESTRATION U-FACTOR b |
SKYLIGHT b U-FACTOR |
GLAZED FENESTRATION SHGC b,e |
CEILING R-VALUE |
WOOD FRAME WALL R-VALUE |
MASS WALL R-VALUE i,j |
FLOOR R-VALUE |
BASEMENT c WALL R-VALUE |
SLAB d R-VALUE & DEPTH |
CRAWL SPACE c WALL R-VALUE |
77 | 3 | 0.65 | 0.65 | 0.40 | 30 | 15 | 5 | 19 | 0 | 0 | 5/13 |
78 |
5 and Marine 4 |
0.35 | 0.60 | NR | 38 |
19 or 13 + 5h |
13 | 30 g | 10/13 | 10, 2 ft | 10/13 |
79 | 6 | 0.35 | 0.60 | NR | 49 |
19 or 13 + 5h |
15 | 30 g | 10/13 | 10, 4 ft | 10/13 |
80 |
j. Log walls complying with ICC400 and with a minimum average wall thickness of 5 or greater shall be permitted in Zones 5-8 when overall window glazing is .31 U-factor or lower, minimum heating equipment efficiency is 90 AFUE (gas) or 84 AFUE (oil), and all other component requirements are met. |
81 | TABLE N1102.1.3 (R402.1.3) | ||||||||
82 | EQUIVALENT U-FACTORSa | ||||||||
83 |
CLIMATE ZONE |
FENESTRATION U-FACTOR |
SKYLIGHT U-FACTOR |
CEILING U-FACTOR |
FRAME WALL U-FACTOR |
MASS WALL U-FACTOR b |
FLOOR U-FACTOR |
BASEMENT WALL U-FACTOR |
CRAWL SPACE WALL U-FACTOR |
84 | 3 | 0.65 | 0.65 | 0.035 | 0.082 | 0.141 | 0.047 | 0.360 | 0.136 |
85 |
5 and Marine 4 |
0.35 | 0.60 | 0.030 | 0.060 | 0.082 | 0.033 | 0.059 | 0.065 |
86 | 6 | 0.35 | 0.60 | 0.026 | 0.060 | 0.060 | 0.033 | 0.059 | 0.065 |
88 (5) In IRC, Section N1102.2.2 (R402.2.2), the last sentence is deleted.
89 (6) In IRC, Section N1102.3.3 (R402.3.3), the last sentence is deleted.
90 (7) In IRC, Section N1102.3.4 (R402.3.4), the last sentence is deleted.
91 (8) In IRC, Section N1102.4.1 (R402.4.1), in the first sentence, the word "and" is
92 deleted and replaced with the word "or".
93 (9) In IRC, Section N1102.4.1.1 (R402.4.1.1), the last sentence is deleted and replaced
94 with the following: "Where allowed by the building official, the builder may certify compliance
95 to components criteria for items which may not be inspected during regularly scheduled
96 inspections."
97 (10) In IRC, Section N1102.4.1.2 (R402.4.1.2), the following changes are made:
98 a. In the first sentence, the words "in Zones 1 and 2, and 3 air changes per hour in Zone 3
99 through 8" are deleted.
100 b. In the third sentence, the words "Where required by the building official," and the word
101 "third" are deleted.
102 c. The following sentence is inserted after the third sentence: "The following parties shall be
103 approved to conduct testing: Parties certified by BPI or RESNET, or licensed contractors who
104 have completed training provided by Blower Door Test equipment manufacturers or other
105 comparable training."
106 (11) In IRC, Section N1102.4.4 (R402.4.4), the last sentence is deleted.
107 (12) In IRC, Section N1103.2.2 (R403.2.2), the requirements for duct tightness testing
108 are deleted and replaced with the following:
109 "1. Postconstruction test: Total leakage shall be less than or equal to 10 cfm (283
110 L/min) per 100 square feet (9.29 m2) of conditioned floor space when tested at a pressure
111 differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air
112 handler enclosure. All register boots shall be taped or otherwise sealed during the test.
113 2. Rough-in test: Total leakage shall be less than or equal to 10 cfm (283 L/min) per
114 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of at
115 least 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler
116 enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is
117 not installed at the time of the test, total leakage shall be less than or equal to 7.5 cfm (212
118 L/min) per 100 square feet (9.29 m2) of conditioned floor area."
119 (13) In IRC, Section N1103.2.2 (R403.2.2), the exception for duct tightness testing is
120 deleted and replaced with the following: "Exception: The total leakage test is not required for
121 systems with all air handlers and at least 50% of all ducts (measured by length) located entirely
122 within the building thermal envelope."
123 (14) In IRC, Section N1103.2.3 (R403.2.3), the words "or plenums" are deleted.
124 (15) In IRC, Section N1103.4.2 (R403.4.2), the sentences for "3.", "9.", and the last
125 sentence are deleted.
126 (16) In IRC, Section N1103.5 (R403.5), the first sentence is deleted.
127 (17) IRC, Section N1104.1 (R404.1) and the exception are deleted, and N1104.1.1
128 (R404.1.1) becomes N1104.1 (R404.1).
129 (18) In IRC, Table N1105.5.2(1) (R405.5.2(1)), the following changes are made under
130 the column STANDARD REFERENCE DESIGN:
131 a. In the row "Air exchange rate", the words "in Zones 1 and 2, and 3 air changes per hour in
132 Zones 3 through 8" are deleted.
133 b. In the row "Heating systemsf, g", the standard reference design is deleted and replaced with
134 the following:
135 "Fuel Type: same as proposed design
136 Efficiencies:
137 Electric: air source heat pump with prevailing federal minimum efficiencies
138 Nonelectric furnaces: natural gas furnace with prevailing federal minimum efficiencies
139 Nonelectric boilers: natural gas boiler with prevailing federal minimum efficiencies
140 Capacity: sized in accordance with Section N1103.6"
141 c. In the row "Cooling systemsf, h" the words "As proposed" are deleted and replaced with the
142 following:
143 "Fuel Type: Electric
144 Efficiency: in accordance with prevailing federal minimum standards"
145 d. In the row "Service water heatingf, g, h, i", the words "As proposed" are deleted and replaced
146 with the following:
147 "Fuel Type: same as proposed design
148 Efficiency: in accordance with prevailing federal minimum standards
149 Tank Temperature: 120o F"
150 e. In the row "Thermal distribution systems" the word "none" is deleted and replaced with the
151 following: "Thermal distribution system efficiency (DSE) of .080 shall be applied to both the
152 heating and cooling system efficiencies."
153 (19) In Table N1105.5.2(2) (R405.5.2(2)), the number "0.80" is inserted under "Forced
154 air systems" for "Distribution system components located in unconditioned space".
155 (20) In IRC, Section M1307.2, the words "In Seismic Design Categories D1 and D2"
156 are deleted.
157 [
158 [
159
160 Section 3. Section 15A-3-701 is amended to read:
161
162 15A-3-701. General provisions.
163 The following is adopted as an amendment to the IECC to be applicable statewide[
164
165 (1) In IECC, Section C202, the definition for "CONDITIONED SPACE" is deleted and
166 replaced with the following: "CONDITIONED SPACE. An area, room or space enclosed
167 within the building thermal envelope that is directly heated or cooled, or indirectly heated or
168 cooled by any of the following means:
169 1. Openings directly into an adjacent conditioned space.
170 2. An un-insulated floor, ceiling or wall adjacent to a conditioned space.
171 3. Un-insulated duct, piping or other heat or cooling source within the space."
172 (2) In IECC, Section C404.4, a new exception is added as follows: "Exception: Heat
173 traps, other than the arrangement of piping and fittings, shall be prohibited unless a means of
174 controlling thermal expansion can be ensured as required in the IPC Section 607.3."
175 (3) In IECC, Section R103.2, all words after the words "herein governed." are deleted
176 and replaced with the following: "Construction documents include all documentation required
177 to be submitted in order to issue a building permit."
178 (4) In IECC, Section R202, the definition for "CONDITIONED SPACE" is deleted and
179 replaced with the following: "CONDITIONED SPACE. An area, room or space enclosed
180 within the building thermal envelope that is directly heated or cooled, or indirectly heated or
181 cooled by any of the following means:
182 1. Openings directly into an adjacent conditioned space.
183 2. An un-insulated floor, ceiling or wall adjacent to a conditioned space.
184 3. Un-insulated duct, piping or other heat or cooling source within the space."
185 (5) In IECC, Section R303.3, all wording after the first sentence is deleted.
186 (6) In IECC, Table R402.1.1 and Table R402.1.3, the rows for "climate zone 3",
187 "climate zone 5 and Marine 4, and climate zone 6" are deleted and replaced and a new footnote
188 j is added as follows:
189 | "TABLE R402.1.1 | ||||||||||
190 | INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa | ||||||||||
191 |
CLIMATE ZONE |
FENESTRATION U-FACTOR b |
SKYLIGHT b U-FACTOR |
GLAZED FENESTRATION SHGC b,e |
CEILING R-VALUE |
WOOD FRAME WALL R-VALUE |
MASS WALL R-VALUE I, j |
FLOOR R-VALUE |
BASEMENT c WALL R-VALUE |
SLAB d R-VALUE & DEPTH |
CRAWL SPACE c WALL R-VALUE |
192 | 3 | 0.65 | 0.65 | 0.40 | 30 | 15 | 5 | 19 | 0 | 0 | 5/13 |
193 |
5 and Marine 4 |
0.35 | 0.60 | NR | 38 |
19 or 13 + 5h |
13 | 30 g | 10/13 | 10, 2 ft | 10/13 |
194 | 6 | 0.35 | 0.60 | NR | 49 |
19 or 13 + 5h |
15 | 30 g | 10/13 | 10, 4 ft | 10/13 |
195 |
j. Log walls complying with ICC400 and with a minimum average wall thickness of 5" or greater shall be permitted in Zones 5-8 when overall window glazing is .31 U-factor or lower, minimum heating equipment efficiency is 90 AFUE (gas) or 84 AFUE (oil), and all other component requirements are met. |
196 | TABLE R402.1.3 EQUIVALENT U-FACTORSa | ||||||||
197 |
CLIMATE ZONE |
FENESTRATION U-FACTOR |
SKYLIGHT U-FACTOR |
CEILING U-FACTOR |
FRAME WALL U-FACTOR |
MASS WALL U-FACTOR b |
FLOOR U-FACTOR |
BASEMENT WALL U-FACTOR |
CRAWL SPACE WALL U-FACTOR |
198 | 3 | 0.65 | 0.65 | 0.035 | 0.082 | 0.141 | 0.047 | 0.360 | 0.136 |
199 | 5 and Marine 4 | 0.35 | 0.60 | 0.030 | 0.060 | 0.082 | 0.033 | 0.059 | 0.065 |
200 | 6 | 0.35 | 0.60 | 0.026 | 0.060 | 0.060 | 0.033 | 0.059 | 0.065 |
202 (8) In IECC, Section R402.2.2, the last sentence is deleted.
203 (9) In IECC, Section R402.3.3, the last sentence is deleted.
204 (10) In IECC, Section R402.3.4, the last sentence is deleted.
205 (11) In IECC, Section R402.4.1, in the first sentence, the word "and" is deleted and
206 replaced with the word "or".
207 (12) In IECC, Section R402.4.1.1, the last sentence is deleted and replaced with the
208 following: "Where allowed by the building official, the builder may certify compliance to
209 components criteria for items which may not be inspected during regularly scheduled
210 inspections."
211 (13) In IECC, Section R402.4.1.2, the following changes are made:
212 a. In the first sentence, the words "in Zones 1 and 2, and 3 air changes per hour in Zone 3
213 through 8" are deleted.
214 b. In the third sentence, the words "Where required by the building official," and the word
215 "third" are deleted.
216 c. The following sentence is inserted after the third sentence: "The following parties shall be
217 approved to conduct testing: Parties certified by BPI or RESNET, or licensed contractors who
218 have completed training provided by Blower Door Test equipment manufacturers or other
219 comparable training."
220 (14) In IECC, Section R402.4.4, the last sentence is deleted.
221 (15) In IECC, Section R403.2.2, the requirements for duct tightness testing are deleted
222 and replaced with the following:
223 "1. Postconstruction test: Total leakage shall be less than or equal to 10 cfm (283
224 L/min) per 100 square feet (9.29 m2) of conditioned floor space when tested at a pressure
225 differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air
226 handler enclosure. All register boots shall be taped or otherwise sealed during the test.
227 2. Rough-in test: Total leakage shall be less than or equal to 10 cfm (283 L/min) per
228 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of at
229 least 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler
230 enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is
231 not installed at the time of the test, total leakage shall be less than or equal to 7.5 cfm (212
232 L/min) per 100 square feet (9.29 m2) of conditioned floor area."
233 (16) In IECC, Section R403.2.2, the exception for total leakage testing is deleted and
234 replaced with the following: "Exception: The total leakage test is not required for systems with
235 all air handlers and at least 50% of all ducts (measured by length) located entirely within the
236 building thermal envelope."
237 (17) In IECC, Section R403.2.3, the words "or plenums" are deleted.
238 (18) In IECC, Section R403.4.2, the sentences for "3." and "9." and the last sentence
239 are deleted.
240 (19) In IECC, Section R403.5, the first sentence is deleted.
241 (20) IECC, Section R404.1 and the exception are deleted, and R404.1.1 becomes
242 R404.1.
243 (21) In IECC, Table R405.5.2(1), the following changes are made under the column
244 STANDARD REFERENCE DESIGN:
245 a. In the row "Air exchange rate", the words "in Zones 1 and 2, and 3 air changes per hour in
246 Zones 3 through 8" are deleted.
247 b. In the row "Heating systemsf, g", the standard reference design is deleted and replaced with
248 the following:
249 "Fuel Type: same as proposed design
250 Efficiencies:
251 Electric: air source heat pump with prevailing federal minimum efficiencies
252 Nonelectric furnaces: natural gas furnace with prevailing federal minimum efficiencies
253 Nonelectric boilers: natural gas boiler with prevailing federal minimum efficiencies
254 Capacity: sized in accordance with Section N1103.6"
255 c. In the row "Cooling systemsf, h" the words "As proposed" are deleted and replaced with the
256 following:
257 "Fuel Type: Electric
258 Efficiency: in accordance with prevailing federal minimum standards"
259 d. In the row "Service water heatingf, g, h, i", the words "As proposed" are deleted and replaced
260 with the following:
261 "Fuel Type: same as proposed design
262 Efficiency: in accordance with prevailing federal minimum standards
263 Tank Temperature: 120o F"
264 e. In the row "Thermal distribution systems" the word "none" is deleted and replaced with the
265 following: "Thermal distribution system efficiency (DSE) of .080 shall be applied to both the
266 heating and cooling system efficiencies."
267 (22) In IECC, Table R405.5.2(2), the number "0.80" is inserted under "Forced air
268 systems" for "Distribution system components located in unconditioned space".
269 Section 4. Study on improving residential energy efficiency.
270 (1) During the 2013 interim, the Architectural Advisory Committee of the Uniform
271 Building Code Commission, in consultation with the Mechanical Advisory Committee of the
272 Uniform Building Code Commission, shall study and make recommendations on ways to
273 increase residential energy efficiency by 5% by January 1, 2015.
274 (2) The Architectural Advisory Committee shall present its recommendations to the
275 Business and Labor Interim Committee no later than the October 2013 interim meeting.
276 Section 5. Effective date.
277 This bill takes effect on July 1, 2013.
Legislative Review Note