H.B. 58

             1     

CHANGES TO AMENDMENTS INCORPORATED INTO STATE

             2     
CONSTRUCTION CODE

             3     
2012 GENERAL SESSION

             4     
STATE OF UTAH

             5     
Chief Sponsor: Jeremy A. Peterson

             6     
Senate Sponsor: ____________

             7     
             8      LONG TITLE
             9      General Description:
             10          This bill modifies a provision amending the state construction code.
             11      Highlighted Provisions:
             12          This bill:
             13          .    modifies a provision requiring an engineer evaluation of certain buildings built
             14      before 1975;
             15          .    eliminates a requirement that the evaluation occur when the building is undergoing
             16      reroofing or an alteration of or repair to certain features; and
             17          .    replaces that requirement with a requirement that the evaluation occur when the
             18      building is undergoing structural alterations or repairs, and specifies what is not
             19      included in structural alterations or repairs.
             20      Money Appropriated in this Bill:
             21          None
             22      Other Special Clauses:
             23          None
             24      Utah Code Sections Affected:
             25      AMENDS:
             26          15A-3-113, as enacted by Laws of Utah 2011, Chapter 14
             27     


             28      Be it enacted by the Legislature of the state of Utah:
             29          Section 1. Section 15A-3-113 is amended to read:
             30           15A-3-113. Amendments to Chapters 32 through 35 of IBC.
             31          (1) A new section IBC, Section 3401.6, is added as follows: "3401.6 Parapet bracing,
             32      wall anchors, and other appendages. Buildings constructed before 1975 shall have parapet
             33      bracing, wall anchors, and appendages such as cornices, spires, towers, tanks, signs, statuary,
             34      etc. evaluated by a licensed engineer when [said] the building is undergoing [reroofing, or
             35      alteration of or repair to said feature.] structural alterations or structural repairs. Reroofing or
             36      water membrane replacement may not be considered a structural alteration or repair for
             37      purposes of this section. Such parapet bracing, wall anchors, and appendages shall be
             38      evaluated in accordance with 75% of the seismic forces as specified in Section 1613. When
             39      allowed by the local building official, alternate methods of equivalent strength as referenced in
             40      an approved code under Utah Code, Subsection 15A-1-204 (6)(a), will be considered when
             41      accompanied by engineer-sealed drawings, details, and calculations. When found to be
             42      deficient because of design or deteriorated condition, the engineer's recommendations to
             43      anchor, brace, reinforce, or remove the deficient feature shall be implemented.
             44      EXCEPTIONS:
             45      1. Group R-3 and U occupancies.
             46      2. Unreinforced masonry parapets need not be braced according to the above stated provisions
             47      provided that the maximum height of an unreinforced masonry parapet above the level of the
             48      diaphragm tension anchors or above the parapet braces shall not exceed one and one-half times
             49      the thickness of the parapet wall. The parapet height may be a maximum of two and one-half
             50      times its thickness in other than Seismic Design Categories D, E, or F."
             51          (2) IBC, Section 3408.4, is deleted and replaced with the following: "3408.4 Change in
             52      Occupancy. When a change in occupancy results in a structure being reclassified to a higher
             53      Occupancy Category (as defined in Table 1604.5), or when such change of occupancy results in
             54      a design occupant load increase of 100% or more, the structure shall conform to the seismic
             55      requirements for a new structure.
             56      Exceptions:
             57      1. Specific seismic detailing requirements of this code or ASCE 7 for a new structure shall not
             58      be required to be met where it can be shown that the level of performance and seismic safety is


             59      equivalent to that of a new structure. Such analysis shall consider the regularity, overstrength,
             60      redundancy, and ductility of the structure within the context of the existing and retrofit (if any)
             61      detailing providing. Alternatively, the building official may allow the structure to be upgraded
             62      in accordance with referenced sections as found in an approved code under Utah Code,
             63      Subsection 15A-1-204 (6)(a).
             64      2. When a change of use results in a structure being reclassified from Occupancy Category I or
             65      II to Occupancy Category III and the structure is located in a seismic map area where SDS is
             66      less than 0.33, compliance with the seismic requirements of this code and ASCE 7 are not
             67      required.
             68      3. Where design occupant load increase is less than 25 occupants and the Occupancy Category
             69      does not change."
             70          (3) In IBC, Section 3411.1, the exception is deleted and replaced with the following:
             71      "Exception: Type B dwelling or sleeping units required by Section 1107 of this code are not
             72      required to be provided in existing buildings and facilities unless being altered or undergoing a
             73      change of occupancy classification."
             74          (4) The following referenced standard is added under NFPA in IBC, Chapter 35:
             75      "Number Title Referenced in code section number
             76      720-09 Standard for the Installation of
Carbon Monoxide (CO) Detection
and Warning Equipment
907.9"
             77          (5) The following referenced standard is added under UL in IBC, Chapter 35:
             78      "Number Title Referenced in code section number
             79      2034-2008 Standard of Single- and
Multiple-station Carbon Monoxide
Alarms
907.9"
             80          (6) In IBC, Chapter 35, NFPA referenced standard 10-07 is deleted and replaced with
             81      the following:
             82      "Number Title Referenced in code section number
             83      10-10 Portable Fire Extinguishers 906.2, 906.3.2, 906.3.4, Table
906.3(1), Table 906.3(2)"
             84          (7) In IBC, Chapter 35, NFPA referenced standard 11-05 is deleted and replaced with
             85      the following:


             86      "Number Title Referenced in code section number
             87      11-10 Low Expansion Foam 904.7"
             88          (8) In IBC, Chapter 35, NFPA referenced standard 12-05 is deleted and replaced with
             89      the following:
             90      "Number Title Referenced in code section number
             91      12-08 Carbon Dioxide Extinguishing
Systems
904.8, 904.11"
             92          (9) In IBC, Chapter 35, NFPA referenced standard 12A-04 is deleted and replaced with
             93      the following:
             94      "Number Title Referenced in code section number
             95      12A-09 Halon 1301 Fire Extinguishing
Systems
904.9"
             96          (10) In IBC, Chapter 35, NFPA referenced standard 13-07 is deleted and replaced with
             97      the following:
             98      "Number Title Referenced in code section number
             99      13-10 Installation of Sprinkler Systems 708.2, 903.3.1.1, 903.3.2,
903.3.5.1.1, 903.3.5.3, 904.11,
905.3.4, 907.6.3, 1613.3"
             100          (11) In IBC, Chapter 35, NFPA referenced standard 13D-07 is deleted and replaced
             101      with the following:
             102      "Number Title Referenced in code section number
             103      13D-10 Installation of Sprinkler Systems in
One- and Two-family Dwellings and
Manufactured Homes
903.3.1.3, 903.3.5.1.1"
             104          (12) In IBC, Chapter 35, NFPA referenced standard 13R-07 is deleted and replaced
             105      with the following:


             106      "Number Title Referenced in code section number
             107      13R-10 Installation of Sprinkler Systems in
Residential Occupancies Up to and
Including Four Stories in Height
903.3.1.2, 903.3.5.1.1, 903.3.5.1.2,
903.4"
             108          (13) In IBC, Chapter 35, NFPA referenced standard 14-07 is deleted and replaced with
             109      the following:
             110      "Number Title Referenced in code section number
             111      14-10 Installation of Standpipe and Hose
System
905.2, 905.3.4, 905.6.2, 905.8"
             112          (14) In IBC, Chapter 35, NFPA referenced standard 17-02 is deleted and replaced with
             113      the following:
             114      "Number Title Referenced in code section number
             115      17-09 Dry chemical Extinguishing Systems 904.5, 904.11"
             116          (15) In IBC, Chapter 35, NFPA referenced standard 17A-02 is deleted and replaced
             117      with the following:
             118      "Number Title Referenced in code section number
             119      17A-09 Wet Chemical Extinguishing System 904.5, 904.11"
             120          (16) In IBC, Chapter 35, NFPA referenced standard 20-07 is deleted and replaced with
             121      the following:
             122      "Number Title Referenced in code section number
             123      20-10 Installation of Stationary Pumps for
Fire Protection
913.1, 913.2.1, 913.5"
             124          (17) In IBC, Chapter 35, NFPA referenced standard 72-07 is deleted and replaced with
             125      the following:
             126      "Number Title Referenced in code section number
             127      72-10 National Fire Alarm Code 901.6, 903.4.1, 904.3.5, 907.2,
907.2.5, 907.2.11, 907.2.13.2,
907.3, 907.3.3, 907.3.4,
907.5.2.1.2, 907.5.3.3, 907.6,
907.6.1, 907.6.5, 907.7, 907.7.1,
907.7.2, 911.1.5, 3006.5, 3007.6"
             128          (18) In IBC, Chapter 35, NFPA referenced standard 92B-05 is deleted and replaced
             129      with the following:
             130      "Number Title Referenced in code section number
             131      92B-09 Smoke Management Systems in
Malls, Atria and Large Spaces
909.8"
             132          (19) In IBC, Chapter 35, NFPA referenced standard 101-06 is deleted and replaced
             133      with the following:
             134      "Number Title Referenced in code section number
             135      101-09 Line Safety Code 1028.6.2"
             136          (20) In IBC, Chapter 35, NFPA referenced standard 110-05 is deleted and replaced
             137      with the following:
             138      "Number Title Referenced in code section number
             139      110-10 Emergency and Standby Power
Systems
2702.1"





Legislative Review Note